Grohe Eurosmart 32 644 Скачать руководство пользователя страница 4

1

USA

Application 

Operation is possible in conjunction with:
• Pressurized storage heaters
• Thermally controlled instantaneous heaters
• Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters (displacement 
water heaters) is 

not

 possible.

Specifications 

• Max. flow

  

- Spout

approx. 24 l/min or 6.3 gpm

- Handshower

max. 9.5 l/min or 2.5 gpm

• Flow pressure 

- min.

7.25  psi

- recommended

14.5 - 72.5 psi

- greater than 72.5 psi, fit with pressure reducing valves

• Max. operating pressure

145 psi

• Test pressure

232 psi

• Temperature 

- max. (hot water inlet)

176 

°

F

- Scalding protection possible by fitting a handle rotation 

stop (see replacement parts fold-out page I, order 
no. 46 308).

• Water connection

cold - Right hand

hot - Left hand

Notes

• Installation of backflow protection must comply with local 

codes and regulations.

• An access panel must be provided for access to diverting 

unit and hose connections.

• Major pressure differences between cold and hot water 

supply should be avoided.

Installation

Layout dimensions to establish centers and proper clearences, 
see dimensional drawing on fold-out page I.

Flush pipes thoroughly!

Installing faucet body

- Fit faucet body (A) with mounting set (A1), see fold-out 

page II, fig. [1].

Installing spout, 

see figs. [1] and [2].

1. Fit shank (B) with mounting set (B1), see fig. [1].
2. Fit spout (C) to the shank (B), tighten set screw (D)

with 4mm allen wrench and screw on cover cap (E), 
see fig. [2].

3. Screw diversion part (F) on shank (B).

Installing hose guide and hand shower, 

see figs. [3] and [4].

1. Unscrew guide (G) and remove escutcheon (H), see fig. [3].
2. Fit hose guide (I) with mounting set (I1).
3. Fit escutcheon (H) and screw on guide (G).
4. Screw coupling piece (J) onto shower hose (K), see fig. [4]. 
5. Screw handshower (L) to coupling piece (J).

Connecting the faucet, 

see figs. [5] and [6].

The hot water supply should be connected on the left, the cold 
water supply on the right side.

Open cold and hot water supply and check connections 
for leakage.

Operation

a) Lever

Pull lever

= open (water flow)

Press lever down

= closed

Turn lever right

= cold water

Turn lever left

= hot water

b) Diverter 

Pulling the lever will release water supply.
Water will emerge from the bath spout first.
Pull diverter knob

= to divert flow from bath spout to 

shower outlet

Press diverter knob

= to divert flow from shower outlet to 

bath spout

Flow is diverted automatically from shower outlet to bath spout 
when the mixer is turned off.

Maintenance

Inspect and clean all parts, replace as necessary and grease 
with special grease.

Shut off cold and hot water supply!

I. Replacing the cartridge, 

see fig. [7].

1. Lever out plug (M).
2. Loosen set screw (N) with 3mm allen wrench and pull off 

lever (O).

3. Unscrew cap (P).
4. Remove screws (R).
5. Replace complete cartridge (S).

Assemble in reverse order.

Observe the correct installation position.

Make sure that the cartridge seals engage in the grooves on 
the housing. Fit screws (R) and tighten 

evenly and 

alternately

.

II. Diverter, 

see fig. [8].

1. Pull off cover cap (T).
2. Screw out screw (U) and detach diverter knob (V).
3. Unscrew diverter (W) by using a 17mm socket wrench.

III. Shower hose, 

see fig. [9].

1. Pull out shower hose (K) and unscrew handshower (L) from 

coupling piece (J).

2. Unscrew guide (G) with integrated shower seal.

IV. 

Unscrew and clean 

flow control (13 907), 

see fold-out 

page I.

Assemble in reverse order.

Replacement parts,

 see fold-out page I ( * = special 

accessories).

Care

Instructions for care of this faucet will be found in the Limited 
Warranty supplement.

Отзывы: