background image

English (GB)

3

1.3 Notes

The symbols and notes below may appear in Grundfos 
installation and operating instructions, safety instructions and 
service instructions.

2. Receiving the product

2.1 Inspecting the product

Check that the product received is in accordance with the order.
Check that the voltage and frequency of the product match the 
voltage and frequency of the installation site. See section 

6.4.1 Nameplate

.

2.2 Scope of delivery

The box contains the following items:
• 1 Grundfos SCALA2 pump
• 1 quick guide
• 1 safety instructions booklet.

3. Installing the product

3.1 Location

The pump can be installed indoors or outdoors, but it must not be 
exposed to frost.
We recommend that you install the pump near a drain or in a drip 
tray connected to a drain in order to lead away possible 
condensation from cold surfaces.

3.1.1 Minimum space

The pump requires a minimum space of 430 x 215 x 325 mm (17 
x 8.5 x 12.8 inches).
Even though the pump does not require much space, we 
recommend that you leave enough space for service and 
maintenance access.

3.1.2 Installing the product in frosty environment

Protect the pump from freezing if it is to be installed outdoors 
where frost may occur.

3.2 System sizing

The pump is factory-set to 3 bar (44 psi) outlet pressure which 
can be adjusted according to the system in which it is 
incorporated.
The tank precharge pressure is 1.25 bar (18 psi).
In case of suction lift of more than six metres, the pipe resistance 
on the outlet side must be at least two metres water column or 3 
psi at any given flow in order to obtain optimum operation.

3.3 Mechanical installation

3.3.1 Positioning the product

Always mount the pump on the base plate in a horizontal position 
with a maximum inclination angle of ± 5 °.

3.3.2 Foundation

Fasten the pump to a solid horizontal foundation by means of 
screws through the holes in the base plate. See figs 

1

 and 

2

Fig. 1

Horizontal foundation

Fig. 2

Base plate

Observe these instructions for explosion-proof 
products.

A blue or grey circle with a white graphical symbol 
indicates that an action must be taken.

A red or grey circle with a diagonal bar, possibly with 
a black graphical symbol, indicates that an action 
must not be taken or must be stopped.

If these instructions are not observed, it may result in 
malfunction or damage to the equipment.

Tips and advice that make the work easier.

Install the pump in such a way that no undesirable 
collateral damage can arise due to leakage.
If the unlikely event of an internal leakage occurs, the 
liquid will be drained through the bottom of the pump.

Make sure that the system in which the pump is 
incorporated is designed for the maximum pump 
pressure.

DANGER
Electric shock

Death or serious personal injury
- Switch off the power supply before starting any 

work on the product. Make sure that the power 
supply cannot be accidentally switched on.

TM

06

 5

729

 53

15

 

TM

06

 3

809

 1

015

[mm (inches)]

A

181 (7.13)

B

130 (5.12)

C

144 (5.67)

B

A

C

Содержание SCALA Series

Страница 1: ...SCALA Installation and operating instructions GRUNDFOS INSTRUCTIONS http waterheatertimer org Water heater recirculation system html...

Страница 2: ...9 8 Setting the product 10 8 1 Setting the outlet pressure 10 8 2 Locking and unlocking the operating panel 10 8 3 Expert settings SCALA2 10 8 4 Resetting to factory settings 11 9 Servicing the produ...

Страница 3: ...1 25 bar 18 psi In case of suction lift of more than six metres the pipe resistance on the outlet side must be at least two metres water column or 3 psi at any given flow in order to obtain optimum op...

Страница 4: ...f the flexible hose Fig 4 How to reduce noise in the installation 3 3 5 Installation examples Fittings hoses and valves are not supplied with the pump We recommend to follow the installation examples...

Страница 5: ...ction lift is 8 m 26 ft H2 Inlet pipe must be submersed at least 0 5 m 1 64 ft TM06 4348 4117 Pos Description 1 Highest tapping point 2 Pipe hangers 3 Isolating valve 4 Flexible hoses 5 Drain to sewer...

Страница 6: ...ertain that the pump is connected only to a properly grounded grounding type receptacle protective earthing If national legislation requires a Residual Current Device RCD a Ground Fault Circuit Interr...

Страница 7: ...ent of an internal leakage occurs the liquid will be drained through the bottom of the pump Install the pump in such a way that no undesirable collateral damage can arise 5 Handling and storing the pr...

Страница 8: ...temperature 13 Minimum and maximum rated power 14 Model 15 Voltage and frequency 16 Approvals 17 Minimum and maximum rated current DK 8850 Bjerringbro Denmark SCALA2 3 45 AKCHDE Model A 200 240V 50 60...

Страница 9: ...e cause has disappeared or been remedied See section 8 3 3 Auto reset For further information about system status see section 12 Fault finding the product TM06 3301 5114 SCALA2 Function On off Increas...

Страница 10: ...tpoint The pump will lower the setpoint to either 4 5 3 5 or 2 5 bar 65 51 or 36 psi The self learned setpoint is indicated on the operating panel by one flashing green light After every 24 hours the...

Страница 11: ...bottom and can easily be removed and cleaned with a stiff brush See fig 19 Clean the insect filter once a year or as needed Fig 19 Insect filter 9 1 2 Inlet and outlet valves The pump is maintenance f...

Страница 12: ...uct 4 The pump will remember the controller settings even if it is turned off 10 1 Deblocking the pump The end cover incorporates a plug which can be removed by means of a suitable tool This makes it...

Страница 13: ...reset function in the service menu Grundfos Eye Indication Description No lights are on The power is off The pump is not running Two opposite green indicator lights running in the direction of rotatio...

Страница 14: ...completely or partly open position Clean repair or replace the non return valve See section 9 Servicing the product 2 The pump is running a Leakage from the pipe system or the non return valve is not...

Страница 15: ...ump but it runs only for a few seconds Yes a Dry running or water shortage Check the water source and prime the pump Yes b The inlet pipe is blocked by impurities Clean the inlet pipe Yes c The foot o...

Страница 16: ...ontact the nearest Grundfos company or service workshop See also end of life information on www grundfos com product recycling Temperature C F Maximum ambient temperature 1 x 208 230 V 60 Hz 45 113 1...

Страница 17: ...8 5005 Korea GRUNDFOS Pumps Korea Ltd 6th Floor Aju Building 679 5 Yeoksam dong Kangnam ku 135 916 Seoul Korea Phone 82 2 5317 600 Telefax 82 2 5633 725 Latvia SIA GRUNDFOS Pumps Latvia Deglava biznes...

Страница 18: ...8564 The name Grundfos the Grundfos logo and be think innovate are registered trademarks owned by Grundfos Holding A S or Grundfos A S Denmark All rights reserved worldwide Copyright Grundfos Holding...

Отзывы: