bootloader client is described below: 

1. Move the entire folder called "usb_bootloader_client_win" to the host machine. It is not necessary to 
install the bootloader client. 

2. The module must be powered and the miniB USB connector on the module main board must be 
accessible.  

3. Move the jumper block on pin 8 of the 8pin MTA-100 connector in the upper left corner of the main 
board so that pins 7 and 8 are connected. This enables the on-board programming mode. 

4. Power up the module. The LED D3 should light steadily to indicate the module is ready to 
communicate with the HID bootloader client. 

5. Open the bootloader client folder and find the file HIDBootloader. Double click this file to run it. 

6. Connect a USB type A cable from the host computer and plug the miniB end of the cable into the USB 
connector on the module. There may be some preliminary communication and installation of drivers. 
Eventually, a message should appear on the status window of the bootloader client indicating that a 
device has been detected and is ready to install files. The LED D3 on the module will flash periodically to 
indicate that it is ready. 

7. Click on the file menu tab and select Import Hex file option. 

8. When a file dialog window opens, navigate to the location of the module hex file to be loaded. 

9. Once the file is successfully imported, click on the Program tab and select the Erase, Program, Verify 
option.  

10. Status messages indicating the progress of the transfer should appear. 

11. Once the transfer is completed, power down the module. 

12. Move the jumper from pins 7 and 8 to pin 8. 

13. Power up the module and the new program version should start running. 

 

Содержание GMS-742a MIDI

Страница 1: ...Copyright 2022 Grove Audio LLC All rights reserved 1 GMS 742a MIDI to CV CONVERTER PRELIMINARY OPERATION MANUAL APRIL 17 2022 Grove Audio LLC Copyright 2022 All Rights Reserved...

Страница 2: ...hannel will produce the voltage equivalant of the MIDI velocity value one gate channel will produce a gate signal for the duration of the MIDI note on to note off time and one gate channel will produc...

Страница 3: ...Note CV Gate Ch 2 C2 C5 Note CV Gate Common MIDI Channel 10 2 Ch Independent Legato On Split Keyboard Ch 1 C0 B1 Note CV Gate Ch 2 C2 C5 Note CV Gate Common MIDI Channel 15 Channel Calibration Mode 1...

Страница 4: ...roximately two seconds until the Gate 1 LED starts to flash This indicates that the module is in the programming mode By briefly pressing the toggle switch to the right and releasing it the program gr...

Страница 5: ...ck div 6 Zero volts at C2 7 1 8 clock div default 7 Zero volts at C1 default Q104 mode 8 1 8 dotted clock div 8 Disable Pitchbend for mode 7 8 default 9 1 4 clock div 9 Enable Pitchbend for mode 7 8 1...

Страница 6: ...le switch to be high from the time the RUN realtime message or MIDI note command is received until the STOP realtime message or MIDI note command is received The output can be set to be either a level...

Страница 7: ...acy meter will work but a 5 digit DVM is preferred The current calibration points are between C3 and C5 The default values for these calibration points for the 5 Volt are 1 0000 Volts Calibration valu...

Страница 8: ...h external controller An external keyboard controller can be routed to the converter module to perform calibration by using MIDIOX Open the OPTIONS MIDI Devices tab Click the name of the converter mod...

Страница 9: ...ng calibration The module can store and recall up to 16 sets of calibration tables including zero and span calibration values for the 5 V 5V range The set of tables stored in the default location will...

Страница 10: ...Connect a USB type A cable from the host computer and plug the miniB end of the cable into the USB connector on the module There may be some preliminary communication and installation of drivers Even...

Отзывы: