Grohe Veris 32 225 Скачать руководство пользователя страница 4

1

English

Applications

Operation is possible in conjunction with:
- Pressurized storage heaters
- Thermally controlled instantaneous heaters
- Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters (displacement 
water heaters) is 

not

 possible.

Specifications

• Max. flow:

- Spout approx. 25 L/min or 6.6 gpm/60 psi
- Handshower

             approx. 9.3 L/min or 2.5 gpm/60 psi

• Flow pressure

- min. 7.25 psi
- recommended 

14.5 - 72.5 psi

- greater than 72.5 psi, fit pressure reducing valve

• Max. operating pressure

145 psi

• Test pressure 

232 psi

• Temperature

- max. (hot water inlet)

176

°

F

Avoid major pressure differences between hot and cold water 
supply.

Note:

GROHE faucets with showers are equipped with non-return 
valves.

Installation

Refer to the dimensional drawings on fold-out page I.

I. Installing faucet

, see fold-out page II, Figs. [1] to [7].

1. Remove lid (A) of built-in mixer housing / back section and 

cut fitting template (B) to a height of 5/16" (8mm) Fig. [1].

2. Remove screw plugs (C), see Fig. [2].
3. Push rosette (D) and flange (E) onto pipe (F) and screw on 

sleeve (G), see Fig. [3].

4. Push back flange (E) and attach preassembled faucet to the 

built-in mixer housing / back section, see Fig. [4]. 

Ensure 

that the supply pipes (H) engage in the grooves of the 
built-in mixer housing / back section.

5. Align the faucet horizontally and vertically to the floor 

and fasten in place with washers (J) and screws (J1), 
see Fig. [5].

6. Seal joint around fitting template with permanently elastic 

compound, see Fig. [6].

Open hot and cold water supply and check connections 
for leakage.

7. Push rosette (D) against the floor.
8. Install swivel spout (K), see Fig. [7].

II. Installing hand shower

, see fold-out page II, Fig. [7].

1. Connect shower hose (L) to outlet nipple (M) on fitting.
2. Screw handshower (N) to shower hose (L).

Check faucet for correct operation

, see fold-out page II, 

Fig. [8].

Function of automatic diverter (O),

 see fold-out page II, 

Fig. [8].
Pulling the lever will release the water supply.
Water will emerge from the bath inlet first.

Pull diverter knob  = to divert flow from bath inlet to 

shower outlet

Press diverter knob = to divert flow from shower outlet to 

bath inlet

Flow is diverted automatically from shower outlet to bath inlet 
when the faucet is closed.

Flow rate limiter

This faucet is equipped with a flow rate limiter, permitting an 
infinitely variable individual reduction in flow rate. The highest 
possible flow rate is set at the factory before dispatch.

The use of flow rate limiters in combination with hydraulic 
instantaneous heaters is not recommended.

For activation, see “Replacing the cartridge”, points 1 
through 4, Figs. [9] and [10].

Maintenance

Inspect and clean all parts, replace as necessary and lubricate 
with special grease.

Shut off hot and cold water supply.

I. Replacing the cartridge

, see fold-out II, Fig. [10].

1. Remove cap (P).
2. Remove set (Q) and lever (R).
3. Remove cap (S).
4. Remove cap (T).
5. Remove screws (U) and detach complete cartridge (V).
6. Replace complete cartridge (V).

Assemble in reverse order.

Observe the correct installation position!

When installing the cartridge, ensure that the seals are 
correctly seated.

Fit screws (U) and tighten 

evenly and

 

alternately.

II. Non-return valve (08 565)

, see fold-out page I.

Assemble in reverse order.

III. Flow control (13 907)

, see fold-out page I.

Assemble in reverse order.

Replacement parts

,

 

see fold-out page I (* = special 

accessories).

Care

Instructions for care of this faucet will be found in the Limited 
Warranty supplement.

Отзывы: