6. Fault finding

DANGER

Electric shock

Death or serious personal injury
- Switch off the power supply before 

starting any work on the product. Make 
sure that the power supply cannot be 
accidentally switched on.

Fault

Cause

Remedy

1.

The pump does 
not start.

a)

Supply failure.

Cut in the circuit breaker or replace the fuses. 
If the new fuses also blow, check the electric 
installation.

b)

The pump is blocked by 
impurities.

Clean the pump. Check or replace the strainer 
in the inlet pipe.

c)

The motor is defective.

Replace the pump. 

2.

The pump runs, 
but gives no or just 
a little water.

a)

The pump is not filled with 
water.

Prime the pump. See section 

3. Starting up the 

product

.

b)

The inlet pipe is blocked by 
impurities.

Clean the inlet pipe. Check or replace the 
strainer in the inlet pipe.

c)

The pump is blocked by 
impurities.

Clean the pump. Check or replace the strainer 
in the inlet pipe.

d)

The suction lift is too high.
JPA, JPC: Maximum 7 m.
JPD: Maximum 27 m.

Change the position of the pump.

e)

The inlet pipe is too long.

Change the position of the pump.

f)

The diameter of the inlet pipe 
is too small.

Replace the inlet pipe.

g)

The inlet pipe is not immersed 
deeply enough.

Make sure that the inlet pipe is immersed 
sufficiently.

h)

The inlet pipe is leaking.

Repair or replace the pipe.

3.

The pump runs, 
but gives no water 
or delivers a 
reduced quantity 
of water at high 
pressure.

a)

The outlet pipe is blocked.

Clean the pipe or open the isolating valves, if 
fitted.
Check that no additional work is being carried 
out in the system.

4.

The motor cuts out 
during operation.

a)

The thermal switch in the 
motor has tripped due to 
overheating.

The thermal switch will cut in automatically 
when the motor has cooled sufficiently.
If the problem persists, check these two 
possible causes:
• The impeller is stuck.

Clean the pump.

• The motor is defective.

Replace the pump. 

Содержание JPA 12-41

Страница 1: ...JPA JPC JPD PT Pumps and boosters Installation and operating instructions GRUNDFOS INSTRUCTIONS...

Страница 2: ...ration must comply with local regulations and accepted codes of good practice This appliance can be used by children aged from 8 years and above and by persons with reduced physical sensory or mental...

Страница 3: ...le to the liquid to be pumped 2 2 1 Frost protection If the pump is not used during periods of frost it must be drained to avoid damage Remove the drain plug to drain the pump See fig 3 Fig 3 Draining...

Страница 4: ...ong horizontal stretches we recommend that you use an inlet pipe with a diameter larger than the inlet opening of the pump Fig 5 Inlet pipe sloping upwards 2 3 3 JPD deep well installation A JPD must...

Страница 5: ...onnected to the protective earth of the pump The plug must therefore have the same PE connection system as that of the socket outlet If not use a suitable adapter We recommend that you fit the permane...

Страница 6: ...r serious personal injury Do not use the pump for flammable liquids such as diesel oil petrol or similar liquids CAUTION Impurities in water Minor or moderate personal injury Flush the system with cle...

Страница 7: ...e number of starts and stops an external tank can be installed JPA PT and JPC PT are boosters consisting of a pump a pressure switch a pressure gauge and a diaphragm tank The pressure switch automatic...

Страница 8: ...1 17 16 15 14 13 2 3 4 5 6 7 8 12 11 10 9 3 1 TM06 7713 4016 Pos Description 1 Pump type 2 Product number 3 Full load current 4 Factory and production date 5 Motor input power 6 Pump output power 7 M...

Страница 9: ...ts are available for the JPA JPC JPD pumps and boosters The service kits consist of the following replaceable parts shaft seal hydraulic parts capacitor DANGER Electric shock Death or serious personal...

Страница 10: ...ies Clean the pump Check or replace the strainer in the inlet pipe d The suction lift is too high JPA JPC Maximum 7 m JPD Maximum 27 m Change the position of the pump e The inlet pipe is too long Chan...

Страница 11: ...48 5 JPD 4 47 PT 4 JPD 4 54 PT 4 JPD 5 61 PT 5 JPD 8 62 PT 8 Pump type m JPA 3 42 JPA 3 42 PT H 42 JPA 4 47 JPA 4 47 PT H JPA 4 47 PT V 47 JPA 4 54 JPA 4 54 PT H JPA 4 54 PT V 54 JPA 5 61 JPA 5 61 PT...

Страница 12: ...ate waste collection service 2 If this is not possible contact the nearest Grundfos company or service workshop See also end of life information on www grundfos com The crossed out wheelie bin symbol...

Страница 13: ...13...

Страница 14: ...1 51 E mail info_GDK grundfos com www grundfos com DK Estonia GRUNDFOS Pumps Eesti O Peterburi tee 92G 11415 Tallinn Tel 372 606 1690 Fax 372 606 1691 Finland OY GRUNDFOS Pumput AB Trukkikuja 1 FI 013...

Страница 15: ...ona 421 2 5020 1426 sk grundfos com Slovenia GRUNDFOS LJUBLJANA d o o Lesko kova 9e 1122 Ljubljana Phone 386 0 1 568 06 10 Telefax 386 0 1 568 06 19 E mail tehnika si grundfos com South Africa Grundfo...

Страница 16: ...450 Trademarks displayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2019 G...

Отзывы: