Related information
5.14 Batch
The pump is dosing the set quantity in batches at the
maximum capacity or the set maximum capacity, see
section Capacity limitation.
The quantity is dosed every time the pump receives
an external pulse.
If the pump receives new pulses before the previous
batch is performed, these pulses will be ignored.
1
2
2
TM018947
Pos. Description
1
Quantity per batch
2
Pulse
The setting range is the same as for Timer, see
section Timer.
1
TM077983
Pos. Description
1
Set value per batch
Related information
5.13 Timer
5.16 Capacity limitation
5.15 Anti-cavitation
The pump features an anti-cavitation function. When
this function is selected, the pump extends its suction
stroke, resulting in optimized priming.
The anti-cavitation function is used:
•
when pumping liquids of high viscosity
•
in the case of a long suction tube
•
in the case of a high suction lift.
Depending on the circumstances, the motor speed
during the suction stroke can be reduced by 75 %, 50
% or 25 % compared to the normal motor speed
during the suction stroke.
The maximum pump capacity is reduced when the
anti-cavitation function is selected. See section
Mechanical data.
24
English (GB)
Содержание DME 150 AP
Страница 2: ......