4. Technical data / Dimensions
4.1 Technical data
Data
60-10
120-7
200-4
Mechanical
data
Turn-down ratio (setting range)
[1:X]
800
800
800
Max. dosing capacity
[l/h]
60
120
200
[gph]
15.8
32
52.8
Min. dosing capacity
[l/h]
0.075
0.15
0.25
[gph]
0.0197
0.04
0.066
Max. operating pressure
[bar]
10
7
4
[psi]
145
101
58
Max. stroke frequency
[strokes/min]
196
188
188
Stroke volume
[ml]
5.56
11.58
19.3
Accuracy of repeatability
4)
[%]
5 SP + 0.1 FS
Max. suction lift during operation
1)
[m]
3
Max. suction lift when priming with wet valves
1)
[m]
1.5
Min. pressure difference between inlet and
outlet side
[bar]
1
[psi]
14.5
Max. inlet pressure, inlet side
[bar]
2
[psi]
29
Max. viscosity with spring-loaded valves
2)
[mPas]
(= cP)
1000
1000
500
Max. viscosity without spring-loaded valves
2)
[mPas]
(= cP)
100
Min. internal hose/pipe diameter inlet/outlet
side
1), 3)
[mm]
19
Min. internal hose/pipe diameter inlet/outlet
side (high viscosity)
3)
[mm]
19
Min. / Max. liquid temperature (PVDF, SS)
[°C]
0 / 50
Min. / Max. liquid temperature (PVC)
[°C]
0 / 40
Min. / Max. ambient temperature
[°C]
0 / 45
Min. / Max. storage temperature (PVDF, SS)
[°C]
-20 / 70
Min. / Max. storage temperature (PVC)
[°C]
-20 / 45
Max. relative humidity (non-condensing)
[%]
90
Max. altitude above sea level
[m]
2000
Electrical
data
Voltage
[V]
100-240 V ± 10 %, 50/60 Hz
Length of mains cable
[m]
1.5
Max. inrush current for 2 ms (100 V)
[A]
35
Max. inrush current for 2 ms (240 V)
[A]
70
Max. power consumption P
1
[W]
62
Enclosure class
IP65, Nema 4X
Electrical safety class
I
Pollution degree
2