Safety notes

Prevent danger resulting from damaged voltage 
supply cables. 
If damaged, the voltage supply cable must be replaced 
by the manufacturer or his customer service 
department or an equally qualified person.

• Installation is only possible in frost-free rooms.

• The plug-in voltage supply is only suitable for indoor use.

• The plug-in connectors must 

not

 be directly or indirectly 

sprayed with water when cleaning.

• The voltage supply must be separately switchable.

• Use 

only genuine replacement parts and accessories

The use of other parts will result in voiding of the warranty 
and the CE identification, and could lead to injuries.

Technical data 

Fitting with switched-mode power supply:

• Voltage supply:

100-240 V AC 50-60 Hz/6.75 V DC

• Power consumption:

2.4 W

Fitting with battery:

• Voltage supply:

6V lithium battery type CR-P2

• Automatic safety shut-off:

60 s

(6 - 420 s adjustable)

• Run-on time:

1 s

(0 - 19 s adjustable)

• Reception range according to Kodak Gray Card, 

grey side, 8x10", landscape (7 - 20cm adjustable):

12cm

• Type of fitting protection:

IP 59K

Electrical test data

• Software class

A

• Contamination class

2

• Rated surge voltage

2500 V

• Temperature of ball impact test

100 °C

The test for electromagnetic compatibility (interference 
emission test) was performed at the rated voltage and rated 
current.

If static pressures exceed 0.5 MPa, a pressure-reducing valve 
must be installed.

Installation

, see fold-out page I - II.

Flush pipes thoroughly before and after 
installation 

(observe EN 806)

!

Open hot and cold water supply and check that 
connections are watertight.

Functions, programme selection,

see technical product information,

www.grohe.com/tpi/euroeco-ce

GROHE Deutschland Vertriebs GmbH 

Zur Porta 9

D-32457 Porta Westfalica

Maintenance

, see fold-out page II.

• Shut off water supply. 

• Disconnect voltage supply.

• Inspect and clean all components and replace if
  necessary.

Batteries which are almost discharged are displayed 
by a flashing indicator lamp in the sensor system.

Replacement parts

see fold-out page I (* = special accessories)

,

Care

For directions on the care of this fitting, please refer to the 
accompanying Care Instructions.

Fault / Cause / Remedy

Fault

Cause

Remedy

Water not flowing

• Filter upstream of solenoid valve blocked

• Solenoid valve defective

• Plug-in connector without contact

• No voltage

- Battery discharged
(indicator lamp lights up continuously)

- Power supply unit defective

- Clean or replace filter

- Replace solenoid valve

- Check plug-in connector

- Replace battery

- Replace power supply unit

Undesired water 
flow

• Sensor system detection zone set too high 

for local conditions

• Automatic flushing activated

• Solenoid valve defective

- Reduce range using remote control (special 

accessory, prod. no.: 36 407)

- Wait 1 - 10 minutes

- Replace solenoid valve 

Flow rate too low

• Mousseur dirty 

• Filter in solenoid valve dirty

- Clean or replace mousseur

- Clean or replace filter