Technical data
Fitting with switched-mode power supply:
• Voltage supply:
100-240 V AC 50-60 Hz/6.75 V DC
• Power consumption:
2.4 W
Fitting with battery:
• Voltage supply:
6V lithium battery type CR-P2
Bluetooth
®
:
• Power consumption:
1 W
• Output:
Bluetooth
®
- Class 2
•
Bluetooth
®
- version:
4.0
•
Bluetooth
® -
Transmission distance:
about 10m
(depending on the environments)
• Automatic safety shut-off:
60 s
(6 - 420 s adjustable)
• Run-on time (0 - 19 s adjustable):
1 s
• Reception range according to Novoflex Zebra XL Grey Card,
grey side, 8x10", landscape (7 - 20cm adjustable):
12cm
• Type of fitting protection:
IP 59
Thermal disinfection possible.
Electrical test data
• Software class
A
• Contamination class
2
• Rated surge voltage
2500 V
• Temperature of ball impact test
100 °C
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Installation
, see fold-out page I - II.
Flush pipes thoroughly before and after
installation
(observe EN 806)
!
Open hot and cold water supply and check that
connections are watertight.
Operation and settings,
see technical product information, 99.0409.xxx /
99.0438.xxx
Activating setting mode
Disconnect the power supply to the electronics and reconnect
after 10 s.
The indicator lamp in the sensor system illuminates in setting
mode when the detection zone of the fitting is reached by an
approaching user.
Setting mode is automatically terminated after 3 minutes..
Maintenance
, see fold-out page II.
•Shut off water supply.
•Disconnect voltage supply.
•Inspect and clean all components and replace if
necessary.
Batteries which are almost discharged are displayed
by a flashing indicator lamp in the sensor system.
Replacement parts
see fold-out page I (* = special accessories)
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Fault / Cause / Remedy
Fault
Cause
Remedy
Water not flowing
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
- Battery discharged
(indicator lamp lights up continuously)
- Power supply unit defective
- Clean or replace filter
- Replace solenoid valve
- Check plug-in connector
- Replace battery
- Replace power supply unit
Undesired water
flow
• Sensor system detection zone set too high
for local conditions
• Automatic flushing activated
• Solenoid valve defective
- Reduce range using remote control (special
accessory, prod. no.: 36 407) / app
- Wait 1 - 10 minutes
- Replace solenoid valve
Flow rate too low
• Mousseur dirty
• Filter upstream of solenoid valve dirty
- Clean or replace mousseur
- Clean filter
Automatic flush
does not work
• Safety shutdown active
• Ambient conditions not suitable
- Remove object
- Check ambient conditions with remote control
(special accessory, order no.: 36 407) in test
mode at maximum range, LED must not light up.
b9904081.book Seite 3 Dienstag, 8. November 2022 9:24 09
Содержание EUROECO CE 36271000
Страница 22: ...19 b9904081 book Seite 19 Dienstag 8 November 2022 9 24 09 ...
Страница 48: ...45 s t 36 407 1 10 36 407 Bluetooth b9904081 book Seite 45 Dienstag 8 November 2022 9 24 09 ...
Страница 50: ...47 36 407 1 10 36 407 Bluetooth b9904081 book Seite 47 Dienstag 8 November 2022 9 24 09 ...
Страница 51: ...b9904081 book Seite 1 Dienstag 8 November 2022 9 24 09 ...
Страница 52: ...b9904081 book Seite 1 Dienstag 8 November 2022 9 24 09 ...
Страница 53: ...b9904081 book Seite 1 Dienstag 8 November 2022 9 24 09 ...
Страница 54: ...b9904081 book Seite 1 Dienstag 8 November 2022 9 24 09 ...