Two inverters in each phase: 

Power Connection 

 

 

 

Communication Connection 

 

 

 

Three inverters in one phase, two inverters in second phase and one inverter for the third phase: 

Power Connection 

 

 

 

Communication Connection 

 

 

 

Содержание SPF 3000TL LVM

Страница 1: ...Off Grid Solar Inverter SPF 3000TL LVM Version 4 0 User Manual...

Страница 2: ...gnal 11 Operation 12 Power ON OFF 12 Operation and Display Panel 12 LCD Display Icons 13 LCD Setting 15 Display Setting 20 Operating Mode Description 23 Parallel Installation Guide 25 Introduction 25...

Страница 3: ...circuited Do NOT connect to the mains when DC input short circuits 4 NEVER charge a frozen battery 5 Do not disassemble the unit Take it to a qualified service center when service or repair is requir...

Страница 4: ...lity grid Please consult with your system integrator for other possible system architectures depending on your requirements The WiFi GPRS module is a plug and play monitoring device to be installed on...

Страница 5: ...off switch 12 Battery input 13 Parallel communication ports only for parallel model 14 Current sharing ports only for parallel model 15 AC output 16 Circuit breaker 18 RS485 communication port for ex...

Страница 6: ...screws as shown below Mounting the Unit Consider the following points before selecting where to install Do not mount the inverter on flammable construction materials Mount on a solid surface Install...

Страница 7: ...2 6AWG 28 6 4 33 2 SPF 3000TL LVM 48P 71A 100AH 1 4AWG 22 6 4 39 2 2 3 Nm 200AH 2 8AWG 16 6 4 33 2 Note for lead acid battery the recommended charge current is 0 2C C battery capacity Please follow b...

Страница 8: ...he end of RJ45 of battery to BMS communication port RS485 or CAN of inverter 4 The other end of RJ45 insert to battery communication port RS485 or CAN Note If choosing lithium battery make sure to con...

Страница 9: ...DC cut off voltage can be set up in program 19 20 and 21 User Defined 2 suitable when lithium battery without BMS communication If User Defined 2 is selected battery charge voltage and low DC cut off...

Страница 10: ...municate with BMS in a parallel system you should make sure to connect the BMS communication cable between the battery and one inverter of the parallel system It s recommended to connect to the master...

Страница 11: ...size as below Suggested cable requirement for AC wires Model Gauge Torque Value SPF 3000TL LVM 8 AWG 1 4 1 6 Nm Please follow below steps to implement AC input output connection 1 Before making AC in...

Страница 12: ...w below steps to implement PV module connection 1 Remove insulation sleeve 10 mm for positive and negative conductors 2 Check correct polarity of connection cable from PV modules and PV input connecto...

Страница 13: ...panel It could be used to deliver signal to external device when battery voltage reaches warning level Unit Status Condition Dry contact port NC C NO C Power Off Unit is off and no output is powered...

Страница 14: ...ut power information 1 LCD display 2 Status indicator 3 Charging indicator 4 Fault indicator 5 Function buttons LED Indicator LED Indicator Messages Green Solid On Output is powered by utility in Line...

Страница 15: ...level by 0 24 25 49 50 74 and 75 100 in battery mode and charging status in line mode These two signs indicate the charge priority SOLAR indicates solar first UTILITY indicate utility first SOLAR blin...

Страница 16: ...overload Indicates the load level by 0 24 25 49 50 74 and 75 100 0 24 25 49 50 74 75 100 Mode Operation Information Indicates unit connects to the mains Indicates unit connects to the PV panel Indicat...

Страница 17: ...vides power to the loads as first priority If solar energy is not sufficient to power all connected loads battery energy will supply power to the loads at the same time Utility provides power to the l...

Страница 18: ...ed 2 suitable when lithium battery without BMS communication If User Defined 2 is selected battery charge voltage and low DC cut off voltage can be set up in program 19 20 and 21 It is recommended to...

Страница 19: ...Fault mode charger source can be programmed as below Solar first Solar energy will charge battery as first priority Utility will charge battery only when solar energy is not available Utility first U...

Страница 20: ...cted solar input power will be automatically adjusted according to the following formula Max input solar power Max battery charging power Connected load power Solar power balance disable If selected t...

Страница 21: ...min Settable 46 Battery equalized timeout Default 120min 5min 900min Settable 47 Equalization interval Default 30days 1 days 90 days Settable 48 Equalization activated immediately Equalization activat...

Страница 22: ...power battery voltage output voltage output frequency load percentage load in VA load in Watt DC discharging current main CPU Version and second CPU Version Setting Information LCD display Input volt...

Страница 23: ...t 70 Load in VA When connected load is lower than 1kVA load in VA will present xxx VA like below chart When load is larger than 1kVA 1kVA load in VA will present x x kVA like below chart Load in Watt...

Страница 24: ...22 Main CPU version checking Main CPU version 502 00 719 Secondary CPU version checking Secondary CPU version 002 00 719 Battery SOC Battery SOC 80...

Страница 25: ...when connected load is pretty low or not detected No output is supplied by the unit but it still can charge batteries Charging by utility and PV energy Charging by utility Charging by PV energy No cha...

Страница 26: ...y at line mode Charging by PV energy Line Mode The unit will provide output power from the mains It will also charge the battery at line mode Charging by utility Battery Mode The unit will provide out...

Страница 27: ...ote If the package includes share current cable and parallel cable the inverter is default supported parallel operation You may skip section 3 If not please purchase parallel kit and install this unit...

Страница 28: ...communication board Step 5 Remove two screws as below chart to take out cover of parallel communication Step 6 Install new parallel board with 2 screws tightly Step 7 Re connect 2 pin and 14 pin to o...

Страница 29: ...ry to cause parallel inverters not working Recommended AC input and output cable size for each inverter Model AWG no Torque SPF 3000TL LVM 8 AWG 1 4 1 6Nm You need to connect the cables of each invert...

Страница 30: ...can use 50A breaker for only 1 unit and each inverter has a breaker at its AC input Note2 Regarding three phase system you can use 4 poles breaker the rating is up to the current of the phase which ha...

Страница 31: ...29 Three inverters in parallel Power Connection Communication Connection Four inverters in parallel Power Connection Communication Connection...

Страница 32: ...30 Five inverters in parallel Power Connection Communication Connection Six inverters in parallel Power Connection Communication Connection...

Страница 33: ...Operation in Three Phase One inverter in each phase Power Connection Communication Connection Two inverters in one phase and only one inverter for the remaining phases Power Connection Communication...

Страница 34: ...two phases and only one inverter for the remaining phase Power Connection Communication Connection Three inverters in one phase and only one inverter for the remaining two phases Power Connection Comm...

Страница 35: ...o inverters in each phase Power Connection Communication Connection Three inverters in one phase two inverters in second phase and one inverter for the third phase Power Connection Communication Conne...

Страница 36: ...Connection Communication Connection WARNING Do not connect the current sharing cable between the inverters which are in different phases Otherwise it may damage the inverters Parallel Operation in Sp...

Страница 37: ...ction Communication Connection Three inverters in each phase Power Connection Communication Connection WARNING Do not connect the current sharing cable between the inverters which are in different pha...

Страница 38: ...warning 15 LCD display in Master unit LCD display in Slave unit Step 5 If there is no more fault alarm the parallel system is completely installed Step 6 Please switch on all breakers of Line wires i...

Страница 39: ...2P0 2P1 split phase 120V 208V 2P0 2P2 split phase 120V 240V Note It s necessary to turn off switch when setting LCD program Otherwise the setting can not be programmed Step 3 Turn on all units sequent...

Страница 40: ...ted by internal converter components 06 Output voltage is too high 07 Overload time out 08 Bus voltage is too high 09 Bus soft start failed 51 Over current or surge 52 Bus voltage is too low 53 Invert...

Страница 41: ...Beep once every second 16 Parallel input phase error Beep once every second 17 Parallel output phase loss Beep once every second 20 BMS communication error Beep once every second 33 BMS communication...

Страница 42: ...float stage when the setting equalization interval battery equalization cycle is arrived or equalization is active immediately the controller will start to enter Equalize stage Equalize charging time...

Страница 43: ...PS 65Vac 5V Appliances Low Loss Return Voltage 100Vac 5V UPS 70Vac 5V Appliances High Loss Voltage 140Vac 5V High Loss Return Voltage 135Vac 5V Max AC Input Voltage 150Vac Nominal Input Frequency 50Hz...

Страница 44: ...d 20 21 4Vdc 20 load 50 20 2Vdc load 50 44 0Vdc load 20 42 8Vdc 20 load 50 40 4Vdc load 50 Low DC Warning Return Voltage Lead Acid Mode 23 0Vdc load 20 22 4Vdc 20 load 50 21 2Vdc load 50 46 0Vdc load...

Страница 45: ...rve Battery Voltage per cell Charging Current 2 43Vdc 2 35Vdc Voltage 2 25Vdc 100 50 T0 T1 T1 10 T0 minimum 10mins maximum 8hrs Current Time Bulk Absorption Maintenance Constant Current Constant Volta...

Страница 46: ...eck whether the thermistor plug is loose Fault code 03 Battery is over charged Restart the unit if the error happens again please return to repair center The battery voltage is too high Check if spec...

Страница 47: ...8 settings are the same for all parallel inverters 3 Check whether the current sharing cables are connected well in the same parallel phases 4 Check whether all neutral wires of all parallel units are...