5. Functions
5.1 Control panel
100%
1
2
3
4
5
6
7
8
9
10
11
12
13
14
TM027068
Pos. Description
1
LCD display.
See section Menu
2
Navigation/settings.
See section Menu
3
Green indicator light.
See section Alarm output and indicator lights
4
Maximum capacity (priming).
See section Priming/venting of pump
5
Red indicator light.
See section Alarm output and indicator lights
6
M12 connection analog/pulse/leakage input.
See sections Pulse, Analog, Diaphragm
leakage sensor
7
Cable for Profibus control.
See section Fieldbus communication
8
Connection alarm relay.
See section Alarm output and indicator lights
9
Power supply
10
M12 connection level control.
See section Level control
Pos. Description
11
M12 connection stop dosing.
See section Start/stop of pump
12
On/off button.
See section Menu
13
Navigation/settings.
See section Menu
14
Menu.
See section Menu
Related information
5.2 Start/stop of pump
5.3 Priming/venting of pump
5.4 Level control
5.5 Diaphragm leakage sensor
5.7 Fieldbus communication
5.8 Menu
5.11 Pulse
5.12 Analog
5.2 Start/stop of pump
The pump can be started/stopped in two different
ways:
•
Locally on the pump control panel.
•
By means of an external on/off switch. See
section Connection overview.
Related information
5.3 Priming/venting of pump
The pump control panel incorporates a
100%
button.
Press this button if the maximum pump capacity is
required over a short period, e.g. during start-up.
When the button is released, the pump automatically
returns to the previous operating mode.
During priming/venting, it is recommended to let the
pump run without a counter pressure or to open the
vent valve.
Note:
When the buttons
100%
and
are pressed
simultaneously, the pump can be set to run for a
specific number of seconds at maximum capacity.
The remaining number of seconds will appear in the
display. The maximum value is 300 seconds.
17
English (GB)