background image

F211955R00

3

Grease recommendations

Grease should not contain graphite or PTFE. The use of correct grease in the
TriPlus system is of utmost importance. The use of grease with a maximum of
5% molybdenum disulphide (MoS2) is permitted.
Groeneveld recommends the use of its GreenLube grease.
Consult your local Groeneveld dealer prior to change of grease (specifications)
or any other inquiries you may have.

Regularly checks of the greasing system

Check the following points of the TriPlus greasing system:
1.

The grease level in the reservoir of the pump unit (refill on time);

2.

The pump unit for damage and leakage;

3.

The operation of the whole greasing system. Perform a cycle test for 
every grease outlet of the pump unit. Retrieve the fault codes stored in the 
control unit, either by using the test push-button on the pump unit or by 
connecting a UniGINA to the control unit;

4.

The primary and secondary grease lines for damage and leakage;

5.

The grease points, collar of fresh grease should be present at all grease 
points.

Filling the grease reservoir

The grease pump must be suitable for class 2 grease.
First fill the filling hose with grease (if the filling pump or grease barrel is new).
This prevents air being introduced in the grease reservoir.
1.

Remove the dust cap of the filler coupling.

2.

Clean the filler coupling and the coupling on the hose thoroughly.

3.

Lock the hose onto the filler coupling or position the grease gun onto the 
filler coupling.

4.

Fill the reservoir up to its maximum level, as indicated on the reservoir. 
Never fill the reservoir any higher than the maximum level indicated, oth-
erwise the follower plate may become damaged.

5.

Remove the filling hose.

6.

Clean the dust cap and filling coupling with a clean rag. Place the dust cap 
back onto the filler coupling.

NOTES
If the pumping action seems to go heavy, check the filter behind the filling
coupling on the pump unit. Clean the filter and the filler coupling. Also
check the filling hose for obstructions and clean it.
Any air that may be introduced beneath the follower plate will escape
through an opening at the top of the guide rod of the follower plate. These
air inclusions, together with any excess grease, will exit via the de-
aerating opening at the side on the pump unit.

USER

’S

 INSTRUCTION

Содержание TriPlus Truck-3

Страница 1: ...1 TriPlus Truck 3 and Trailer 3 2 F211955R00 Your efficiency is our Challenge EN User s Instruction...

Страница 2: ...the pump unit has three functions Performing a cycle test via one of the grease outlet s of the pump unit Retrieving error messages stored in the memory of the control unit Lamp reset after solving t...

Страница 3: ...e reservoir The grease pump must be suitable for class 2 grease First fill the filling hose with grease if the filling pump or grease barrel is new This prevents air being introduced in the grease res...

Страница 4: ...pressing the test push button once A cycle test is being per formed via grease outlet 1 Repeatedly 2 x 0 3 se conds on followed by a pause of 2 seconds After momentarily pressing the test push button...

Страница 5: ...d 13 Outlet 2 blocked 14 Outlet 3 blocked 15 Empty reservoir See Filling the grease reservoir on page 3 16 Low level See Filling the grease reservoir on page 3 21 Revolution fault 22 Open load pump mo...

Страница 6: ...ns with the automatic greasing system please contact your Groeneveld dealer as soon as possible 55 Open load block switch C 61 High temperature PCB exceeded 62 Low temperature PCB exceeded Error code...

Страница 7: ......

Страница 8: ...eneveld Transport Efficiency B V Stephensonweg 12 4207 HB Gorinchem P O Box 777 4200 AT Gorinchem The Netherlands Ph 31 183 641 400 F 31 183 624 474 http www groeneveld group com www groeneveld group...

Отзывы: