4.2 Mechanical installation
Install the unit on the discharge side of the pump.
The unit has a built-in non-return valve.
The unit can be connected directly to the pump
discharge port or between the pump and the first
tapping point.
4.3 Location
The unit must be positioned so that it is protected
from rain and direct sunlight.
The unit can be installed in systems with or without a
pressure tank.
Fig. 2
PM Rain and JP pump
Fig. 3
PM Rain and SB pump
Fig. 4
Installation example
Pos. A in fig. 4:
We recommend you to install the unit so that the
height between the unit and the highest tapping point
does not exceed the values in the table below.
* Default setting.
Note
Use a suitable thread seal tape on the
male and female threads of the
PM Rain.
Note
A mounting bracket for wall mounting
can be ordered separately.
TM
05 15
17 291
1
Note
We recommend PM Rain and JP pump
for positively fed systems only, for
example above-ground collecting
tanks.
TM
05
15
18
31
1
1
Note
We recommend PM Rain and SB pump
for suction applications, for example
underground collecting tanks.
Mains water
Mains water
TM
05 15
34 321
1
Start pressure set
Maximum height
[bar]
[kPa]
[m]
2.5*
250
21
3.0
300
26
3.5
350
31
4.0
400
36
4.5
450
41
5.0
500
46
5.5
550
51
6.0
600
56