This GROHE fitting can be used in conjunction with 
a pressurised storage heater or an instantaneous heater.

Operation with unpressurised storage heaters 
( = open water heaters) is not possible.

To ensure correct operation of the fitting, the flow 
pressure should be between 1 and 5 bar.

It is recommendable to install a pressure-reducing valve 
in the case of higher flow pressures.

In the case of new installations, flush the cold 
and hot water lines thoroughly until the water is 
completely free of contamination before and 
after installation. Otherwise any residues 
remaining in the lines may block the fitting and 
contaminate the drinking water.

Make sure that you do not damage the fitting 
surfaces with the tool during installation. For this 
reason, never use toothed pliers.

1

 - 

= Figure number

1

Apply sealing compound to the 1/2” threads of the 
S-unions. Use a suitable sealing compound for this 
purpose (available in specialist shops).

2

Screw the S-unions horizontally into the supply pipes 
at intervals of 150mm. You can increase the reach 
by 20mm with an extension see Replacement Parts, 
Pages 1 + 2 (07 130 = 20mm).

3

Fit the seals 

A

 in the union nuts and screw the fitting 

to the S-unions without the escutcheons 

B

.

-

Open the cold and hot water supply and check the 
connections for watertightness.

-

Close off the cold and hot water supply again and 
remove the fitting.

-

Screw the escutcheons 

B

 onto the S-unions against 

the wall and then screw the fitting back onto the 
S-unions.

Open the cold and hot water supply and check 
the connections for watertightness.

4

Operate the fitting as shown.

5

Operate the diverter as shown.

This fitting is equipped with a flow rate limiter, permitting 
an infinitely variable individual reduction in flow rate.

The highest possible flow rate is set at the factory before 
despatch.

The use of flow rate limiters in combination 
with hydraulic instantaneous heaters is not 
recommended.

6

Lever out the plug 

C

. Remove the set screw 

D

 using 

a 3mm allen key and remove the lever 

E

. Remove 

the cap 

G

.

7

Change the flow rate by turning the adjusting screw 
using a 2.5mm allen key.

Fault:

 Flow rate noticeably reduced or changed spray 

pattern
1. Insufficient supply pressure:

Check the upstream installation.

2. Mousseur (13 952) blocked/dirty:

Clean or replace the mousseur.

3. Non-return valve (08 565) blocked / dirty: 

Clean or replace the non-return valve.

Fault: 

Fitting housing leaking 

1. Cartridge (46 588) screws loose:

Tighten the cartridge screws alternately.

2. Seals at cartridge base damaged or dirt particles on 

sealing surfaces. Close the cold and hot water supply: 
Check and clean sealing surfaces, or replace 
cartridge completely.

3. Impermissible operating conditions, such as hot water 

temperature above 80 °C, pressure surges in 
upstream installation: 
Ensure that the operating conditions are in order. 
Replace cartridge completely if necessary.

Please contact your installer in the event of faults not 
described here.

For directions on care, please refer to the accompanying 
Care Instructions. Observe the valid national regulations 