Grohe EUROSTYLE COSMOPOLITAN 23 300 Скачать руководство пользователя страница 7

9

GB

Application

Can be used in conjunction with: Pressurised storage heaters, 
thermally and hydraulically controlled instantaneous heaters. 
Operation with low-pressure displacement water heaters is 

not

 

possible.

Specifications:

  Flow pressure

- min.

0.5 bar

- recommended

1 - 5 bar

Operating pressure

max. 10 bar

Test pressure

16 bar

If static pressure is greater than 5 bar, fit pressure reducer.
Avoid major pressure differences between hot and cold water 
supply.

Temperature
Hot water inlet:

(maximum) 70 

°

C

Recommended:

       (energy saving) 60 

°

C

Scalding protection possible by fitting a temperature limiter (see 
replacement parts page 4, ref. No. 46 375).

Water connection

cold - low

 

Installation

Flush piping system prior and after installation of fitting 
thoroughly

 (Consider EN 806)

!

Install unions and screw-mount the mixer,

 see page 2.

Refer to the dimensional drawing on page 1.
The projection can be increased by 20mm with an extension, (see 
replacement parts page 4, ref. No. 07 130).
The cold water supply must be connected to the lower and the hot 
water supply on the upper inlet.

Adjustment of spout on mixer 23 301 und 23 302

There are 5 settings possible. 

Proceed as follows to change angle of spout:

1. Remove set screw (A) with 2.5mm key, see page 2.

2

2. Turn spout (B) into the wished postion, therefore refer to the 

dimensional drawings on page 1.

3. Refit spout (B) with set screw (A).

Open cold and hot-water supply and check connections for 
leakage!

Check fitting for correct operation

, see page 3.

Pulling the lever will release water delivery.
Water will emerge from the bath spout first.

Operation of automatic diverter (C), 

see page 3. 

Pull diverter button

= to divert flow from bath spout to
   shower outlet

Press diverter button

= to divert flow from shower outlet
   to bath spout

Flow is diverted automatically from shower outlet to bath spout 
when the mixer is turned off.

Flow rate limiter

This mixer is fitted with a flow rate limiter, permitting an infinitely 
individual variable reduction in the flow rate.
The highest possible flow rate is set by the factory before despatch. 
The use of flow rate limiters in combination with hydraulic 
instantaneous water heaters is not recommended.
For commissioning see “replacing the cartridge” page 3.

Maintenance

Inspect and clean all parts, replace as necessary and grease with 
special grease.

Shut off cold and hot water supply!

I. Replacing the cartridge

, see page 3.

1. Lever out plug (D).
2. Remove set screw (E) using a 3mm key and pull off

lever (G).

3. Pull off cap (H).
4. Replace complete cartridge (L).
5. Remove screws (K) and detach complete 

cartridge (L).

Assemble in reserve order.

Observe the correct installation position!

Make sure that the cartridge seals engage in the grooves on the 
housing. Fit screws (K) and tighten 

evenly and alternately

.

II. Non-return valve, 

see page 3.

Remove non-return valve (M).

Assemble in reserve order.

III. Diverter, 

see page 4.

1. Unscrew and remove diverter knob (N).

2. Remove diverter (O) using a 12mm key.

Assemble in reserve order.

IV. 

Unscrew and clean 

aerator (13 952)

, see page 4.

Assemble in reverse order.

Replacement parts,

 see page 4 ( * = special accessories).

Care

For directions on the care of this fitting, please refer to the 
accompanying Care Instructions.