© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Basic Installation/Operation
15
70421501 (EN)
Auxiliary Alarm
During tumble dryer installation, you have the option
to connect a separate alarm system to this auxiliary
output. Use of the auxiliary output is not required for
the fire suppression system to operate, but may be
used for additional protection.
NOTE: The auxiliary output is activated during
fire suppression system maintenance test sequence.
Consider this fact prior to your system test every
three months. (Example: If the external system
uses the auxiliary output to call the fire
department, inform the fire department before and
after the fire suppression system maintenance test.)
Gas Requirements
Natural Gas and Liquefied Petroleum
IMPORTANT: Any product revisions or
conversions must be made by the Manufacturer’s
Authorized Dealers, Distributors, or local service
personnel.
IMPORTANT: The tumble dryer must be isolated
from the gas supply piping system by closing its
individual manual shut-off valve during any
pressure testing of the gas supply piping system at
test pressure equal to or less than 3.45 kPa,
34.5 mbar (0.5 psi).
IMPORTANT: The tumble dryer and its manually
operated appliance gas valve must be disconnected
from the gas supply piping system during any
pressure testing of that system at test pressures in
excess of 3.45 kPa, 34.5 mbar (0.5 psi).
IMPORTANT: The installation must comply with
local codes.
NOTE: This manual is only a supplement. Refer to
installation/operation manual for full instructions.
European Gas
To reduce the risk of fire or explosion, DO
NOT CONNECT THE GAS LINE TO THE
TUMBLE DRYER IF THE GAS SERVICE IS
NOT THE SAME AS THAT SPECIFIED ON
THE TUMBLE DRYER SERIAL PLATE! It
will first be necessary to convert the gas
burner orifice and gas valve. Appropriate
conversion kits are available.
W060R1
WARNING
To reduce the risk of fire or explosion, if
the tumble dryer is to be connected to
Liquefied Petroleum (L.P.) gas, a vent to
the outdoors must be provided in the room
where the tumble dryer is installed.
W062R1
WARNING
WARNING
To reduce the risk of electric shock, fire,
explosion, serious injury or death:
• Disconnect electric power to the
tumbler before servicing.
• Close gas shut-off valve to gas tumbler
before servicing.
• Close steam valve to steam tumbler
before servicing.
• Never start the tumbler with any guards/
panels removed.
• Whenever ground wires are removed
during servicing, these ground wires
must be reconnected to ensure that the
tumbler is properly grounded.
W002
www.groupdynamics-laundry.com