Quick Guide 

 
This is a simplified guide to the installation and commissioning of the Grundfos Home Booster. Please refer to the individual sections 
in this document for precise details for each step. 
 
There is no need to open the pressure manager and change the DIP switch settings, as they are factory set. 
 

INSTALLATION 

Install the Home Booster on to a flat and level solid foundation. 
Conect the mains water supply. 
Connect the overflow pipe work. 
Connect the discharge pipe work. 
Connect the electrical supply cable. 
 

COMMISSIONING 

Spend some time venting the pump carefully, if the pump contains air it will not gerate pressure. 
To vent the pump open the discharge valve and a outlet fitting (tap) at low level. 
Vent the pump for 30 to 60 seconds, using the vent screw on the pump. 
 

TESTING 

Switch on the electrical supply. 
The pump will start, and the pressure will begin to increase as shown by the indicator lights. 
Once the pressure has built up, close the isolating valve within the Home Booster. The pump will run-on for several tens of seconds 
and then stop. 
Open the isolating valve within the Homer Booster, the pressure will begin to fall if the outlet fitting has been left open. The pump will 
then start again and the pressure increase. The pump will continue to run while there is a flow demand.  
Close the outlet fitting, the pump will stop after a short time. If the pump does not stop, then there is a flow demand which is causing 
the pump to continue operating.  
If the pump continues to run even though the outlet fitting is closed, then close the isolating valve within the Homer Booster, the 
pump should stop again.  
Investigate the cause of the flow demand, for example filling toilet cistens etc. 
 

Содержание Home Booster 3.0

Страница 1: ...Page 1 Home Booster 3 0 4 5 bar Installation Operating Instructions Residential and Light Commercial Package cold water pressure booster set...

Страница 2: ...ocal regulations and accepted codes of practice WARRANTY 1 The Grundfos warranty covers all defects within the Home Booster originating from faulty workmanship and or materials for a period of two yea...

Страница 3: ...ng the vent screw on the pump TESTING Switch on the electrical supply The pump will start and the pressure will begin to increase as shown by the indicator lights Once the pressure has built up close...

Страница 4: ...will cause disturbance and considerable water damage could result if a leak occurs Please provide drainage facilities for the unit in case of leakage or loss of water during commissioning and service...

Страница 5: ...Home Booster tank first This arrangement can be of benefit where the mains water supply is poor at refilling the storage tank Ensure that the support base is able to support the combined weight of th...

Страница 6: ...res on the following pages please ensure that the following connections and checks have been carried out on the booster set 1 The discharge connection is connected to the system pipework 2 The electri...

Страница 7: ...should be drained to avoid damage Remove all drain and vent plugs and allow the pump to drain Do not replace the plugs until the booster set is to be used again The pump must be vented primed before...

Страница 8: ...ure but does not stop with no demand a b Pressure setting to high Flow demand or leak a b Check switch settings in PM2 controller Close outlet isolating valve the pump should stop If the pump stops th...

Отзывы: