7. Storing and handling the product
The pump can be transported in a vertical or horizontal position.
Make sure that it cannot roll or fall over.
7.1 Storing the product
During long periods of storage, protect the pump against moisture
and heat.
If the pump has been in use, change the motor liquid before
storage. See section
10.3 Checking and changing the motor oil
After a long period of storage, inspect the pump before putting it
into operation. Make sure that the impeller can rotate freely. Pay
special attention to the shaft seals, O-rings, motor oil and cable
entry.
7.2 Transporting the product
Make sure that all lifting equipment is rated for the purpose.
Check the lifting equipment for damage before making any
attempts to lift the pump. Do not exceed the rating data under any
circumstances. For pump weights, see the pump nameplate,
section
.
The polyurethane-embedded plug prevents water from entering
the motor via the motor cable.
7.3 Lifting the product
The SEG AUTO
ADAPT
pumps weigh between 38 kg and 65 kg
without accessories. It is therefore essential to use the correct
lifting equipment.
When lifting the pump, use the correct lifting point to keep the
pump balanced. Place the lifting chain hook in point A for auto-
coupling installations and in point B for other installations. See
fig.
.
Fig. 5
Lifting points
7.4 Contaminated products
See section
2. Returning the product for service
WARNING
Instable pump
Death or serious personal injury
- Always lift the pump by its lifting bracket or by
means of a forklift if the pump is fixed on a pallet.
Never lift the pump by means of the motor cable or
the hose/pipe.
Rate all lifting equipment for the purpose and check it
for damage before making any attempts to lift the
pump. Do not exceed the lifting equipment rating
under any circumstances.
TM
06 006
6 481
3
CAUTION
Biological hazard
Minor or moderate personal injury
- If a pump has been used for a liquid which is
injurious to health or toxic, the pump will be
classified as contaminated.
Содержание seg autoadapt
Страница 1: ...SEG AUTOAdapt 0 9 4 0 kW DIN 50 Hz Service instructions GRUNDFOS INSTRUCTIONS ...
Страница 19: ...English GB 19 13 Drawings 13 1 Sectional drawing 0 9 to 1 5 kW TM06 6109 0716 6a Single phase pump only ...
Страница 20: ...English GB 20 13 2 Exploded view 0 9 to 1 5 kW TM06 5750 0316 ...
Страница 21: ...English GB 21 13 3 Sectional drawing 2 6 to 4 0 kW TM06 6111 0716 6a ...
Страница 22: ...English GB 22 13 4 Exploded view 2 6 to 4 0 kW Fig 21 SEG AUTOADAPT 2 6 4 kW TM06 5770 0316 ...