5.12 Analog
The pump is dosing according to an external analog
signal. The dosed quantity is proportional to the input
value in mA.
4-20 (default): 4 mA =
0 %.
20 mA = 100 %.
20-4:
4 mA = 100 %.
20 mA =
0 %.
0-20:
0 mA =
0 %.
20 mA = 100 %.
20-0:
0 mA = 100 %.
20 mA =
0 %.
.
The capacity limitation will influence the capacity.
100 % corresponds to the maximum capacity of the
pump or the set maximum capacity, see section
The analog input requires a signal which is isolated
from frame. Min. resistance to frame: 50 k
Ω
Fig. 9
Fig. 10
If 4-20 mA or 20-4 mA is selected and the signal falls
below 2 mA, the pump will indicate a fault. This
situation occurs if the connection is interrupted, for
instance if the wire is damaged.
Change the analog mode as illustrated in fig.
Fig. 11