English (GB)
29
16.9 Effect of ambient temperature and altitude on
engine output
If the ambient temperature exceeds 25 °C (see fig. 30) or if the
engine is installed more than 90 m above sea level (see fig. 31),
the engine must not be fully loaded. In such cases, it may be
necessary to use a larger engine.
Fig. 30
Relation between engine output P2 and ambient
temperature
Fig. 31
Relation between engine output P2 and altitude
17. Disposal
This product or parts of it must be disposed of in an
environmentally sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest Grundfos company
or service workshop.
Subject to alterations.
Note
See installation and operating instructions for
the engine for more detailed information.
TM
03 471
8 260
6
T
M
03
47
17
26
06
20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95
50
60
70
80
90
100
[%]
P2
80
100
120
140
160
180 T [°F]
T [°C]
0
500 1000 1500 2000 2500 3000 3500 4000 4500 5000
[m]
50
60
70
80
90
100
[%]
P2
0
2000
4000
6000
8000 10000 12000 14000
[ft]