English (GB)
12
11.1.2 Start or stop the system
Start each pump by pressing
or by continuously pressing
until the desired setpoint is indicated.
Stop the system by pressing
on each pump. When the pump
is stopped, the "Stop" text next to the button will illuminate. Each
pump can also be stopped by continuously pressing
until
none of the light fields are on.
If a pump has been stopped by pressing
, it can only be given
free to operation by pressing
again.
If a pump has been stopped by pressing
, it can only be
restarted by pressing
.
The pump can also be stopped with Grundfos GO Remote or via
a digital input set to "External stop". See section
.
11.1.3 Resetting of fault indications
A fault indication can be reset in one of the following ways:
• Via the digital input if it has been set to "Alarm resetting".
• Briefly press
or
on one of the pumps. This will not
change the setpoint.
A fault indication cannot be reset by pressing
or
if the
buttons have been locked.
• Switch off the power supply until the indicator lights are off.
• Switch the external start/stop input off and then on again.
• With Grundfos GO Remote.
12. Grundfos GO Remote
The system is designed for wireless radio or infrared
communication with Grundfos GO Remote.
Grundfos GO Remote enables setting of functions and gives
access to status overviews, technical product information and
actual operating parameters.
Grundfos GO Remote offers three different mobile interfaces
(MI). See fig.
Fig. 18
Grundfos GO Remote communicating with the pump
via radio or infrared light
12.1 Communication
When Grundfos GO Remote communicates with the pump, the
indicator light in the middle of Grundfos Eye will flash green. See
section
Communication must be established using one of these
communication types:
• radio communication
• infrared communication.
12.1.1 Radio communication
Radio communication can take place at distances up to 30
metres. Enable communication by pressing
or
on the
pump control panel.
12.1.2 Infrared communication
When communicating via infrared light, point Grundfos GO
Remote at the pump control panel.
TM
05
53
83
43
12
Pos.
Description
1
Grundfos MI 201:
Consists of an Apple iPod Touch 4G and a Grundfos
cover.
2
Grundfos MI 202:
Add-on module which can be used in conjunction
with an Apple iPhone or iPod with 30-pin connector
and iOS 5.0 or later, e.g. fourth generation iPhone or
iPod.
Grundfos MI 204:
Add-on module which can be used in conjunction
with an Apple iPhone or iPod with Lightning
connector, e.g. fifth generation iPhone or iPod. (The
MI 204 is also available together with an Apple iPod
touch and a cover.)
3
Grundfos MI 301:
Separate module enabling radio or infrared
communication. The module can be used in
conjunction with an Android or iOS-based
Smartphone with Bluetooth connection.
+
1
2
3
+
+