background image

1

English

Application

Operation is possible in conjunction with:
- Pressurized storage heaters

Operation is 

not

 possible with:

- low-pressure storage heaters 

(displacement water heaters)

Specifications:

  Flow pressure

min. 7.25 psi

recommended 14.5 - 72.5 psi

Greater than 72.5 psi, fit pressure reducing valve

Operating pressure

max. 145 psi

Test pressure

232 psi

Max. flow      

     
             8.3 L/min or 2.2 gpm/60 psi

GROHE WaterCare

             5.7 L/min or 1.5 gpm/60 psi

Temperature
- Hot water inlet:

(maximum) 176 °F

-  Recommended:

122 °F* - 140 °F

- Handle rotation stop available (order No. 46 308)

Water connection

cold - RH 

hot - LH

Deck thickness max.

2  3/8"

Non reversible cartridge

Notes:

* Please follow all applicable local codes when setting the 

temperature on the hot water heater, as local municipalities 
may have codes limiting the maximum hot water heater 
setting to 122 °F.

- Major pressure differences between hot and cold water 

supply should be avoided.

- To be installed according to local codes and regulations.
- This faucet is not intended for the use with portable 

appliances.

Installation

Flush pipes thoroughly!

Prepare sink faucet

Refer to the dimensional drawing on fold-out page I.

Mount sink faucet

1. Fit swivel spout. Swivel range can be adjusted by means of 

stop (A), see fold-out page III, fig. [1].

2. Fit O-Ring (B) and insert faucet into sink, see fig. [2].
3. Fit brace (C), if necessary, with seal (D), washer (E) and 

connect nut (F).

Note:

If brace (C) is omitted, deck thickness can be increased 
by 9/16" to a total of 2 3/8".

Mount handspray

1. Insert spray holder (G) through the hole, aligning the 

seal (G1) with the groove on the flange, see fig. [2].

2. Tighten spray holder (G) with mounting set (H).
3. Loosely screw handspray (I) with seal (I1) onto spray 

hose (J).

4. Insert spray hose (J) complete with handspray (I) through 

the spray holder (G) from above.

5. Connect spray hose (J) to swivel connection (K) of the spout 

body.

6. Tighten spray hose (J) with handspray (I) facing to front.

Connect sink faucet,

 see figs. [2] and [3].

Open hot and cold-water supply and check connections 
for leakage!

Check fitting for correct operation,

 see fig. [4].

Flow rate limiter

This mixer is fitted with a flow rate limiter, permitting an 
infinitely individual variable reduction in the flow rate. The 
highest possible flow rate is set by the factory before despatch.

The use of flow rate limiters in combination with hydraulic 
instantaneous water heaters is not recommended.

For commissioning see “replacing the cartridge”  
point 1 to 3, fig. [5] and [6].

Maintenance

Inspect and clean all parts, replace as necessary and grease 
with special grease.

Shut off hot and cold water supply!

I. Replacing the cartridge,

 see fig. [5].

1. Lever out plug (L).
2. Remove set screw (M) using a 3mm socket spanner and 

pull off lever (N).

3. Unscrew cap (O).
4. Remove screws (P) and detach complete cartridge (R).
5. Replace complete cartridge (R).

Assemble in reverse order.

Observe the correct installation position!

Make sure that the cartridge seals engage in the grooves on 
the housing. Fit screws (P) and tighten 

evenly and 

alternately

.

II. Check valve, 

see fig. [5].

1. Proceed as for replacing the cartridge, points 1 to 4. 
2. Pull off and replace check valve (S).

III. Diverter, 

see fig. [7].

1. Proceed as for replacing the cartridge, points 1 to 4. 
2. Loosen screw in the housing as shown in fig. [7].
3. Pull off swivel spout (T).
4. Pull out the diverter (U).
5. If necessary change seal (V).

IV.

Unscrew and clean 

flow control (13 954)

, see fold-out 

page II.

Assemble in reverse order.

Replacement parts,

 see fold-out page II ( * = special 

accessories).

Care

Instructions for care of this faucet will be found in the Limited 
Warranty supplement.