Instruction manual
GROW
BASE EC
PRO
12
displayed.
To delete the warning and return to
operation in CO
₂
mode, press the button
while this screen is displayed.
1.1
Current fan speed intake
This screen shows the current rpm/power of
the intake fan. The “percent value”
represents the power transmitted to the fan.
The “rpm value” indicates the fan’s actual
rpm. The rpm is detected from EC fans only.
If the percent value alternates between a
number (e.g. 15%) and “off”, it means that a
connected EC fan is driven on 15% and a
standard duct fan is turned off. Please find
further details in sections “2.8 Intake fan
turnoff day” and “2.12 Intake fan turnoff
night”.
rpm = revolutions per minute
1.2
Current fan speed exhaust
This screen shows the current rpm/power of
the exhaust fan. The “percent value”
represents the power that is transmitted to
the fan.
1.3
Functions of outputs
This displays shows the chosen output
functions
of the
sockets
“Multifunctional
Out 1-4” (Out1-Out4). If an output extender
is connected, additional outputs are
displayed according to the number of
outputs.
1.9
Interval info
This display shows the
remaining time
for
switching an output for which the function
“interval”
is selected to switch-on or
switch-off.
1.10
Info Clock/Mode
This display shows the
current time
and
whether the current mode is on “
day”
or
“
night”
. This is determined by the time set
for “lights on” and “lights off” for the clock
timer.
(See also menu “
Setup” “2.22/2.23 Lights
ON/OFF”
) ON=Begin of day, OFF=Begin of
night.
While the CO
₂
control is active, “CO2” is
displayed. The CO
₂
function only operates
during “daytime”.
1.11
Enter “setup”
To enter
menu level 2 “setup”
, press the
rotary switch while this screen is displayed.
Press to
F
enter menu
BC
12
C34C56
i
Mode
C
Day
BC
Intervall ON
i
in
C
00
C10C54
BC
Out1
C
Exhaust i
Out2
C
Intake
BC
rpm exhaustC
i
2876rpm
72
A
BC
rpm intakeC
i
2476rpm
62
A