English (GB)
10
3.6 Brine tank capacities
3.7 Temperatures and humidity
* For storage temperatures below +5 °C, the whole system
including water softener, lines and external components must
not contain any water.
3.8 Materials
3.9 Salt specifications
Use food-grade granular/pellet salt (98.5 % NaCl) according to
EN 14805 type 2 with following minimum requirements:
3.10 Water softener
3.10.1 General data
3.10.2 Hardness ranges and meter discs
* built in at factory
Brine tank
Salt capacity [kg]
Gravel requirement
[kg]
95714317
150
25
95714318
300
50
95714319
500
75
95714320
1000
175
Max. relative humidity, non-condensing
[%]
80
Permissible ambient temperature
[°C]
+5 to +40
Permissible mains water operating
temperature
[°C]
+10 to +20
Transport and storage temperature, drained
and not connected*
[°C]
-5 to +50
Max. altitude above sea level
[m]
2000
System frame
PP
Chamber covers
PVC clear
Electrolyser cell tube
PVC-U clear
Internal pipes
PVC-U grey
Seals
EPDM
Pump dosing heads
PVC-U grey
Parameter
Symbol
Max. mass fraction
for dry salt [mg/kg]
Iron
Fe
10.0
Manganese
Mn
10.0
Bromide
Br
100.0
Calcium
Ca
100.0
Magnesium
Mg
100.0
Regeneration
Salt used
[kg]
0.45
Regeneration time
[min]
11
Water used per cycle
[l]
18.9
General data (filled with resin beads)
Shipping weight
[kg]
18
Inlet/Outlet connections
[inch]
1/4 BSP
(male)
Meter disc
number
Hardness range
Litres between
regeneration
cycles
ppm CaCO
3
(US)
°dH
(Germany)
2
92-181
4-8
1103
3
182-269
8-11
736
4*
270-356
11-15
552
5
357-442
15-19
441
6
443-524
19-23
368
7
525-607
23-27
315