Condition
Green LED
Red LED
Display
Alarm output
Empty tank
Off
On
EMPTY
2
1
3
NC
NO
C
Analog signal < 2 mA
Off
On
NO mA
2
1
3
NC
NO
C
The pump is running,
but the dosed
is too small according
to the signal from the
dosing monitor
On
On
NO FLOW
2
1
3
NC
NO
C
Overheating
Off
On
MAX. TEMP.
2
1
3
NC
NO
C
Internal communication
fault
Off
On
INT. COM.
2
1
3
NC
NO
C
Internal Hall fault
Off
On
HALL
2
1
3
NC
NO
C
Diaphragm leakage
Off
On
LEAKAGE
2
1
3
NC
NO
C
Maximum pressure
exceeded
Off
On
OVERLOAD
2
1
3
NC
NO
C
More pulses than
capacity
On
On
MAX. FLOW
2
1
3
NC
NO
C
No motor rotation
detected
Off
On
ORIGO
2
1
3
NC
NO
C
1)
Requires connection to level sensors. See section Empty tank (alarm).
2)
Requires activation of the dosing monitoring function and connection to a dosing monitor.
3)
Please contact a Grundfos service centre.
4)
Alarms can be reset when the faults have been corrected.
5)
The pump will make 10 attempts to restart before going into permanent OFF mode.