1

English

Installation

    1. Remove the two screws (A1) from the fitting template (A), 

then remove the template, see fold-out page I, fig. [1].

    2. Turn the valve stem (B) clockwise to the 

OFF 

position.

    3. Make sure the water supply is turned on at the service 

stop valves (C). Stop valves must be in fully open position 
(slots horizontal) for valve to function.

    4. Push sleeve (D) onto the plastic guide (E) by gently de-

pressing the slotted section (E1) on the plastic guide. The 
slotted section (D1) of the sleeve must snap into the 
corresponding section (D2) of the guide, see fig. [2].

    5. The adjustable hot water limit stop (F) is factory set at 

neutral position to give maximum outlet temperature, see 
fig. [2] and [5].

Please refer to chapter 

"Maximum hot water limit 

setting"

 for limiting maximum outlet temperature.

    6. Slide the escutcheon (J) over the sleeve (D), see fig. [3].

    7. Tighten escutcheon with screws (J1).

Do not use excessive force to tighten the screws.

    8. Install adapter (G) onto the valve stem (B) by placing the 

stop post (G1) on top of the "Arrow" 

 (H) and tighten with 

screw (G2), see fig. [4].

    9. Position the scale handle (K) so that the 

OFF

 position 

lines up with the mark (D1) on the sleeve (D).

  10. Screw on handle sleeve (L)

  11. Connect the handle (M) or lever (N).

The pressure balancing valve is now ready for use.

If the pressure balancing valve is installed too deep, 

the 

fitting depth can be increased by 1" with an extension set, Part 
No. 47 344, see fold-out page II.

Maximum hot water limit setting

The adjustable hot water limit stop (F) is factory set in a neutral 
position (0), see fig. [5].

On applications requiring to limit the valve opening from full hot 
position, the factory set adjustable hot water limit stop must be 
reset as described below.

1. Remove the factory set adjustable hot water limit stop (F), 

see fig. [6].

2. Slide the adapter (G) onto the valve stem (B) by placing the  

stop post (G1) on top of "Arrow" 

 (H), see fig. [5] and fold-

out page III, fig. [7].

3. Turn the adapter (G) counterclockwise until the outlet water 

reaches the desired temperature and read the correspon-
ding number (1 to 10, see fig. [5]) against the stop post (G1).

4. Close the valve by turning the adapter (G) clockwise and 

remove the adapter (G).

5. Align the white mark (F1) on the limit stop (F) against the 

number (1 to 10, see fig. [5]) you have selected on the dial 
and slide the limit stop (F), see fig. [8].

6. Proceed to item 6 in chapter 

“Installation”

 to install the 

handle or lever.

Note:

The preset maximum temperature will change if the inlet 
temperatures change or the setting of the water heater 
thermostat is altered.

Winterizing the system

It is recommended that the 

"pressure balancing cartridge"

 

be removed from the valve casting if the system is to be shut 
off during the winter.

Maintenance

Check, clean and if necessary, replace parts.

Grease with special valve grease (Cat. No. 18 012).

Pressure balancing cartridge,

 see figs. [9] to [11].

    1. Unscrew handle (M) or lever (N), see fig. [9].

    2. Unscrew handle sleeve (L) and pull off scale handle (K).

    3. Loosen screw (G2) and remove adapter (G).

    4. Loosen screws (J1) and remove escutcheon (J).

    5. Shut off hot and cold water stops (C). The slots are 

vertical when the stops are in the off position, see fig. [10].

    6. Loosen screws (E2) and detach plastic guide (E) with 

sleeve, see fig. [11]. 

    7. Close the valve by turning the stem clockwise. Detach 

stop ring (O) and note position.

    8. Loosen the four corner screws (P1) and remove valve 

cover (P).

    9. Pull the pressure balancing cartridge (R) out of the valve 

body noting the location of 

"H"

 and 

"C"

 marking near the 

cartridge inlets.

  10. Remove the check valve inserts (R1).

If the check valves are removed it is important to reinstall 
them with the O-ring facing away from the cartridge. If 
they are installed incorrectly no water will flow.

The pressure balancing cartridge (R) must be replaced as a 
complete unit.

Reassemble in reverse order. Ensure that the hot 

"H"

 and 

cold 

"C"

 markings are on the correct side. 

Be sure that the stop ring (O) is installed in the position noted 
in step 7.

Replacement parts

, see fold-out page II (* = special 

accessories)

Care

Instructions for care of this faucet will be found in the Limited 
Warranty supplement.