English (GB)
21
5.
High current and
power
consumption.
a)
Wrong voltage supply or supply
failure.
Call an electrician.
b)
Power supply cable is faulty.
Call an electrician.
c)
Control system is faulty.
Call an electrician.
d)
Impeller cannot rotate freely.
Clean the impeller and check manually
that it can rotate freely.
e)
Stator windings are faulty.
Contact Grundfos.
f)
Pump runs on two phases.
1. Check the electrical connections.
2. Replace faulty fuses.
3. Call an electrician.
g)
Internal parts are worn.
Contact Grundfos.
h)
Faulty motor or gearbox roller
bearings.
Contact Grundfos.
Fault
Cause
Remedy
Содержание SRG 60 Hz
Страница 1: ...SRG 50 Hz Installation and operating instructions GRUNDFOS INSTRUCTIONS...
Страница 2: ...2...
Страница 132: ...GR 132 2...
Страница 133: ...GR 133 3 3 1 3 2 Grundfos Grundfos 3 3 4 4 1 min 1 ABOVE 1 5 1 1 TM02 9478 0215 H min H Above...
Страница 144: ...GR 144 7 2 Grundfos Grundfos 7 3 6...
Страница 147: ...GR 147 4 a Grundfos b c Grundfos d 5 a b c d e Grundfos f 1 2 3 g Grundfos h Grundfos...
Страница 312: ...RU 312 2...
Страница 313: ...RU 313 3 3 1 3 2 Grundfos Grundfos 3 3 12 4 4 1 Hmin 1 HABOVE 1 5 1 1 TM02 9478 0215 H min H Above...
Страница 316: ...RU 316 8 17 18 19 20 18 9 9 21 20 22 TM02 4938 1802 15 17 TM04 3929 2813 20 18 31 B...
Страница 321: ...RU 321 4 6 15 5 50 75 2 16 7 3 7 2 16 1 4 4 3 2 3 TM02 9480 2704 1 2 3 IA IN L1 L2 L3 N PE 1 3 2 2 TM02 9479 2704 1 3 2...
Страница 325: ...RU 325 7 2 Grundfos Grundfos 7 3...
Страница 327: ...RU 327 8 1 a b c d e Grundfos f g h 4 5 3 i Grundfos j Grundfos 2 a Grundfos b c 4 5 3 d Grundfos e Grundfos...
Страница 328: ...RU 328 3 a b 1 2 3 c Grundfos d 4 a Grundfos b c Grundfos d 5 a b c d e Grundfos f 1 2 3 g Grundfos h Grundfos...
Страница 405: ...CN 405 2 3 3 1 3 2 3 3...
Страница 416: ...CN 416 7 2 7 3 6...
Страница 418: ...CN 418 8 1 a b c d e f g h 4 5 3 i j 2 a b c 4 5 3 d e 3 a b 1 2 3 c d 4 a b c d 5 a b c d e f 1 2 3 g h...