background image

2.

Carefully turn the pump head to the desired position and tighten the union.
Open the isolating valves.

TM075636

5. Startup

WARNING

Hot surface

Death or serious personal injury

At high liquid temperatures, the product may become so hot that
only the operating panel must be touched to avoid burns.

WARNING

Electric shock

Death or serious personal injury

Clean only the product with a dry cloth

13

English (US)

Содержание COMFORT 10-16 Auto

Страница 1: ...COMFORT 10 16 Temp Auto and Digital Timer Installation and operating instructions GRUNDFOS INSTRUCTIONS ...

Страница 2: ... 8 4 4 Mounting the product 9 4 5 Installing the temperature sensor 11 4 6 Changing the pump head position 12 5 Startup 13 5 1 COMFORT Auto variants 14 5 2 COMFORT Temperature control variants 15 5 3 COMFORT Digital Timer variants 16 6 Service and dismantle the product 19 7 Fault finding the product 21 7 1 Defective external temperature sensor only COMFORT Auto 21 7 2 Defective internal temperatur...

Страница 3: ...products from which it was purchased together with proof of purchase and installation date failure date and supporting installation data Unless otherwise provided the distributor or dealer will contact Grundfos or an authorized service station for instructions Any defective product to be returned to Grundfos or a service station must be sent freight prepaid documentation supporting the warranty cl...

Страница 4: ...ply with local regulations and accepted codes of good practice 2 1 Hazard statements The symbols and hazard statements below may appear in Grundfos installation and operating instructions safety instructions and service instructions DANGER Indicates a hazardous situation which if not avoided will result in death or serious personal injury WARNING Indicates a hazardous situation which if not avoide...

Страница 5: ...of products A blue or gray circle with a white graphical symbol indicates that an action must be taken A red or gray circle with a diagonal bar possibly with a black graphical symbol indicates that an action must not be taken or must be stopped If these instructions are not observed it may result in malfunction or damage to the equipment Tips and advice that make the work easier 5 English US ...

Страница 6: ...reduced Example 50 glycol at 68 F 20 C means a viscosity of approximately 10 mm2 s reducing pump performance by approximately 15 When selecting a pump the viscosity of the pumped liquid must be taken into account 3 Receiving the product 3 1 Inspecting the product CAUTION Crushing of feet Minor or moderate personal injury Wear safety shoes when handling the product Make sure that the delivered prod...

Страница 7: ...cian in accordance with local regulations WARNING Pressurised system Death or serious personal injury Before installation of the pump drain the system or close the isolating valves on both sides of the pump The pumped liquid may be scalding hot and under high pressure 4 1 Applications COMFORT pumps are designed for use in domestic hot water systems The pumps are suitable for open and closed system...

Страница 8: ...se observe the following Flush the system of debris before installation Refer to the arrows on the pump housing indicating the direction of the liquid flow through the pump TM075626 Always install the pump with horizontal motor shaft TM075625 Installation positions 8 English US ...

Страница 9: ...ped liquid may be scalding hot and under high pressure The arrows on the pump housing indicate the flow direction through the pump 1 Close the isolating valves and make sure that the system is not pressurized during the installation of the pump TM075632 2 Mount the pump with gaskets in the pipes with the motor shaft horizontally TM075633 9 English US ...

Страница 10: ...3 Tighten the fittings TM075634 4 Switch on the pump Do not switch on the pump until the system has been filled with liquid and vented TM075637 10 English US ...

Страница 11: ...ate counterclockwise on the pump to release the sensor cable 2 Pull out the sensor cable to the desired length Do not pull the cable downwards The maximum cable length is 8 ft 2 5 m TM075628 3 Install the temperature sensor on the pipes on the hot water outlet side The sensor must be installed 8 to 20 inches 20 to 50 cm A from the heat source and can be installed maximum 8 ft 2 5 m B from the pump...

Страница 12: ...witched on accidentally WARNING Hot surface Death or serious personal injury At high liquid temperatures the product may become so hot that only the operating panel must be touched to avoid burns Close the isolating valves on all sides of the product and then drain it Wear protective gloves To change the orientation of the pump head do as follows 1 Use a wrench to loosen the union TM075635 12 Engl...

Страница 13: ...s TM075636 5 Startup WARNING Hot surface Death or serious personal injury At high liquid temperatures the product may become so hot that only the operating panel must be touched to avoid burns WARNING Electric shock Death or serious personal injury Clean only the product with a dry cloth 13 English US ...

Страница 14: ...changing mode 5 Temperature control mode It lights up when the pump is running in temperature control mode To change the control mode on the pump press the button on the operating panel Press the button more times to change between the three available control modes AUTOADAPT This mode adapts the operating hours by switching on and off according to the tapping pattern of the users as detected by th...

Страница 15: ... Pos Description 1 Temperature control mode It lights up when the pump is running in temperature control mode 2 100 LED When lit the pump runs according to continuous 100 mode 3 Arrow button for changing mode To change control mode on the pump press the button on the operating panel Keep pressing the button to change between the two available control modes Temperature control The operating range o...

Страница 16: ...el LED It lights up when the actual time and operating time can be set 4 Actual time One LED equals a time interval of 30 minutes 5 Timer LEDs showing the pump s operating periods One LED equals a time interval of 30 minutes 6 Change button for toggling the actual time and timer LEDs 7 OK button for confirming changing or deleting settings 8 Activated timer function When lit the LED indicates that...

Страница 17: ...2 Move the actual timer LED by pressing the Change button until it indicates the actual time One LED equals a time interval of 30 minutes 3 Confirm by pressing OK 5 3 4 Setting the timer Once the actual time has been set the pump s timer LEDs become lit according to the default timer settings They are as follows 6 9 AM 06 00 09 00 11 AM 1 PM 11 00 13 00 4 9 PM 16 00 21 00 If you want to keep the d...

Страница 18: ...utes 4 Press the Arrow button to confirm the settings 5 3 5 Resetting to factory setting When resetting the timer all saved time periods will be lost 1 Press and hold the Arrow button for 5 seconds All LEDs light up after which the actual time LED blinks and the 100 LED is lit 18 English US ...

Страница 19: ...ARNING Electric shock Death or serious personal injury All electrical connections must be carried out by a qualified electrician in accordance with local regulations WARNING Electric shock Death or serious personal injury Excessive use of water when cleaning the product may cause the product to short circuit WARNING Pressurised system Death or serious personal injury Drain the system or close the ...

Страница 20: ...lves on all sides of the product and wait for the product to cool down before working on it WARNING Hot liquid Death or serious personal injury The pumped liquid may be scalding hot and under high pressure Close the isolating valves on all sides of the product and then drain it CAUTION Crushing of feet Minor or moderate personal injury Wear safety shoes when handling the product 20 English US ...

Страница 21: ...ce the pump 7 2 Defective internal temperature sensor The red error LED indicator is turned on during AUTOADAPT and does not go off when the pump is switched manually to temperature control mode Cause The internal temperature sensor is defective Per default the pump uses the external temperature sensor for the temperature control mode Remedy Replace the pump 7 3 Actual time LED is blinking only CO...

Страница 22: ... the operating periods are according to the needs Check if the impeller is blocked 7 5 No instant hot water No instant hot water Cause The pump is running Remedy Check if the return line or pump is air bound dry running Check the water heater aggregate 22 English US ...

Страница 23: ...ude max 6500 ft 2000 m 1 The ambient temperature must always be lower than the liquid temperature to minimize condensation in the stator housing and not exceed 104 F 40 C 9 Disposing of the product 1 Use the public or private waste collection service 2 If this is not possible contact the nearest Grundfos company or service workshop See also end of life information at www grundfos com product recyc...

Страница 24: ...UNDFOS CBS Inc 902 Koomey Road Brookshire TX 77423 USA Phone 281 994 2700 Toll Free 1 800 955 5847 Fax 1 800 945 4777 Canada GRUNDFOS Canada Inc 2941 Brighton Road Oakville Ontario L6H 6C9 Tel 1 905 829 9533 Fax 1 905 829 9512 Mexico Bombas GRUNDFOS de México S A de C V Boulevard TLC No 15 Parque Industrial Stiva Aeropuerto Apodaca N L 66600 Tel 52 81 8144 4000 Fax 52 81 8144 4010 Revision Info La...

Страница 25: ...ademarks displayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2020 Grundfos Holding A S all rights reserved ...

Отзывы: