3.4 Mechanical installation of KPG
Observe the maximum cable bend radius, see
.
Prior to installation, check the oil level in the oil
chamber. See section
Take particular care when installing the pumps, as
the procedure is not similar to that of other
submersible pumps.
3.4.1 Guide for pit construction
DANGER
Electric shock
Death or serious personal injury
- Before beginning the installation, switch
off the power supply and lock the main
switch in position 0/Off.
- Before working on the pump, switch off
any external voltage connected to the
pump.
Observe all safety regulations at the
installation site, for instance the use of
blowers for fresh-air supply to the pit.
TM
07
47
1
3
23
19
0
M
2
3
3.5
KUM-A
1
G.P.I
0.5
1.5
2.5
0
M
2
3
3.5
KUM-A
1
G.P.I
0.5
1.5
2.5
B1
D
C
A1
A1
0
M
2
3
3.5
KUM-A
1
G.P.I
0.5
1.5
2.5
B2
A2
D
Model
Outlet diameter
1 gate and 1 pump
1 gate and 2 pumps
A1
[mm]
B1
[mm]
C
[mm]
A2
[mm]
B2
[mm]
KPG.500
DN 500
1250
1950
900
1900
900
KPG.600
DN 600
1400
2100
900
2200
1000
KPG.700
DN 700
1500
2200
900
2400
1100
KPG.800
DN 800
1800
2500
900
2800
1300
KPG.900
DN 900
1900
2600
900
3000
1400
KPG.1000
DN 1000
2100
2800
900
3300
1600
KPG.1200
DN 1200
2600
3300
900
4000
2000
KPG.1400
DN 1400
3000
3700
900
4800
2400