Attention:
Please note the different installation depths of the products
carefully! The wall and ceiling materials, the furniture and the components
of the electrical supply must be carefully chosen to cope with 100% humidity.
Please integrate a vapour barrier into the design of the steam shower cabin
and a humidity resistant seal between the door and ceiling. Please do not use
a mosaic that has been glued to a mesh. The roof should have a gradient of 2%
running down to the back wall and the tiled stone seats should have a gradient
of 1-2% running down from back to front.
To avoid the risk of scalding do not use any metal materials for the seats and
storage spaces.
GROHE recommends the steam generator is installed in a separate room for
ease of maintenance, maximum safety and to comply with legal and regulatory
requirements. A free floor drain or pipe drain siphon for boiling water is also
needed next to the steam generator for flushing and decalcification.
To install only light and sound no separate space is needed, but it is important
to keep a minimal distance between the SPA Showers Base Unit Box (control unit)
and the shower (see VDE 0100 part 701 or EEC Norm). A locker (36 367 000) can
be used to coordinate all cables of the SPA Showers Base Unit Box.
The power supply should be installed higher than the steam generator and on the
opposite of the flushing pipe to avoid contact with water.
Do not direct the steam outlet at a wall, seating or any other object. There
should be a free space of at least 70 cm (28“) in front of the steam outlet.
Place the temperature sensor as far away from the steam outlet as possible.
Diagonally opposite is best.
Ensure that steam rooms that are used continuously for more than two hours
are ventilated by 10–20 cubic meters of air per person an hour. For detailed
information see the ‘Ventilation’ section of the Steam Generator TPIs (36 362 000
or 27 934 000).
To avoid damages to the building please ensure adequate ventilation
of the room above the ceiling shower and protect the surfaces with
an appropriate moisture resistant paint.
CAUTION!
Stay at least 12“ (30 cm) away from hot steam escaping from steam outlet.
INSTALLING A STEAM SHOWER
IMPORTANT DETAILS!
!
GROHE Digital Planning_FE_2016.indd 10
19.08.16 08:11
Содержание F10
Страница 1: ...GROHE F DIGITAL DELUXE PLANNING INSTALLATION GUIDE ...
Страница 3: ...grohe com Page 3 SHOWER CONFIGURATION XL 40 ...
Страница 5: ...grohe com Page 5 ...
Страница 6: ......
Страница 9: ...grohe com Page 9 ...
Страница 12: ......
Страница 13: ...GROHE F DIGITAL DELUXE grohe com Page 13 ...
Страница 20: ...PURE FLEXIBILITY SHOWER SOLUTIONS ...
Страница 21: ......
Страница 22: ...MEDIUM SHOWER CONFIGURATION LARGE SHOWER CONFIGURATION ...
Страница 25: ......
Страница 33: ......
Страница 41: ......