background image

2

GK2EW50120B_G    Revision date: 12.06.19

Important Information

END FRAME KIT: HOW TO USE THIS GUIDE

After assembling building main frame, attach steel end frame. Read this 

section to learn how best to use this guide. 

Not all pages apply to your end 

wall frame. The phrase Ground Post Option used in this guide refers to 

end frames that do not include base plates.

• 

(B) Base Plate Diagrams:

 Used when end wall frame includes vertical 

supports and base plates that will be anchored to a concrete slab or 

concrete piers.

• 

(G) Without Base Plate Diagrams: 

Used when end wall frame includes 

vertical supports that will be set below grade and anchored in place using 

customer-supplied concrete. 

 

 

ROUGH DOOR OPENING: 

Materials are included to frame an opening for 

a pedestrian door. If a door will not be installed in the end wall, C-channel 

material is not used. Always confirm rough opening dimensions by reading 

the documentation included with door and by measuring the actual door 

before anchoring

 any framing in concrete.

ATTENTION:

 Customer/contractor is responsible for installing end framing 

to install door. Consult a qualified contractor to assist in framing an opening 

and to complete door installation if needed. Additional purchase required for 

doors and end wall cladding kits. Consult documentation with those items for 

additional details.

REQUIRED TOOLS

The following list identifies the main tools needed to assemble end frame.

 

Additional tools and supports may be needed depending on the structure, 

location, and application.

•  Tape measure or measuring device
•  Marker to mark the location on tubing.
•  Variable speed drill and impact driver (cordless with extra batteries works 

best) 

•  Metal file and metal-cutting saw
•  Wrenches and impact socket set
•  Hammers, gloves, and eye protection
•  Adjustable pliers and self-locking pliers
•  Ladders, work platforms, and other machinery for lifting designed to work 

safely at building and end frame height.

ATTENTION:

 Consult the services of a qualified, professional contractor if 

you are not familiar with constructing similar frame structures. 

The individuals assembling this end frame are responsible for designing 

and furnishing all temporary bracing, shoring and support needed during 

the assembly process. For safety reasons, those who are not familiar with 

recognized construction methods and techniques must seek the help of a 

qualified contractor.

SAFETY PRECAUTIONS

•  Wear eye, hand, and head protection.
•  Use a portable GFCI (Ground Fault Circuit Interrupter) when working with 

power tools and cords.

•  Do not climb on framing during or after construction.
•  Do not occupy the shelter during high winds, tornadoes, or hurricanes.
•  Provide adequate ventilation if the structure is enclosed.
•  Do not store hazardous materials in the shelter.
•  Provide proper ingress and egress to prevent entrapment. 

READ THIS DOCUMENT BEFORE YOU BEGIN

Thank you for purchasing this GrowSpan™ Series 2000 Steel End Frame 

Kit. When properly assembled and maintained, this product will provide years 

of reliable service. These instructions include helpful hints and important 

information needed to safely assemble and properly maintain the end frame. 

Please read these instructions 

before

 you begin.

If you have any questions during the assembly, contact Customer Service for 

assistance.

Содержание 2000 Series

Страница 1: ...te 12 06 19 2019 GrowSpan All Rights Reserved Reproduction is prohibited without permission 50 Wide GrowSpan Series 2000 Steel End Frame Kits STK GK2EW50120B 50 Wide Base Plates GK2EW50120G 50 Wide No Base Plates ...

Страница 2: ... measuring device Marker to mark the location on tubing Variable speed drill and impact driver cordless with extra batteries works best Metal file and metal cutting saw Wrenches and impact socket set Hammers gloves and eye protection Adjustable pliers and self locking pliers Ladders work platforms and other machinery for lifting designed to work safely at building and end frame height ATTENTION Co...

Страница 3: ...e you do not need to open the plastic bags containing smaller parts such as fasteners and clamps CARE AND MAINTENANCE Proper care and maintenance is important Check these items periodically Inspect all components regularly and frequently Check connections and all fasteners to verify they remain tight and in good repair Do not climb or stand on shelter or end frame Remove debris and objects that ma...

Страница 4: ... 7 1 2 7 4 1 2 14 4 1 2 21 4 1 2 29 4 1 2 36 4 1 2 43 4 1 2 50 1 1 2 50 7 1 2 4 1 2 7 4 1 2 14 4 1 2 21 4 1 2 29 4 1 2 36 4 1 2 43 4 1 2 50 9 PLATE EDGE PLATE CENTERS ANCHOR HOLE CENTERS SECTION A A 111817 DETAIL OPTIONAL 3 6 5 1 2 8 7 8 TYP 1 1 4 NOTE USE PLATE CENTERS FOR GROUND POST APPLICATION A A ...

Страница 5: ...NS ARE FROM CENTER TO CENTER UNLESS OTHERWISE NOTED GIRTS FRAMING CHANNEL MAY REQUIRE FIELD CUTTING TO FIT ENDWALL COLUMNS GIRT DOOR FRAME GT GRT2X2G16L144 16 GA PROFILE T 2X PGBRKAAS01 CONNECTION PLATE COLUMN TOP CONNECTION PLATE 111817 BASE PLATE B COLUMN BOTTOM BASE PLATE LATERAL BRACING BRACKET LB QH1070 PIPE STRAP C3 PG2X4EC14L24331 2 x 4 14 GA 1 PLY RECT TUBE PG2X4EC14L15913 2 x 4 14 GA 1 PL...

Страница 6: ...L TOP OF POST B LB LB T T T C2 C2 C1 C3 C3 T T B B B B GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT 50 0 GRT2X2G16L144 16 GA PROFILE GT GIRT DOOR FRAME ENDWALL COLUMNS H1 105488 2 C CHANNEL DB QH1330 FRAME BRACKET C1 C2 PG2X4EC14L21000 2 x 4 14 GA 1 PLY RECT TUBE PG2X4EC14L15913 2 x 4 14 GA 1 PLY RECT TUBE COLUMN BOTTOM BASE PLATE B 111817 BASE PLATE COLUMN TOP CONNEC...

Страница 7: ... 4 14 GA 1 PLY RECT TUBE PG2X4EC14L21000 2 x 4 14 GA 1 PLY RECT TUBE C2 C1 NOTES ALL DIMENSIONS ARE FROM CENTER TO CENTER UNLESS OTHERWISE NOTED GIRTS FRAMING CHANNEL MAY REQUIRE FIELD CUTTING TO FIT B T C1 GT LB LB GROUND LEVEL TOP OF POST B LB LB T T T C2 C2 C1 C3 C3 T T B B B B GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT 50 0 Vent End Frame Diagram B IMPORTA...

Страница 8: ...8 GK2EW50120B_G Revision date 12 06 19 End Frame G Vertical Supports Layout 7 0 8 0 7 0 7 0 7 0 7 0 7 0 50 0 Concrete to anchor vertical supports required ...

Страница 9: ... CONNECTION PLATE COLUMN TOP CONNECTION PLATE N A B COLUMN BOTTOM GROUND POST INSERT LATERAL BRACING BRACKET LB QH1070 PIPE STRAP C1 C2 PG2X4EC14L21000 2 x 4 14 GA 1 PLY RECT TUBE PG2X4EC14L18375 2 x 4 14 GA 1 PLY RECT TUBE PG2X4EC14L24331 2 x 4 14 GA 1 PLY RECT TUBE C3 T C1 GT LB LB GROUND LEVEL TOP OF POST LB LB T T T C2 C2 C1 C3 C3 T T GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT...

Страница 10: ... PROFILE GT GIRT DOOR FRAME ENDWALL COLUMNS H1 105488 2 C CHANNEL COLUMN BOTTOM GROUND POST INSERT B N A COLUMN TOP CONNECTION PLATE T 2X PGBRKAAS01 CONNECTION PLATE QH1070 PIPE STRAP LB LATERAL BRACING BRACKET C3 PG2X4EC14L24331 2 x 4 14 GA 1 PLY RECT TUBE PG2X4EC14L18375 2 x 4 14 GA 1 PLY RECT TUBE PG2X4EC14L21000 2 x 4 14 GA 1 PLY RECT TUBE C2 C1 T C1 GT VERIFY DOOR ROUGH OPENING H1 DB DB LB LB...

Страница 11: ...E PG2X4EC14L21000 2 x 4 14 GA 1 PLY RECT TUBE C2 C1 NOTES ALL DIMENSIONS ARE FROM CENTER TO CENTER UNLESS OTHERWISE NOTED GIRTS FRAMING CHANNEL MAY REQUIRE FIELD CUTTING TO FIT T C1 GT LB LB GROUND LEVEL TOP OF POST LB LB T T T C2 C2 C1 C3 C3 T T GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT GT 50 0 Vent End Frame Diagram G ATTENTION See End Frame Connections Detail...

Страница 12: ...n date 12 06 19 VIEW 1 COLUMN TO BASE PLATE GIRT BASE PLATE OPTION VIEW 1A COLUMN TO GIRT GROUND POST OPTION VIEW 2 COLUMN TO TOP CHORD VIEW 3 COLUMN TO GIRT NON SPLICE VIEW 4 LATERAL BRACE TO COLUMN End Frame Connections B G ...

Страница 13: ...E PLATE 111817 1X 1 2 X 3 HEX BOLT A325 2X 1 2 WASHER STRUCTURAL 1X 1 2 NUT STRUCTURAL 4X 14 X 1 TEK SCREW ENDWALL GIRT ENDWALL GIRT ENDWALL COLUMN TOP CHORD ENDWALL COLUMN 2X CONNECTION PLATE PGBRKAAS01 2X 1 2 X 3 HEX BOLT A325 4X 1 2 WASHER STRUCTURAL 2X 1 2 NUT STRUCTURAL VIEW 2 COLUMN TO TOP CHORD NOTE FIELD DRILL 1X 9 16 HOLE THRU BOTH WALLS OF TOP CHORD 1X BRACKET QH1070 3X 14 X 1 TEK SCREW ...

Страница 14: ...ON VIEW 2 DOOR HEADER TO JAMB ONLY APPLIES TO DOOR ENDWALL OPTION VIEW 3 DOOR JAMB ANCHOR GIRT BASE PLATE OPTION ONLY APPLIES TO DOOR ENDWALL OPTION ATTENTION Actual position of QH1330 bracket may differ and depends on how purchased door is secured to door frame End Frame Connections Door Option B G ...

Страница 15: ... FIELD TO FIT SO TAB SITS FLUSH AGAINST GIRT ENDWALL GIRT 2X WAFER HEAD SCREW 10 X 3 4 DOOR JAMB C CHANNEL DOOR HEADER C CHANNEL NOTE THIS PART TO BE CUT IN FIELD TO FIT 1X 14 X 1 TEK SCREW 1X 14 X 1 TEK SCREW 2X WAFER HEAD SCREW 10 X 3 4 2X WAFER HEAD SCREW 10 X 3 4 NOTE BEND TAB UP 90 DOOR JAMB C CHANNEL ENDWALL GIRT 1X BRACKET QH1330 2X 14 X 1 TEK SCREW 2X WAFER HEAD SCREW 10 X 3 4 NOTE FEILD C...

Страница 16: ...T MAX 12 O C NOTE POLYURETHANE SEALANT TO BE USED BASE OF ALUMINUM TUBE GIRT BASE PLATE OPTION COLUMN 1 X 1 1 2 ALUMINUM TUBE 113301 FOR USE WITH BASE PLATE OPTION ONLY Aluminum Angle Installation Option Base Plates Only B PANEL ATTACH PANEL TO OUTSIDE OF GIRT AND ALUMINUM IN SOME INSTANCES ALUMINUM ANGLE IS REPLACED WITH 113301 ALUMINUM TUBING SEE NEXT PAGE ATTENTION INSTALL BOTTOM RUN OF GIRT AF...

Страница 17: ...PTION COLUMN 1 X 1 1 2 ALUMINUM TUBE 113301 FOR USE WITH BASE PLATE OPTION ONLY ALUMINUM TUBE 113301 ENDWALL COLUMN BASE PLATE ENDWALL GIRT ENDWALL COLUMN SECTION A A GLAZING LINE Aluminum Square Tube Installation Option Base Plates Only B PANEL ATTENTION INSTALL BOTTOM RUN OF GIRT AFTER INSTALLING THE TUBING PRE DRILL MOUNTING HOLES IN ALUMINUM SPACE AT 12 16 ON CENTER APPLY SEALANT 112263 UNDER ...

Отзывы: