background image

MCD-4800 Battery Replacement 

 

Ground Control

 

 

 

16.

 

Charge until termination is achieved (at least one of the following) 

a.

 

Cooling fan has turned off 

b.

 

“http://192.168.128.200/regs.htm” page shows “Batt Voltage” to be 
approximately 22.5 V with charger unplugged and unit powered on 
 

17.

 

Push down power button until latched 

a.

 

Blue LED in button should light 

b.

 

LCD screen on face plate should turn on and display scrolling text 

 

18.

 

Navigate to “http://192.168.128.200/protect/test.htm” in browser  

a.

 

User Name: admin 

b.

 

Password: gcmount 

 

19.

 

Click “New Full Battery” button and verify that LCD screen displays battery 
percentage is set to 100%. 

 

20.

 

Well done. You have successfully replaced the batteries and calibrated the 
battery level monitor in your MCD-4800. Thank you for choosing Ground Control 
Systems to provide this innovative satellite solution for your portable equipment 
and service needs. 
 

 

For additional technical support call (800) 931-5559 

 

 
 
 
 

 
 

Содержание MCD-4800

Страница 1: ...MCD 4800 Football Battery Replacement Instructions MCD 4800 Battery Replacement Ground Control Gen II 2017...

Страница 2: ...Avoid touching battery harness molex connector contacts during procedure Do not touch circuit board components unless wearing a properly grounded ESD wrist strap Parts Tools Needed Gen 2 MCD 4800 Batt...

Страница 3: ...MCD 4800 Battery Replacement Ground Control 2 Procedure 1 Unplug charger from MCD 4800 2 Open MCD 4800 lid and verify that power button is off unlit...

Страница 4: ...MCD 4800 Battery Replacement Ground Control 3 3 Remove eight screws that secure black top cover using a 9 64 s hex wrench set aside 4 Unscrew RP SMA antenna counterclockwise and set aside...

Страница 5: ...fully lift black top cover using raised placard on right hand side lean upright against case lid 6 Warning Do not touch battery connector contacts or exposed circuitry a Unplug battery connector b Uns...

Страница 6: ...MCD 4800 Battery Replacement Ground Control 5 7 Remove used battery pack and set aside 8 Remove three dome retention nuts shown above using 7 16 socket and ratchet wrench...

Страница 7: ...MCD 4800 Battery Replacement Ground Control 6 9 Lift dome upward from frame threaded studs until unseated 10 Unscrew coaxial connector counterclockwise from dome...

Страница 8: ...Control 7 11 Warning Do not touch battery connector contacts or exposed circuitry a Unplug battery connector b Unstrap top and bottom Velcro retention straps 12 Lift right edge of battery pack first a...

Страница 9: ...r MCD 4800 using replacement battery packs a Ground Control asks that you please dispose of your used battery packs at an appropriate battery disposal facility b Remember to label your replacement bat...

Страница 10: ...face plate should turn on and display scrolling text 18 Navigate to http 192 168 128 200 protect test htm in browser a User Name admin b Password gcmount 19 Click New Full Battery button and verify th...