background image

1

English

Application 

Operation is possible in conjunction with:
- Pressurized storage heaters
- Thermally controlled instantaneous heaters
- Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters
(displacement water heaters) is 

not

 possible.

Specifications 

Max. flow      

     5.7 L/min or 1.5 gpm/60 psi

Flow pressure   
- min.                                       

7.25 psi

- recommended                         

14.5 - 72.5 psi

- greater than 72.5 psi, fit pressure 
  reducing valve

Max. operating pressure                      

145 psi

Test pressure                                

232 psi

Temperature    
- max. (hot water inlet)                      

176 

°

F

Water connection                                    

hot - LH

         cold - RH

Non reversible cartridge

Note

Major pressure differences between hot and cold 
water supply should be avoided.

Installation

Flush piping system prior and after installation of 
faucet thoroughly!

Mount faucet on basin

Refer to the dimensional drawing on fold-out page I.

For installation, see fold-out page III,
figs. [1], [2] and [3].

Lift rod (A) must be inserted into the mixer body during 
installation.

Connect faucet

For this purpose the supply hoses must be connected 
to the angle stops (or other supply points), see figs. [1] 
and [2].

The hot water supply should be connected on the left, 
the cold water supply on the right side.

Avoid cross connection. The cartridge is not 
reversible.

Swivel spout,

 see fig. [3].

Fit pop-up drain (28 957),

 see fold-out page II, ensure 

that flange of pop-up drain is sealed.

Open angle stops and check faucet for correct 
function,

 see fig. [4].

Check connections for leakage.

Maintenance

Inspect and clean all parts, replace as necessary and 
grease with special grease.

Shut off the hot and cold water supply!

I. Replacing the cartridge 

(basin mixer), see fold-out 

page III, fig. [5].

1. Pull off cap (B).
2. Remove set (C) and pull off lever (D).
3. Pull off caps (E).
4. Turn out screwing (F) with key 27mm.
5. Change complete cartridge (G).

II. Replacing the cartridge 

(bidet mixer), see fold-out 

page III, fig. [6].

1. Pull off cap (B).
2. Remove set (C) and pull off lever (D).
3. Pull off decorative ring (H) and cap (I).
4. Turn out screwing (F) with key 27mm.
5. Change complete cartridge (G).

Assemble in reserve order.

Observe the correct installation position!

Make sure that the cartridge seals engage in the 
grooves and the locating pins at the base of the 
cartridge slot into the apertures on the housing.

Screw in and tighten screwing (F).

III. Flow regulator,

 see fold-out page II.

Unscrew and clean flow regulator (64 450/13 998).

Assemble in reverse order.

Replacement parts,

 see fold-out page II (* = special 

accessories).

Care

Instructions for care of this single lever faucet will be 
found in the Limited Warranty supplement.