Gröne K7 31 380 Скачать руководство пользователя страница 4

1

English

Application

Operation is possible in conjunction with:
• Pressurized storage heaters

Operation is 

not

 possible with:

• Low-pressure storage heaters (displacement water heaters)

Specifications

• Max. flow:

           6.6 L/min or 1.75 gpm/60 psi

• Flow pressure   

- min.                                       

7.25 psi

- recommended                         

14.5 - 72.5 psi

- greater than 72.5 psi, fit pressure reducing valve

• Max. operating pressure                      

145 psi

• Test pressure                                

232 psi

• Temperature    

- max. (hot water inlet)                      

176 

°

F

• Water connection:                                   cold - RH    hot - LH
• Deck thickness max.

2 3/8"

• Non reversible cartridge

Notes:

- Major pressure differences between cold and hot water 

supply should be avoided.

- To be installed according to local codes and regulations.
- This faucet is not intended for the use with portable 

appliances.

Installation

Flush piping system prior and after installation of faucet 
thoroughly! 

Mount sink faucet, 

see fold-out page III, Fig. [1].

Refer to the dimensional drawing on fold-out page I.

Note:

If brace (A) is omitted, deck thickness can be increased 
by 1 3/4" to a total of 2 3/8".

Connect sink faucet,

 see Figs. [1] and [2].

- Cold water connection (marked blue)

= right

- Hot water connection (marked red)

= left

Avoid cross connection. The cartridge is not reversible.

Connect the spray hose (B),

 see Fig. [1].

- Connect the handspray (C) without using any additional 

seals.

Open cold and hot-water supply and check connections 
for leakage!

Operation

1. Lever,

 see Fig. [3]. 

Slide lever to right

= open (water flow)

Slide lever to left

= closed

Slide lever towards front

= cold water

Slide lever towards back

= hot water

2. Handspray,

 see Fig. [4].

Slide lever to right (faucet open). The water will always emerge 
first from the aerator.

Diverter button:

Turning off the faucet automatically diverts the water flow from 
handspray to aerator.

Flow rate limiter

This faucet is fitted out with a flow rate limiter, permitting an 
infinitely individual variable reduction of the flow rate. The 
highest possible flow rate is set by the plant before despatch.

The use of flow rate limiters in combination with hydraulic 
instantaneous water heaters is not recommended.

To activate see “Replacing the cartridge” point 1 to 4, 
Figs. [5] and [6].

Maintenance

Inspect and clean all parts, replace as necessary and grease 
with special grease.

Shut off cold and hot water supply!
I. Replacing the cartridge,

 see fold-out page III, Fig. [5].

1. Lever out plug (D).
2. Loosen set screw (E).
3. Pull off lever (F).
4. Unscrew cap (G).
5. Turn out screwing (H).
6. Change the complete cartridge (J).

Assemble in reverse order.

Observe the correct installation position!

Make sure that the cartridge seals engage in the grooves and 
the locating pins at the base of the cartridge slot into the 
apertures on the housing. 
Screw in and tighten screwing (H).

II. Strainer and rose,

 see fold-out page III, Fig. [7].

1. Pull out ring (K) and unscrew rose (L) by using wrench (M).
2. Clean strainer (N) and rose (L).
3. With SpeedClean nozzles simply rub fingers over rose to 

remove limescale.
We guarantee that the SpeedClean nozzles will function 
unchanged for a period of five years.

Assemble in reverse order.

III. Check valve,

 see fold-out page III, Fig. [8].

1. Unscrew rinse spray (O) and remove check valve (P).
2. Pull off spring (R).
3. Unscrew shower hose (S) and remove check valve (T).

Assemble in reverse order.

Replacement parts,

 see fold-out page II ( * = special 

accessories).

Care

Instructions for care of this faucet will be found in the Limited 
Warranty supplement.

Press

 

Press

 

 = switches from spray to aerator flow

 = switches to spray flow

Отзывы: