Product description
17 | 80
B
A
_
T
D3
-B
S
0
0
1
e
n
_
0
1
4
_
so
ft
liQ
-SD
3.8
Inputs and outputs of the control unit
The control unit features voltage-free inputs and outputs. The functions are described in
chapter 6.9.
3.8.1
Data circuit board (only with softliQ:SD21 and softliQ:SD23)
Item
Description
Item
Description
1
LAN connection
2
iQ-Comfort 1
(for networking Grünbeck products)
3
iQ-Comfort 2
(for networking Grünbeck products)
4
Water sensor (digital input)
If another function is required for the digital input, the water sensor must be disconnected.
Cables LiYY 2x0.5 mm² or comparable should be used as connecting line. A larger line
cross-section is unsuitable.
Water sensor pin assignment (digital input):
● Terminal top + terminal middle = water sensor
● Terminal terminal middle = regeneration triggering or regeneration lock
No voltage signals are allowed to be applied to any of the 3 terminals.