8. Operation of the system
Independent from the operation mode, the menu structure
remains the same, the only difference is in the display of the
prevailing signals, i.e. current input in mA, contact input in 1/s and
manual mode in %.
Main menu
8.1 Automatic operation
8.1.1 Current input/contact input
• In the main menu, switch to the "Automatic > start" menu using
the [F1] key.
Depending on the mode setting, the x.x/y.y field indicates the
prevailing current signal in mA or the prevailing contacts
(contact water meter) in 1/s.
• Activate or deactivate the system using the [Enter] key.
The display changes from "start?" to "active" or from "active"
to "start?". The display shows the most important information
about the operation of the system. Further information, such
as levels, dosing pumps and bypass water, can be obtained by
scrolling with the arrow keys to the pages 2 and 3.
Display page 2
Level
• Use the [F1] key to switch to the "Level" menu.
• Use the [Escape] key to return.
On page 2, scroll on with the arrow keys:
Display page 3
Dosing pump
• Use the [F1] key to switch to the "Dosing pumps" menu.
The Hall sensor signals and the signals from the flow
controllers can be checked in this menu.
The default value changes as the installation runtime
progresses, whereby the following evaluation is decisive.
H = X: Hall sensor signals
D = X: flow controller signals.
• Use the [Escape] key to return.
Bypass water
• Use the [F2] key to switch to the "Bypass water" menu.
The target and actual value for the bypass water can be
checked in this menu. The limits can also be changed in this
menu.
Changing the limit
• Use the [F1] key to switch to the input field -XX or +600 %
• Enter the value by pressing the [UP] or [DOWN] keys (to
change the number), and the [LEFT] and [RIGHT] arrow keys
(to change the input position).
• Switching from -XX to +600 or from +600 to -XX is carried out
using the [F1] key.
• Press the [Enter] key to confirm the entry.
• Use the [Escape] key to return.
Note
Before the system is started, the system size and
operation mode must be selected.
Main menu
1 Automatic
2 Manual operation
3 Logbook
>
Note
In "Manual control" mode, automatic operation is
impossible.
Auto: x.x/y.y
Start?
Dosing
xxx %
Bypass
xxx l/h
ClO
2
x.x g/h >
Auto: start?
<
1 Level
3 Logbook
>
Level
HCl:
MIN - MAX
NaClO
2
:
MIN - MAX
Auto:
Start? <
1 Dosing pumps
2 Bypass
>
NaClO
2
H = X
D = Y
HCl
H = X
D = Y
Note
The values displayed here are not identical to the
dosing stroke details from the individual dosing
pumps, e.g. 120 strokes/min, because the calculation
does not relate to 1 minute.
D = H
Each of the Hall sensor signals from the dosing
pump is fed back by the flow controller.
D > H
More flow controller signals are fed back, i.e. if the
deviation is too large, this reduces the precision of
the flow monitor, although the system keeps running
(there is no error message).
D < H
Too few dosing controller signals are fed back, the
system goes into malfunction mode. The dosing
controller settings have to be checked.
Note
The installation is correctly set at D = H whereby a
few extra dosing controller signals (D > H) have no
bearing on the precision of the system.
Bypass water
<off>
setpt.:
xxx l/h
actual:
xxx l/h
1 limit:
-XX/+600 %
Note
If a new system size is set, the preset limits for the
new system are loaded.
Содержание Oxiperm OCD-164
Страница 2: ...2...
Страница 247: ...Fran ais FR 247 4 crou filtre PVC gris...
Страница 420: ...RU 420 1 10 1 10 1 20 TrinkwV 2001 0 4 1 10 2 1 10 3 EN 12671 D 15 7 5 DIN EN 938 9 0 DIN EN 939 HCl NaClO2...
Страница 422: ...RU 422 10 10...
Страница 430: ...RU 430 5 4 2 0 1 1 8 5 4 3 42 9 5 4 4 ClO2 ClO2 ClO2 2 3 3 TM04 8200 4510 11 1D O2 O TM04 8201 4510 1D O2 O...
Страница 431: ...RU 431 10 5 5 2 1 5 5 6 5 6 1 5 6 1 TM04 8202 4510 50 60 6 20 11 1D O2 O...
Страница 432: ...RU 432 5 6 2 1 2 3 20 20 4 11 4 5 4 4 5 4 6 5 6 5 6 TM04 8203 4510 1 20 2 3 4 5 6...
Страница 455: ...RU 455 34 HCl 35 HCl 36 NaClO2 37 NaClO2 38 H2O 39 H2O 40 ClO2 41 HCl 42 NaClO2 43 H2O 44 45 46 47...
Страница 526: ...526...