background image

En
gl

is

h (
G

B)

4

3. Product introduction

The MS1 and MS1 Ex float switches are ON/OFF 
switches. Gold-plated contacts ensure operation at 
extra low voltage. The MS 1 float switch is specially 
designed for use in wastewater treatment plants and 
in pump stations which handle liquids polluted with 
solids. Thanks to its good chemical properties, it is 
resistant to a wide range of liquids. Resistance list: 
raw sewage, fecal discharges, slurry, household 
sewage, discharge water from washing machines, 
baths and showers, detergents, emulsions 
containing petrol, diesel oils, fats, oil, acids etc. rain 
water, groundwater, chlorinated water.
The MS1 Ex float switch can be used in a certified, 
intrinsically safe-circuit electrical system for the 
control and regulation of liquid levels in Zones 0, 1 
and 2 Ex- areas. It can also be used in the presence 
of gas groups IIA, IIB and IIC, where there is a risk of 
explosion when these are in contact with flammable 
materials and exposed to temperatures in the range 
T1 - T6.

4. Servicing the product

If the float switch is installed and assembled 
correctly, it should work practically maintenance-free 
for many years. Depending on the level of 
contamination in the medium, the system only needs 
to be checked from time to time and the float switch 
cleaned, if necessary.

5. Technical data

6. Disposing of the product

This product or parts of it must be disposed of in an 
environmentally sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest 

Grundfos company or service workshop.

The crossed-out wheelie bin symbol on 
a product means that it must be 
disposed of separately from household 
waste. When a product marked with this 
symbol reaches its end of life, take it to a 
collection point designated by the local 

waste disposal authorities. The separate collection 
and recycling of such products will help protect the 
environment and human health.
See also end-of-life information at 
www.grundfos.com/product-recycling.

DANGER

Electric shock

Death or serious personal injury
- Before starting any work on the product, 

make sure that the power supply has 
been switched off and that it cannot be 
accidentally switched on.

WARNING

Toxic material

Death or serious personal injury
- Before entering the pit, make sure that 

the pit is ventilated according to local 
regulations. If not, do not enter the pit.

CAUTION

Biological hazard

Minor or moderate personal injury
- Use gloves and other suitable personal 

protection equipment in accordance 
with local regulations. Observe local 
regulations on exposure to wastewater.

MS1

MS1 Ex 

Housing colour

Orange

Black

Cable colour

Orange

Blue

Specific density (in 
liquid)

0.95 - 1.05

0.95 - 1.05

Maximum 
temperature

80 °C

80 °C

Breaking capacity

1-100 mA / 4 V 
- 5 A / 250 V

1-100 mA / 4-40 V

Contact

SPDT

SPDT

Switching angle

10 °

10 °

Protection system

IP68 / 7 bar

IP68 / 2 bar

Housing material

Polypropylene

PRE-ELEC 
Polypropylene

Cable material

TPR/PVC

TPR/PVC

Height

180 mm

180 mm

Diameter

100 mm

100 mm

Cable cross section 3 x 0.75 mm

2

4G0.75 mm

2

Ex classification

-

II 1G Ex ia IIC T6

Certification

-

SEV 18 ATEX 0143
IECEx SEV 18.0015

Ratings

-

Ui = 40 V
Ii = 100 mA
Ci = 0 nF + 0.11 nF/m
(connection cable)
Li = 0 

μ

H + 0.35 

μ

H/m 

(connection cable)

Содержание MS1

Страница 1: ...MS1 and MS1 Ex Float switch Installation and operating instructions GRUNDFOS INSTRUCTIONS ...

Страница 2: ... Notes 3 2 Installing the product 3 2 1 Mechanical installation 3 2 2 Electrical connection 3 3 Product introduction 4 4 Servicing the product 4 5 Technical data 4 6 Disposing of the product 4 Read this document and the quick guide before installing the product Installation and operation must comply with local regulations and accepted codes of good practice This appliance must only be installed by...

Страница 3: ...tion must be taken A red or grey circle with a diagonal bar possibly with a black graphical symbol indicates that an action must not be taken or must be stopped If these instructions are not observed it may result in malfunction or damage to the equipment Tips and advice that make the work easier To avoid the risk of the buildup of an electrostatic charge the casing of the float switch must be con...

Страница 4: ...arest Grundfos company or service workshop The crossed out wheelie bin symbol on a product means that it must be disposed of separately from household waste When a product marked with this symbol reaches its end of life take it to a collection point designated by the local waste disposal authorities The separate collection and recycling of such products will help protect the environment and human ...

Страница 5: ...Appendix 5 Appendix 1 Fig 1 MS1 or MS1 Ex float switch Fig 2 To empty or alarm at high liquid level Fig 3 To fill or alarm at low liquid level TM07 2281 3018 TM07 2279 3018 TM07 2280 3018 2 1 3 3 2 1 ...

Страница 6: ...agállamainak jogi irányelveit összehangoló tanács alábbi előírásainak IT Dichiarazione di conformità UE Grundfos dichiara sotto la sua esclusiva responsabilità che il prodotto MS1 MS1 Ex al quale si riferisce questa dichiarazione è conforme alle seguenti direttive del Consiglio riguardanti il riavvicinamento delle legislazioni degli Stati membri UE LT ES atitikties deklaracija Mes Grundfos su visa...

Страница 7: ...roduct Testing AG Luppmenstrasse 3 8320 Fehraltorf Switzerland CH Applied harmonized EC Norms Directive 2011 65 EU RoHS Directive 2014 34 EU ATEX Standards used EN 60079 0 12 A11 13 EN 60079 11 12 EN 60079 26 15 Application in intrinsically safe electrical circuits in EX Zone 0 1 and 2 This EU declaration of conformity is only valid when published as part of the Grundfos safety instructions public...

Страница 8: ...ro Tlf 45 87 50 50 50 Telefax 45 87 50 51 51 E mail info_GDK grundfos com www grundfos com DK Estonia GRUNDFOS Pumps Eesti OÜ Peterburi tee 92G 11415 Tallinn Tel 372 606 1690 Fax 372 606 1691 Finland OY GRUNDFOS Pumput AB Trukkikuja 1 FI 01360 Vantaa Phone 358 0 207 889 500 France Pompes GRUNDFOS Distribution S A Parc d Activités de Chesnes 57 rue de Malacombe F 38290 St Quentin Fallavier Lyon Tél...

Страница 9: ...0 1426 sk grundfos com Slovenia GRUNDFOS LJUBLJANA d o o Leskoškova 9e 1122 Ljubljana Phone 386 0 1 568 06 10 Telefax 386 0 1 568 06 19 E mail tehnika si grundfos com South Africa GRUNDFOS PTY LTD Corner Mountjoy and George Allen Roads Wilbart Ext 2 Bedfordview 2008 Phone 27 11 579 4800 Fax 27 11 455 6066 E mail lsmart grundfos com Spain Bombas GRUNDFOS España S A Camino de la Fuentecilla s n E 28...

Страница 10: ...9610 Trademarks displayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2018 Grundfos Holding A S all rights reserved ...

Отзывы: