Страница 1: ...We understand water Dosing system exaliQ KC6 e SC6 e SCxx Operation manual...

Страница 2: ...t of this instruction may be reproduced in any way without the written permission of Gr nbeck Wasseraufbereitung GmbH nor may any part be processed duplicated or disseminated using electronic systems...

Страница 3: ...upply 18 4 4 Installing the product 19 5 Start up 26 5 1 Preparations 26 5 2 Connecting container 32 5 3 How to start up the product 35 5 4 Handing over the product to the owner user 35 6 Operation 36...

Страница 4: ...h for your personal safety This symbol identifies instructions that you must comply with in order to avoid damage to property This symbol identifies important information about the product or its hand...

Страница 5: ...ction Multi step and chronological sequence of action steps important 1 First action a first step b second step 2 Second action Result after a handling instruction 3 Result Lists List item List sub it...

Страница 6: ...tion Item Designation 1 CE mark 2 DVGW test mark registered for testing 3 Disposal information 4 Observe operation manual 5 Nominal pressure 6 Operating range 7 Operating pressure 8 Ambient temperatur...

Страница 7: ...pply Safety devices must never be removed bridged or otherwise tampered with Do not operate any products which have a damaged power supply cable This can lead to injuries due to electric shock Have da...

Страница 8: ...that property damage can occur 2 3 Regulations Comply with the following regulations and directives amongst others during installation and start up Statutory regulations on environmental protection Pr...

Страница 9: ...uct as intended Make sure that the required inspection and maintenance work is carried out Keep this instruction 2 6 Product specific safety instructions Lay lines such as dosing line mains cable iQ C...

Страница 10: ...e used for hardness stabilisation pH value increase of drinking water and corrosion protection of pipes as well as for the renovation of old pipes with rust brown water The dosing system exaliQ K6 e a...

Страница 11: ...g panel with LED buttons 14 Illuminated LED ring 15 Door 16 Circuit board cover 17 USB interface sticker 18 Pump 3 4 Functional description A contact water meter with pulse generator records the volum...

Страница 12: ...pact unit with 3 l bottle exaliQ KC6 e exaliQ as suction lance device with 15 l canister exaliQ SC6 e 10 20 30 exaliQ as suction lance device with 60 l canister conversion kit for 60 litre suction lan...

Страница 13: ...ination with a water softener Refer to software instructions TD3 BS002 Cloud connection softliQ www gruenbeck de de werde wasser wisser faq Registration extends your warranty by 1 year 3 6 Accessories...

Страница 14: ...r water hardness 21 dH a water softener e g softliQ SD21 is recommended for hardness treatment Subsequent changeover to exaliQ safe exaliQ pure Hardness stabilization Galvanized pipes and copper mater...

Страница 15: ...able 1 canister is sufficient for approx 150 m3 drinking water treatment exaliQ control 114 071 exaliQ safe 114 072 exaliQ safe 114 073 exaliQ pure 114 074 exaliQ neutra 114 075 60 l plastic canister...

Страница 16: ...tervention into the drinking water system and only a specialist installer should install these systems 4 1 Installation examples 4 1 1 Stand alone use exaliQ KC6 SC6 SCxx wall mounting Item Designatio...

Страница 17: ...nking water filter pureliQ 3 Garden water pipe 4 Water withdrawal point 4 1 3 exaliQ KC6 e SC6 e in combination with a water softener softliQ SD softliQ MD Item Designation Item Designation 1 Safety d...

Страница 18: ...oor drain suitable for the system size must be available at the installation site or a protection device e g protectliQ or a protection device with water stop of the same quality must be installed Dow...

Страница 19: ...ing pump exaliQ with suction lance 5 Fastening material with dosing valve 6 Operation manual 7 iQ Comfort cable version SC6 e Check the scope of supply for completeness and damage 4 4 Installing the p...

Страница 20: ...installed 4 4 2 Mounting the dosing valve 1 Unscrew the dummy plug Keep the dummy plug 2 Screw in the dosing valve finger tight 3 The water meter is prepared with the dosing valve mounted 4 Mount the...

Страница 21: ...exaliQ docx Position the support flat on a fixed wall surface Fasten the support with 2 screws and dowels Tighten the fastening screws evenly not too tight 5 The support is mounted on the wall surface...

Страница 22: ...the support to the water meter using the hexagon head bolts 1 Adjust the threaded rod flush with the contact surface 2 Secure the threaded rod with the lock nut 3 Turn the counterholder to the wall su...

Страница 23: ...Installation 23 68 BA_TD3 CK000en_024_exaliQ docx Fastening to different water meters...

Страница 24: ...ith the support from above 2 Carefully slide the dosing system onto the support from above until it clicks The support is secured against removal with the interlock 4 4 5 Supporting the dosing system...

Страница 25: ...ctricity dosing pulse can be torn off if necessary disconnect them beforehand 2 Press and hold the release button CAUTION Sharp edged components short distance to the water meter Crushing abrasion of...

Страница 26: ...ning the door 1 Press the release button firmly until the door pops open 2 Swivel the door open 5 1 2 Connect dosing line NOTE Incorrect installation of the dosing line over hot sharp edged surfaces F...

Страница 27: ...n 1 Determine the required length of the dosing line depending on the installation situation 2 Push the union nut collet and O ring on the dosing line 3 Shorten the dosing line 4 Insert the end of the...

Страница 28: ...osing system 1 Feed the pulse cable of the water meter through the opening in the housing without pulling or kinking it 2 Thread the pulse cable with the plug through the slot of the door 3 Loosen the...

Страница 29: ...the plug into one of the 3 slots Closing cover 1 Slide the circuit board cover in from above 2 Make sure that the cables are not squashed 3 Secure the cover using the Torx screw do not tighten too ti...

Страница 30: ...D from SD21 softliQ MD 1 Feed the iQ Comfort cable through the opening in the housing without pulling or kinking it 2 Thread the iQ Comfort cable with the plug into the slot of the door 3 Remove the c...

Страница 31: ...nual softliQ SD or softliQ MD 7 Make sure that the dip switch is switched to On left position The iQ Comfort connection between dosing pump and water softener is established The dosing signals are tra...

Страница 32: ...Q neutra use eye protection goggles sturdy clothing and protective gloves Observe the safety data sheets and follow the instructions Before opening a container pay attention to the following Type of m...

Страница 33: ...ert the bottle from below onto the suction lance until it stops a See the mounting sticker on the 3 litre bottle b Make sure that the stop is positioned correctly left side 4 Turn the bottle one turn...

Страница 34: ...cap 2 Keep the screw cap to close the container after use 3 Insert the suction lance into the canister from above without kinks 4 Fix the suction lance with the sliding cover The suction lance of the...

Страница 35: ...is now ready for use The LED lights up continuously 3 Check that the appliance is dosing correctly when water is removed The illuminated LED ring lights up and pump noises can be heard 5 4 Handing ov...

Страница 36: ...ng elements and display 6 1 1 Illuminated LED ring In the standard setting the illuminated LED ring behaves as follows Lights up for Water treatment Dosing volume test Intermittent flashing for Pre em...

Страница 37: ...white Lights up when buzzer is deactivated Button Activating deactivating the buzzer LED red Lights up when an alarm signal or motor short circuit has occurred Button Acknowledgement Device is set to...

Страница 38: ...mainly intended for the specialist installer to carry out maintenance 6 2 1 App functions General functions Installer registration in the app Product registration Functions for exaliQ Display of produ...

Страница 39: ...Gr nbeck apps can be found on the Internet at the following address www gruenbeck de infocenter apps 6 3 Reading out saving dosing data The exaliQ control unit continuously records the dosing data ov...

Страница 40: ...hing Not illuminated with little data shorter than one second The data transfer has not been carried out completed correctly Data was transferred successfully or no data transfer takes place The data...

Страница 41: ...at www gruenbeck de Dosing agent table exaliQ exemplary Mineral based solutions Enter the dosing agent and container used mark with a cross Dosing agent Added mineral substances mg l Container 3 l Co...

Страница 42: ...st be changed when Expired shelf life of the mineral based solution After the container is opened it is recommended that the content should be used up within 6 months and within 12 months at most Afte...

Страница 43: ...tainer with mineral based solution is available Order a new mineral based solution from your dealer see chapter 3 7 Mineral based solutions 6 4 2 Replace 3 l bottle 1 Turn the bottle one turn clockwis...

Страница 44: ...n lance out upwards 3 Pay attention to hygiene do not touch the suction lance with your hands 4 Close the empty container with the screw cap An empty container can be disposed of in an environmentally...

Страница 45: ...k A maintenance contract ensures that all the required maintenance work will be performed in due time Only use genuine spare and wearing parts from Gr nbeck 7 1 Cleaning 7 1 1 Cleaning the dosing syst...

Страница 46: ...nal reliability of your product Conduct an inspection at least every 2 months Proceed as follows 1 Check whether the dosing system is in operating mode and does not report any faults 2 Check the dosin...

Страница 47: ...the dosing valve 2 Perform a dosing volume test 3 Evaluate the dosing data 4 Carry out a wear test on safety relevant components 7 5 Consumables Product Order no Mineral based solution in 3 l bottle...

Страница 48: ...ording to the flushing instructions 7 6 1 Flushing instructions 1 Connect a container with drinking water that complies with the drinking water regulations 2 Flush until the water consumption of appro...

Страница 49: ...lkatalog 7 8 Wearing parts Wearing parts are only allowed to be carried out by a specialist see technical service manual TD4 CK000 of the exaliQ dosing system NOTE If the pump unit is worn out underdo...

Страница 50: ...operating panel As soon as a fault appears LED lights up red proceed as follows Press to acknowledge the fault If the fault signal goes out the dosing system can continue to be operated Contact the cu...

Страница 51: ...talline deposits and contamination of parts that come into contact with media Flush the dosing system thoroughly Change the valves or the complete pump Change the dosing valve Clean or replace the hos...

Страница 52: ...sh to temporarily shut down your water supply due to a longer period of absence proceed as follows 1 Close the shut off valve downstream of the dosing system 2 Leave the raw water shut off valve open...

Страница 53: ...y put a dummy plug in the water meter fitting 10 2 Disposal Comply with the applicable national regulations 10 2 1 Packaging Dispose of the packaging in an environmentally sound manner 10 2 2 Product...

Страница 54: ...onnection diameter DN 25 1 Type of contact dosing signal Hall impulse iQ Comfort Protection protection class IP 43 Rated voltage range V 100 240 Rated frequency Hz 50 60 Electrical power input standby...

Страница 55: ...contact dosing signal Hall impulse iQ Comfort Protection protection class IP 43 Rated voltage range V 100 240 Rated frequency Hz 50 60 Electrical power input standby W 3 Electrical power input operati...

Страница 56: ...Technical specifications 56 68 BA_TD3 CK000en_024_exaliQ docx 11 3 exaliQ SC10 SC20 SC30 exaliQ SC10 exaliQ SC20 exaliQ SC30...

Страница 57: ...Performance data exaliQ SC10 exaliQ SC20 exaliQ SC30 Operating range max short term peak flow rates m h 10 20 30 Nominal pressure PN 10 Pressure loss at max flow bar 0 55 0 8 0 8 Container volume l 15...

Страница 58: ...ng water filter make type Drain connection acc to DIN EN 1717 yes no Floor drain available yes no Safety device yes no Dosing active ingredient exaliQ Operating values Water pressure flow pressure bar...

Страница 59: ...r meter reading with without garden pipe m Read out error memory Error Date Time 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Maintenance work OK Hose connections checked for leaks and damage Whole of dosing s...

Страница 60: ...r meter reading with without garden pipe m Read out error memory Error Date Time 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Maintenance work OK Hose connections checked for leaks and damage Whole of dosing s...

Страница 61: ...r meter reading with without garden pipe m Read out error memory Error Date Time 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Maintenance work OK Hose connections checked for leaks and damage Whole of dosing s...

Страница 62: ...r meter reading with without garden pipe m Read out error memory Error Date Time 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Maintenance work OK Hose connections checked for leaks and damage Whole of dosing s...

Страница 63: ...r meter reading with without garden pipe m Read out error memory Error Date Time 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Maintenance work OK Hose connections checked for leaks and damage Whole of dosing s...

Страница 64: ...meter reading with without garden pipe m Read out error memory Error Date Time 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Maintenance work OK Hose connections checked for leaks and damage Whole of dosing sy...

Страница 65: ...no refer to type plate The aforementioned system also complies with the following directives and provisions Directive on the Restriction of Hazardous Substances RoHS 2011 65 EC Electrical and Electro...

Страница 66: ...34 44 Inspection maintenance intervals 46 Installing the connection flange 19 IQ Connect cable 30 M Mineral based solution consumables 47 Mineral based solutions 14 Mounting the dosing unit 24 mySett...

Страница 67: ......

Страница 68: ...Gr nbeck Wasseraufbereitung GmbH Josef Gr nbeck Str 1 89420 Hoechstaedt Germany For more information go to www gruenbeck com 49 9074 41 0 49 9074 41 100 info gruenbeck com www gruenbeck com...