8.1.3 Target value external
System capacity control and processing the input and output
signals via the bus system.
• Select the bus system used in the "Basic Settings/Bus
Options" menu, see section
• Activate the bus control in the "Operation mode" (page 2).
Scroll with the arrow [RIGHT] key in the "Operation mode"
menu. Select the "Bus control" mode using the [F2] key.
• Use the [Enter] and [Escape] key to return to the main menu.
Display page 1
• Switch to page 3 using the arrow [RIGHT] key.
• Use the [F1] key to switch to the "local/remote" menu.
• Select control mode using the [F1] or [F2] key.
• Use the [Enter] or [Escape] key to return to the main menu.
Local control
Operation and control of the installation on-site, by manual entry
of the installation capacity in % terms in "Manual" mode.
Remote control
Control of the installation via the bus system in "Automatic"
mode.
8.2 Manual operation
• In the main menu, switch to the "Manual > start?" menu using
the [F1] key.
The input field "x.x" shows the dosing capacity setting in %.
Setting the dosing capacity
• Select the input field "x.x" using the [F1] key.
• Use the [UP] and [DOWN] keys to change the numerical
value, and the arrow [LEFT] and [RIGHT] keys to change the
input field. Dosing capacity range from 0 to 100 %.
• Confirm entry using [Enter] key.
• Activate or deactivate the system using the [Enter] key.
The display changes from "start?" to "active", or from "active"
to "start?". The display shows the most important information
about the operation of the system. Further information,
such as levels, dosing pumps and bypass water, can be
obtained by scrolling with the arrow keys to the pages 2 and 3.
8.2.1 Manual mode for batch
Target value external
activated
Main menu
1 Automatic
2 Manual operation
3 Logbook
>
Main menu
<
1 local/remote
Note
The "local/remote" menu is only displayed, if a bus
system was selected in the "Basic settings/Bus
options" menu.
Local/remote
1 local control
2 remote control
local control/remote control
activated
Auto: x.x %
Start?
Dosing:
xxx %
Bypass:
xxx l/h
ClO
2
:
x.x g/h >
Note
Irrespective of the selected mode, the system can
only be activated in "Manual" mode if the installation
capacity has been set manually in %.
Note
Given the pulse pause control of the dosing pumps
for HCl and NaClO
2
dosing capacity ranges under
2.5 % are not possible.
A dosing capacity set on the display less than 2.5 %
leads to dosing of 0 %.
A dosing capacity set on the display more than 95 %
leads to a dosing capacity of 100 %.
Manual: x.x %
Start?
Dosing:
xxx %
Bypass:
xxx l/h
ClO
2
:
x.x g/h >
Note
The display pages 2 and 3 (levels, dosing pump,
bypass) are analog to automatic operation,
see section
Note
The operation and functions are the same as in
automatic mode, except the solution container is not
continually filled between the contacts MIN and MAX
as in automatic operation, but rather is only filled
once up to the MAX contact. Then the system shuts
down.
Note
In manual mode, the system does not automatically
switch on when the MIN contact in the solution
container is reached.
Содержание Oxiperm OCD-164
Страница 2: ...2...
Страница 247: ...Fran ais FR 247 4 crou filtre PVC gris...
Страница 420: ...RU 420 1 10 1 10 1 20 TrinkwV 2001 0 4 1 10 2 1 10 3 EN 12671 D 15 7 5 DIN EN 938 9 0 DIN EN 939 HCl NaClO2...
Страница 422: ...RU 422 10 10...
Страница 430: ...RU 430 5 4 2 0 1 1 8 5 4 3 42 9 5 4 4 ClO2 ClO2 ClO2 2 3 3 TM04 8200 4510 11 1D O2 O TM04 8201 4510 1D O2 O...
Страница 431: ...RU 431 10 5 5 2 1 5 5 6 5 6 1 5 6 1 TM04 8202 4510 50 60 6 20 11 1D O2 O...
Страница 432: ...RU 432 5 6 2 1 2 3 20 20 4 11 4 5 4 4 5 4 6 5 6 5 6 TM04 8203 4510 1 20 2 3 4 5 6...
Страница 455: ...RU 455 34 HCl 35 HCl 36 NaClO2 37 NaClO2 38 H2O 39 H2O 40 ClO2 41 HCl 42 NaClO2 43 H2O 44 45 46 47...
Страница 526: ...526...