![Grundfos PLV Series Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/grundfos/plv-series/plv-series_installation-and-operating-instructions-manual_2271143011.webp)
English (GB)
11
7. Fault finding
8. Spare parts and accessories
8.1 Adapter for installation directly on the pump (up to 60 l/h)
* Stainless steel 1.4571, according to EN 10027-2
8.2 Spare parts for pressure loading valves up to 60 l/h
8.3 Set of counter flanges for pressure loading valves DN 32 and DN 65
* Stainless steel 1.4571, according to EN 10027-2
Fault
Possible cause
Possible remedy
The pressure loading valve does not
produce any counterpressure.
Defective diaphragm.
Replace the diaphragm.
Dirt in the pressure loading valve.
Rinse the pressure loading valve.
Opening pressure set too low.
Set the pressure loading valve to a higher
opening pressure.
Connections
Housing
Product number
Description
G 5/8 - G 5/8
PVC
95730437
PVC nut G 5/8 - nut G 5/8
PP
95730438
PP nut G 5/8 - nut G 5/8
PVDF
95730439
PVDF nut G 5/8 - nut G 5/8
G 5/8 - 1/4"
SS*
96693273
SS nut G 5/8 - 1/4"
Description
Suitable for housing materials
Product number
Diaphragm
all
91834367
Pressure spring
all
91834370
Adjusting screw
all
96679604
Kit, gaskets 2 pcs - G 5/8 V/E
PVC, PP, PVDF
95731456
Kit, gaskets 2 pcs - G 5/8 T
PVC, PP, PVDF
95731457
Size
Material
Product number
Description
DN 32
SS*
91835727
Includes lapped flange, headed bush, screws, washers, nuts
DN 32
PVC
91835728
DN 32
PVDF
96727588
DN 65
PVC
96727602
DN 65
PP
96727603
DN 32
PP
96727589
Includes welding neck flange, flat gasket, screws, washers, nuts
DN 65
SS*
96727604
Includes welding neck flange, screws, washers, nuts
Содержание PLV Series
Страница 1: ...GRUNDFOS INSTRUCTIONS Pressure loading valves Installation and operating instructions ...
Страница 13: ...13 ...