background image

Page 2

How to Install the Grundfos SQFlex Submersible Pump

To

Ground

LA302DC
Lightning
Arrestor

If the cable run to the controller
is more that 30 feet, you may
want to install a “Weatherproof
Outlet Box with Blank Cover”
where you can connect the
expensive sub pump cable to
economical outdoor Romex
cable.

To

Ground

Use Underwater
Cable Splices here
to join the pump
cable with the
submersible cable.

Make sure the dry run
switch is underwater.
It’s a little grey bulb
on  the pump cable.

Extension
Cable with
connectors

Romex, 10 gauge,

outdoor grade,

2 conductors

plus ground wire

Float Switch
in Tank

250 Watt Solar

Module

250 Watt Solar

Module

18 gauge

2 conductor

cable

CU-200

Box

©2015 High Lifter Pump Service 707-923-2109 [email protected]