background image

2

1. Functional characteristics

The infra-red-electronic system emits invisible pulsed light. This light is reflected off a user for a minimum
of 10 s (minimum delay time) and is then received again by the electronic system, the solenoid valve is 
actuated approx. 1 second afer the user steps away. The solenoid valve opens and the urinal bowl is 
flushed.
The range of sensitivity is dependent on the reflective properties of the objekt.

2. Setting mode

In the setting mode, the flow volume can be changed (see flow volume setting) and the system’s detection
zone can be checked. The 10 s minimum delay time is not available in the setting mode.
The setting mode is activated as follows:
- Disconnect the power supply to the electronic module.
- Wait 5 s
- Reconnect the power supply to the electronic module.
The LED in the infra-red window illuminates (on) when the system’s detection zone is reached as result of the
system being approached. It is possible also to adjust the detection zone via the optional remote control.
The system automatically switches to operating mode 3 minutes after the power supply has been installed.
The functions described above are no longer available.

3. Flow volume setting

The factory set flow volume is approx. 3 litres at 3 bar flow pressure.
The flow volume can be changed if it is necessary to make an adjustment to the factory settings (figs. 13 - 21)

Procedure for flow volume setting

Fig. 13 - 15: Disconnect the power supply to the electronic module and wait 5 s before reconnecting it.
Fig. 16:

Hold hand at distance of approx. 5 - 10 cm in front of the sensor window (LED flashes quickly).

Fig. 17:

The indicator lamp automatically goes out after approx. 5 s.

Fig. 18:

Remove hand from the detection zone (at least 60 cm).

Fig. 19:

Hold hand in front of the sensor window again at a distance of 5 - 10 cm.
LED starts to flash:
2 flashes (approx. 2 litres)
Pause
3 flashes (approx. 3litres = factory setting)
Pause
etc. until
7 flashes (approx. 7litres)

Fig. 20:

Remove hand after a flashing sequence (desired flow volume). The system then flushes
with the set flow volume afterwards. The selected flow volume is indicated via the number
of LED flashes.

Fig. 21:

Check the flow volume. If the flow volume is ok 

J

 wait > 20 s (the system automatically

switches 
to normal operating mode).
If not 

L

: Set the flow volume again.

4. Infra-red remote control 36206 (special equipment)

1.) Setting the range of reception
2.) Setting the flush duration
3.) Open solenoid valve
4.) Close solenoid valve (permanent stop)
5.) Resetting the basic setting
6.) Test mode
7.) 24-hours flush (On/Off)

GB

t5833.book  Seite 2  Mittwoch, 14. August 2002  12:17 12

Отзывы: