background image

48

 

47

 

 

14

 

Technical Data

 

14.1

 

Specification 

 

Model

 

Specifications

 

MIN 2500 

TL-XH

 

MIN 3000 

TL-XH

 

MIN 3600 

TL-XH

 

MIN 4200 

TL-XH

 

PV input quantities

 

Max. recommended PV 
power(for module STC)

 

5000W

 

6000W

 

7200W

 

8400W

 

Vmax PV

 

500V

 

550V

 

Start voltage

 

100V

 

Min. operating voltage 

70V 

Nominal voltage

 

360V

 

MPP voltage range

 

70-500V

 

70-500V

 

70-550V

 

70-550V

 

MPP voltage range at Full 
Power

 

95V-450V

 

115V-450V

 

140V-500V

 

160V-500V

 

No. of MPP trackers

 

2

 

No. of PV strings per 
MPP trackers

 

1

 

Max. input current per 
MPP trackers

 

13.5A

 

Max. short-circuit current 
per MPP trackers

 

16.9A

 

Max. inverter backfeed 
current to the array

 

0A

 

DC input quantities

 

Nominal DC input voltage

 

400V

 

DC input voltage range

 

360-500V

 

360-550V

 

DC input current(maximum 
continuous)

 

17A

 

DC output quantities

 

Nominal DC input voltage

 

400V

 

DC input voltage range

 

360-550V

 

DC input current(maximum 
continuous)

 

17A

 

Battery type

 

Lithium ion battery

 

AC output quantities

 

Rated output power 

2500W

 

3000W

 

3600W

 

4200W

 

Rated apparent power 

2500VA

 

3000VA

 

3600VA

 

4200VA

 

Nominal AC voltage

 

230V

 

AC voltage range

 

160-

276

V

 

Norminal AC grid frequency

 

50/60Hz

 

AC grid frequency range

 

45-55Hz/55-65Hz

 

Rated output current 

10.9A 

13A 

15.7A 

18.3A 

Max. output current

 

11.3A

 

13.6A

 

16A

 

19A

 

Max. inrush current 

(Peak value/duration time)

 

10A/5ms

 

 

62A/20us

 

Max.output overload 
protection

 

16A

 

16A

 

20A

 

25A

 

Backfeed current

 

0A

 

Power factor(@nominal power)

 

>0.99

 

Power factor range

 

0.8leading… 0.8lagging

 

THDi

 

 

AC grid connection type

 

Single phase(L/N/PE)

 

AC overvoltage category

 

Category III

 

AC input quantities

 

Nominal AC input voltage

 

230V

 

AC input voltage range

 

160-276V

 

AC input current(maximum 
continuous)

 

11.3A

 

13.6A

 

16A

 

19A

 

Inrush current

 

10A/5ms

 

Nominal frequency

 

50/60Hz

 

AC input frequency range

 

45-55Hz/55-65Hz

 

 

Max. efficiency

 

98.2%

 

98.2%

 

98.2%

 

98.4%

 

Euro-eta

 

97.1%

 

97.1%

 

97.2%

 

97.2%

 

 

DC reverse-polarity protection

 

Integrated

 

DC switch

*

 

Integrated

 

DC Surge protection class

 

 

Insulation resistance 
monitoring

 

Integrated

 

AC surge protection class

 

 

AC short-circuit protection

 

Integrated

 

Ground fault monitoring

 

Integrated

 

Grid monitoring

 

Integrated

 

Anti-islanding protection

 

Integrated(Active 

Frequency Drift)

 

Residual-current monitoring 
unit

 

Integrated

 

 

Содержание MIN 2500TL-XH

Страница 1: ...MIN 6000TL XH Download Manual Installation Operation Manual Growatt New Energy CO LTD 4 13 F Building A Sino German Europe Industrial Park Hangcheng Ave Bao an District Shenzhen P R China T 86 0755 27...

Страница 2: ...ngs TL XH overview Type label Size and weight Storage of inverter The advantage of theunit Validity Target group Additional information Symbols in this document Glossary Safety instructions Selecting...

Страница 3: ...erter Specification PV BAT AC connectors info Torque Accessories Start the inverter General setting Advanced setting Communication interfaces Startup the inverter Shutdown the inverter Checking heat d...

Страница 4: ...sponsibilities to inform the users 1 4 Symbols in this document 1 4 1 Warings in this document A warning describes a hazard to equipment or personnel It calls attention to a procedure or practice whic...

Страница 5: ...XH MIN 4200TL XH MIN 4600TL XH MIN 5000TL XH MIN 6000TL XH inverters are built according to all required safety rules Nevertheless improper use may cause lethal hazards for the operator or third part...

Страница 6: ...onnections e g conductor termination fuses PE connection etc in accordance with prevailing regulations When working with the inverter powered on adhere to all prevailing safety regulations to minimize...

Страница 7: ...r 3 2 Type label The type labels provide a unique identification of the inverter The type of product Device specific characteristics Certificates and approvals The type labels are on the left hand sid...

Страница 8: ...al package and should be stored in a clean and dry place and be protected from dust and water vapor corrosion The storage temperature should be always between 25 and 60 And the storage relative humidi...

Страница 9: ...olutely necessary Growatt assumes no responsibility for compliance to EMC regulations for the complete system All electrical installations shall be done in accordance with the local and national elect...

Страница 10: ...horizontal and avoids forward and sideways tilt Be sure that the inverter is out of the children s reach Don t put any things on the inverter Do not cover the inverter Do not install the inverter near...

Страница 11: ...ed the inverter on the wall WARNING Falling equipment can cause serious or even fatal injury never mount the inverter on the bracket unless you are sure that the mounting frame is really firmly mounte...

Страница 12: ...sidual current and protecting the inverter against residual current If an external RCD breaker is mandatory in the country of installation you must choose a Type A RCD breaker with the rating residual...

Страница 13: ...20 19 3 Push the threaded sleeve into the socket Tighten up the cap on the terminal 4 Finally Push or screw the threaded sleeve to connection terminal until both are locked tightly on the inverter...

Страница 14: ...the threaded sleeve then pull it out Wire suggestion length Conductor cross section Max cable length MIN 2500 TL XH MIN 3000 TL XH MIN 3600 TL XH 4 mm 12AWG 48m 40m 33m 5 2 mm 10AWG 60m 50m 42m Condu...

Страница 15: ...in paired male and female connectors The connectors for PV arrays and inverters are Helios H4 R VP D4 connectors Types Max current PV1 Max current PV2 Max voltage 2500 3000 TL XH 13 5A 13 5A 500V 3600...

Страница 16: ...rator or unrecoverable damage to the inverter Only qualified personnel can perform the wiring work Connection of BAT input terminal 4 6mm Cable Positive metal terminal Positive connector 6 5 Connectin...

Страница 17: ...6 AntiReFlux_B Connect meter signal RS485B 7 BAT_B Connect Battery communication RS485B or CANL 8 BAT_A Connect Battery communication RS485A or CANH CAUTION The communication interface RS485 or CAN be...

Страница 18: ...n is used to control the active or apparent power output levels of an inverter The export limit control function for an inverter is used to control the generation from an inverter to manage the export...

Страница 19: ...to inverter Meter Pin NO Description Meter Connection 1 CT input CT P White 2 CT N Black or Blue 3 N in Grid N 4 L in Grid L 9 RS485B RS485B2 connect to inverter SYS COM Pin 8 10 RS485A RS485A2 conne...

Страница 20: ...DRM8 are available CAUTION Damage to the inverter due to moisture and dust penetration Make sure the cable gland has been tightened firmly If the cable gland are not mounted properly the inverter can...

Страница 21: ...on t over 5V RRCR PCI Connector 6 9 2 1 The connector pin assignment and function definition Pin Assignment for inverters capable of both charging and discharging 12V GND DRM 1 5 DRM 2 6 DRM 3 7 DRM 4...

Страница 22: ...with a power of 300 W or greater must be interrupted by the AFCI within the time specified by UL 1699B A tripped AFCI can only be reset manually You can deactivate the automatic arc fault detection a...

Страница 23: ...n under VDE0126 1 1 for other region after 30s When inverter powered on OLED will light automatically Once the PV power is sufficient OLED displays the following Growatt PV inverter Country Aera XXXX...

Страница 24: ...o switch display Double touch to enter next stage menu Grid XXXvXXXHz Etotal XXXXw Etoday XXXkWh Power XXXXw Model S03B00D 00T00P00U00M0 000 FW Ver AK X X More Info Set parameter PV2 XXXvXXXXw PV1 XXX...

Страница 25: ...ing Set inverter date as described below 7 2 3 Set inverter date Single touch make the number up Double touch to confirm the setting Set inverter date as described below 7 2 4 Set inverter time Single...

Страница 26: ...ry Aera xxxxxxx Set OK Set parameter General Advanced Password Reset Region Set Region A B C NO YES Set OK Set parameter General Advanced Password Reset PQRM Set PQRM Volt Var Set PQRM xxxxxxx Set OK...

Страница 27: ...s three working modes Grid priority Battery priority and Load priority default is Load priority mode Users can set the inverter to work in different modes in different time periods through OLED Single...

Страница 28: ...ime3 Disable Multiple single Single touch Double touch touch LoadFirst NN 01 touch LoadFirst 00 NN touch 7 4 2 COM Port BatFirst 00 01 Time3 Disable Time3 Disable Time3 Disable The XH series inverter...

Страница 29: ...ts output power due to high temperature please improve the heat dissipation condition Maybe you need to clean the heat sink 9 2 Cleaning the Inverter If the inverter is dirty turn off the AC breaker D...

Страница 30: ...nverter please read through the following information to correct the problem 11 1 Error Messages displayed on OLED An error message will be displayed on the OLED screen when a fault occurs The faults...

Страница 31: ...k AC wiring especially neutral and ground wire 3 C h e c k g r i d f r e q u e n c y i s complied with local grid standard 4 Restart inverter if problem still exist Contact Growatt Auto Test Failed Er...

Страница 32: ...or electronic waste which apply at the installation site at that time Ensure that the old unit and where applicable any accessories are disposed of in a proper manner Wait 20 minutes before disassembl...

Страница 33: ...2500VA 3000VA 3600VA 4200VA Nominal AC voltage 230V AC voltage range 160 276V Norminal AC grid frequency 50 60Hz AC grid frequency range 45 55Hz 55 65Hz Rated output current 10 9A 13A 15 7A 18 3A Max...

Страница 34: ...tage 100V Min operating voltage 70V Nominal voltage 360V PV input operating voltage range 70 550V MPP voltage range at Full Power 180V 500V 190V 500V 230V 500V No of MPP trackers No of PV strings per...

Страница 35: ...y range 45 55Hz 55 65Hz Max efficiency 98 4 98 4 98 4 Euro eta 97 5 97 5 97 5 DC reverse polarity protection Integrated DC switch Integrated DC Surge protection class Insulation resistance monitoring...

Страница 36: ...t device of equivalent value according to model and age The warranty shall not cover transportation costs in connection with the return of defective modules The cost of the installation or reinstallat...

Отзывы: