2.1 Intended Use

The unit converts the DC current generated by the photovoltaic (PV) modules to 
grid-compliant  alternating  current  and  performs  single-phase  feed-in  into  the 
electricity  grid.  Growatt  2500MTL-S,Growatt  3000MTL- ,Growatt  3600MTL-

,Growatt  4200MTL- ,Growatt  5000MTL- ,Growatt  5500MTL- ,  inverters  are 

built according to all required safety rules. Nevertheless, improper use may cause 
lethal hazards for the operator or third parties, or may result in damage to the units 
and other property.

S

S

S

S

S

Principle of a PV plant with this GROWATT XXXXMTL-  single-phase inverter

S

Position

Description

A

PV modules

B

C

D

E

F

DC load circuit breaker

Growatt Inverter

AC load circuit breaker

Energy meter

Utility grid

The  inverter  may  only  be  operated  with  a  permanent  connection  to  the  public 
power grid. The inverter is not intended for mobile use. Any other or additional use 
is  not  considered  the  intended  use.  The  manufacturer/supplier  is  not  liable  for 
damage caused by such unintended use. Damage caused by such unintended use 
is at the sole risk of the operator.

2

 

Safety

PV modules Capacitive Discharge Currents

PV modules with large capacities relative to earth, such as thin-film PV modules 
with cells on a metallic substrate, may only be used if their coupling capacity does 
not exceed 470nF. During feed-in operation, a leakage current flows from the cells 
to  earth,  the  size  of  which  depends  on  the  manner  in  which  the  PV  modules  are 
installed  (e.g.  foil  on  metal  roof)  and  on  the  weather  (rain,  snow). This  "normal" 
leakage  current  may  not  exceed  50mA  due  to  the  fact  that  the  inverter  would 
otherwise  automatically  disconnect  from  the  electricity  grid  as  a  protective 
measure.

 

2.2 Qualification of skilled person

This grid-tied inverter system operates only when properly connected to the AC -
distribution  network.  Before  connecting  the  Growatt  MTL-   to  the  power 
distribution  grid,  contact  the  local  power  distribution  grid  company.  This 
connection  must  be  made  only  by  qualified  technical  personnel  to  connect,  and 
only  after  receiving  appropriate  approvals,  as  required  by  the  local  authority 
having jurisdiction.

S

2.3 Safety instruction

The GROWATT MTL-  Inverters is designed and tested according to international 
safety  requirements(IEC62109-1,VDE-AR-N4105,CE,VDE0126-1-1,CE10-21 
AS4777,NBT32004-2013,EN50438)

;

however, certain safety precautions must be 

observed  when  installing  and  operating  this  inverter.  Read  and  follow  all 
instructions, cautions and warnings in this installation manual. If questions arise, 
please contact Growatt's technical services at +86 (0)755 2747 1900.

S

2.4 Assembly Warnings

Prior to installation, inspect the unit to ensure absence of 
any  transport  or  handling  damage,  which  could  affect 
insulation  integrity  or  safety  clearances;  failure  to  do  so 
could result in safety hazards.

Assemble the inverter per the instructions in this manual. 
Use  care  when  choosing  installation  location  and  adhere 
to specified cooling requirements.

Unauthorized removal of necessary protections, improper 
use,  incorrect  installation  and  operation  may  lead  to 
serious  safety  and  shock  hazards  and/or  equipment 
damage.

In order to minimize the potential of a shock hazard due to 
hazardous voltages, cover the entire solar array with dark  
material prior to connecting the array to any equipment.

WARNING

Содержание Growatt 2500MTL-S

Страница 1: ...tt 5500MTL S Growatt 3600MTL S S S S Installation Operation Manual Shenzhen Growatt New Energy Technology CO LTD Building B Jiayu Industrial Park 28 GuangHui Road Shiyan Street Baoan District Shenzhen...

Страница 2: ...n Unpacking and inspection list 1 2 3 4 2 1 Intended Use 2 2 Qualification of skilled person 2 3 Safety instruction 2 4 Assembly Warnings 2 5 Electrical Connection Warnings 2 6 Operation Warnings 3 1...

Страница 3: ...shooting 10 6 1 Safety 6 2 Wiring AC Output 6 3 connecting the second protective conductor 6 4 Connecting the PV Array DCinput 6 5 Using shinetool to set the information of the inverter 6 6 Grounding...

Страница 4: ...nual GROWATT NEW ENERGY TECHNOLOGY CO LTD accepts no responsibilities to inform the users 1 4 1 Warnings in this document A warning describes a hazard to equipment or personnel It calls attention to a...

Страница 5: ...Power is an instantaneous value It displays the power your inverter is currently feeding into the power distribution grid Power rate is the radio of current power feeding into the power distribution...

Страница 6: ...due to the fact that the inverter would otherwise automatically disconnect from the electricity grid as a protective measure 2 2 Qualification of skilled person This grid tied inverter system operate...

Страница 7: ...n use the AC current gernerated as follows CAUTION Energy flows into the house grid The consumers connected for example household devices or lighting consume the energy The energy left over is fed int...

Страница 8: ...ight hand side of the enclosure IP 65 E DC Switch The DC switch of Growatt MTL S series is optional for different countries Information Growatt 2500MTL S 500V 10A 10A 70V 500V 230V 50HZ 2500VA 10 8A 0...

Страница 9: ...The storage temperature should be always between 25 and 60 And the storage relative humidity can achieve to 100 If there are a batch of inverters need to be stored the maximum layers for original cart...

Страница 10: ...tial damages to device and operators The installation location must be suitable for the inverter s weight and dimensions for a long period time Select the installation location so that the status disp...

Страница 11: ...expose the inverter to direct sunlight as this can cause excessive heating and thus power reduction Observe the Min clearances to walls other inverters or objects as shown in the diagram Be sure that...

Страница 12: ...location with some cover or protection There must be sufficient clearance between the individual inverters to ensure 5 3 Mounting the Inverter 5 3 1 Mounting the Inverter with bracket Using the mount...

Страница 13: ...ly firmly mounted on the wall after carefully checking WARNING Rise up the inverter a little higher than the bracket Considered the weight of them During the process please maintain the balance of the...

Страница 14: ...e single phase circuit breaker or other load disconnection unit for each inverter in order to ensure that the inverter can be safely disconnected under load NOTE The inverter is equipped with integrat...

Страница 15: ...h sign L N PE on the socket element and tighten the screws firmly Conductor cross section 5 2 mm 10AWG 6 6 mm 9AWG 6 3 connecting the second protective conductor Growatt 3600MTL S Growatt 4200MTL S Gr...

Страница 16: ...strings Same type Same quantity of PV modules connected in series String A String input Input 1 String input String B A B Input 2 Growatt MLT 10 MPPT 1 MPPT 2 If the inverter is not equipped with a D...

Страница 17: ...shinetool to set the information of the inverter About the software of shinetool and the usage of it please download from the web www ginverter com Download aspx 6 6 Grounding the inverter The inverte...

Страница 18: ...ackground light off After power on information displayed there will be another 4 interfaces displayed in turn if there is no knock signal input DANGER WARNING 6 7 2 DIP switch option corresponding to...

Страница 19: ...Auto Test State Update Software REMARK PV voltage low Initial waiting System checking System checking Connect to Grid Inverter watt at working System Fault Protection auto test 7 1 3 The Second line c...

Страница 20: ...Operate by knock 7 2 1 Knock type and definition The inverter can support three kinds of knock single knock double knock and thrice knock Each kind of knock has different function Refer to specified d...

Страница 21: ...cating with monitoring software or device the software or device may regard inverter s COM address as communication address Also may use inverter s serial number as communication address Before enteri...

Страница 22: ...u have to set PIN1 of the switch downward to OFF 2 When Exter wireless is selected you have to set PIN1 of the switch upward to ON 7 2 7 AC Error Record Checking When the LCD stays bright single knock...

Страница 23: ...please improve the heat dissipation condition Maybe you need to clean the heat sink 9 1 Checking Heat Dissipation 9 2 Cleaning the Inverter If the inverter is dirty turn off the AC breaker and DC swit...

Страница 24: ...isconnect the DC switch immediately Auto Test Failed Auto test didn t passed Contact power company By they decide whether to manually cancel 10 2 Errors E Errors E codes identify a possible equipment...

Страница 25: ...unscrew the bracket screws CAUTION 12 2 Packing the Inverter If possible always pack the inverter in its original carton and secure it with tension belts If it is no longer available you can also use...

Страница 26: ...input current per string of tracker A tracker B 10A 10A 10A 10A 10A 10A Protection devices DC reverse polarity protection yes yes DC switch ratiing for each MPPT yes yes Output Over current protection...

Страница 27: ...ion devices DC reverse polarity protection yes yes DC switch ratiing for each MPPT yes yes Output Over current protection yes yes Output Overvoltage Protection varistor yes yes Ground fault monitoring...

Страница 28: ...cm 49 50 Shipped to a Growatt service centre for repair or repaired on site or exchanged for a replacement device of equivalent value according to model and age The warranty shall not cover transport...

Страница 29: ...sonal access code if you need it please contact with GROWATT 15 2 Download Address www ginverter com Contact 16 If you have technical problems about our products contact the GROWATT Serviceline We nee...

Страница 30: ...y Knock to make the display bright knock to Enable Auto test double knock to enter Waiting to start the inverter will start auto test and wait for the test result When the inverter start auto test the...

Отзывы: