This GROHE fitting can be used in conjunction with 
a pressurised storage heater or an instantaneous heater.

Operation with unpressurised storage heaters 
( = open water heaters) is not possible.

To ensure correct operation of the fitting, the flow 
pressure should be between 1 and 5 bar.

It is recommendable to install a pressure-reducing valve 
in the case of higher flow pressures.

In the case of new installations, flush the cold 
and hot water lines thoroughly until the water is 
completely free of contamination before and 
after installation. Otherwise any residues 
remaining in the lines may block the fitting and 
contaminate the drinking water.
Make sure that you do not damage the fitting 
surfaces with the tool during installation. For this 
reason, never use toothed pliers.

1

= Figure number

1

Installation on the worktop:

 Push O-ring 

A

 onto the 

fitting. Insert the fitting through the hole in worktop 

B

Fit sealing washer 

C

 and mounting set 

D

 from below. 

Fasten the fitting using nut 

E

.

2

Installation on the sink:

 Push O-ring 

A

 onto the 

fitting. Insert the fitting through the hole in sink 

F

. Fit 

support plate 

G

, sealing washer 

C

 and mounting 

set 

D

 from below. Fasten the fitting using nut 

E.

3

Ensure that you do not bend or twist the fitting 
pressure hoses.

4

Screw the fitting pressure hoses with the seal 

H

 to the 

service valves.

Open the cold and hot water supply and check 
the connections for watertightness.

5

Operate the fitting as shown.

This fitting is equipped with a flow rate limiter, permitting 
an infinitely variable individual reduction in flow rate.
The highest possible flow rate is set at the factory before 
despatch.

The use of flow rate limiters in combination with 
hydraulic instantaneous heaters is not 
recommended.

6

Lever out the plug 

I

. Remove the set screw 

J

 using 

a 3mm allen key and remove the lever 

K

. Remove the 

cap 

L

.

7

Change the flow rate by turning the adjusting screw 
using a 2.5mm allen key.

Fault:

 Flow rate noticeably reduced or changed spray 

pattern

1. Insufficient supply pressure: Check the upstream 

installation.

2. Mousseur (13 929) blocked/dirty: Clean or replace 

the mousseur.

Fault:

 Fitting housing leaking

1. Cartridge (46 824) screw coupling (46 815) loose: 

Tighten the cartridge screw coupling.

2. Seals at cartridge base damaged or dirt particles on 

sealing surfaces. Close the cold and hot water supply: 
Check and clean sealing surfaces, or replace 
cartridge completely.

3. Impermissible operating conditions, such as hot water 

temperature above 80 °C, pressure surges in 
upstream installation: Ensure that the operating 
conditions are in order. Replace cartridge completely 
if necessary.

Please contact your installer in the event of faults not 
described here.

For directions on care, please refer to the accompanying 
Care Instructions. Observe the valid national regulations 
when disposing of the fitting.

Prior to installation

Installation

, Page 2

Flow rate limitation

, Page 2

Troubleshooting

, Page 1

Care and recycling

GB

Содержание Wave Cosmopolitan 30 181

Страница 1: ... 16 HR 20 LT 24 Design Engineering GROHE Germany Wave Cosmopolitan Touch Cosmopolitan Get Cosmopolitan 99 696 231 ÄM 226656 03 14 Wave Cosmoplitan Touch Cosmoplitan Get Cosmopolitan F 3 I 7 CZ 11 HR 15 DK 19 LV 23 GB 4 NL 8 H 12 RO 16 N 20 LT 24 F 5 PL 9 P 13 TR 17 FIN 21 UA 25 E 6 GR 10 SLO 14 S 18 EST 22 RUS 26 30 181 30 182 30 204 ...

Страница 2: ...1 ...

Страница 3: ...2 3 max 80 C H 19mm 4 6 K J I L 3mm 2 5mm 7 5 B C D 13mm 1 E max 60mm A 19 017 G 2 13mm max 45mm F G C D E A 19 017 G ...

Страница 4: ...rds 5 Voici comment utiliser la robinetterie Cette robinetterie est équipée d un limiteur de débit Celui ci permet une limitation individualisée et en continu du débit Le débit maximal est préréglé en usine L utilisation du limiteur de débit est déconseillée avec des chauffe eau instantanés à commande hydraulique 6 Retirer le clapet I en faisant levier Dévisser la tige filetée J avec une clé Allen...

Страница 5: ...check the connections for watertightness 5 Operate the fitting as shown This fitting is equipped with a flow rate limiter permitting an infinitely variable individual reduction in flow rate The highest possible flow rate is set at the factory before despatch The use of flow rate limiters in combination with hydraulic instantaneous heaters is not recommended 6 Lever out the plug I Remove the set sc...

Страница 6: ...30 info grohe co jp KZ 7 727 311 07 39 info cac grohe com LT 372 6616354 grohe grohe ee LV 372 6616354 grohe grohe ee MAL 1 800 80 6570 info singapore grohe com N 47 22 072070 grohe grohe no NL 31 79 3680133 vragen nl grohe com NZ 09 373 4324 P 351 234 529620 commercial pt grohe com PL 48 22 5432640 bLuro grohe com pl RI 62 21 2358 4751 info singapore grohe com RO 40 21 2125050 info ro grohe com R...

Отзывы: