Groeneveld MSFi Скачать руководство пользователя страница 16

MSFI 

-

 F801306

 

16

 

 

Accessories and Components

 

Ø

4mm Elbow Fittings 

 

 

Ø4mm Straight Fittings 

 

 

Ø

4mm 

-

 Unions

 

Part No.

 

Thread Size

 

 

Part No.

 

Thread Size

 

 

Part No.

 

Type

 

PM90412 

 

1/8NPT

 

 

PM80412 

 

1/8NPT

 

 

38497L1

 

Elbow Stem

 

PM90484 

 

1/4

-

28UNF

 

 

PM80484 

 

1/4

-

28UNF

 

 

38497T1

 

T

-

Union 

 

PM90485 

 

5/16

-

24UNF

 

 

PM80485 

 

5/16

-

24UNF

 

 

38497Y2

 

Y

-

Union

 

PM90487 

 

1/8BSPT

 

 

PM80487 

 

1/8BSPT

 

 

LE 505

-

PCM

 

Union

 

PM90489 

 

M6x1

 

 

PM80489 

 

M6x1

 

 

LE 60525

-

PC

 

Bulkhead (C)

 

PM90490 

 

M8x1

 

 

PM80490 

 

M8x1

 

 

25487

-

072

 

Bulkhead (M)

 

PM90492 

 

M10x1

 

 

PM80492 

 

M10x 1

 

 

 

 

38497S1

 

1/8NPT Swivel

 

 

LE 80512

-

PL

 

1/8NPT

 

 

 

 

38497S2 

 

1/4

-

28UNF Swivel

   

 

 

 

 

 

Brushes and Fittings 

 

Ø4mm Tubing

 

 

Part No.

 

Description

 

Part No.

 

Description

 

A400

 

Oil Brush 

-

 Ø3/4

” 

-

 

G1/4

 

MSF

-

T

-

4N50E

 

Ø4mm Nylon Tubing Un

-

Primed (15m/50ft)

 

A410

 

Oil Brush 

-

 L1.6

” 

x W1.2

” 

-

 

G1/4

 

152057

-

164

 

Ø4mm Nylon Tubing Un

-

Primed (50m/164ft)

 

A411

 

Oil Brush 

-

 L2.4

” 

x W1.2

” 

-

 

G1/4

 

MSF

-

T

-

4N50G

 

Ø4mm Nylon Tubing Primed 

-

 Grease (15m/50ft)

 

A412

 

Oil Brush 

-

 L3.9

” 

x W1.2

” 

-

 

G1/4 

 

152823

-

164

 

Ø4mm Nylon Tubing Primed 

-

 Grease (50m/164ft)

 

0441366

 

Ø4mm x G1/4 Straight

 

MSF

-

T

-

4N50F

 

Ø4mm Nylon Tubing Primed 

-

 Food (15m/50ft)

 

0442050

 

Ø4mm x G1/4 Swivel Elbow

 

152823

-

164FG

 

Ø4mm Nylon Tubing Primed 

-

 Food (50m/164ft)

 

38497Y4

 

Ø4mm 4

-

Way Inlet x G1/4 

 

 

 

Contact Groeneveld

-

BEKA for quotation.

 

Line Protection

 

 

Line Labels

 

Part No.

 

Description (ft)

 

Part No.

 

Description

 

20030

 

1/4” 

Spiral Wrap (Single tube)

 

39257

-

A1

 

For up to 12 point system

 

20034

 

3/8” 

Spiral Wrap (2

-

4 tubes)

 

39257

-

A2

 

For up to 24 point system

 

20031

 

1/2” 

Spiral Wrap (5

-

12 tubes)

 

39257

-

A3

 

For up to 36 point system

 

20035

 

1” 

Spiral Wrap (13

-

35 tubes)

 

 

39694A250

 

1/4” 

Split Convolute (Single tube)

 

39694A375

 

3/8” 

Spit Convolute (2

-

4 tubes)

 

39694A500

 

1/2” 

Split Convolute (5

-

7 tubes)

 

39694A625

 

5/8” 

Split Convolute (13

-

19 tubes)

 

Содержание MSFi

Страница 1: ...e the accuracy of the information contained in this catalog but no liability is accepted for errors omissions or for any other reason Applicable Pumps AC15XXL 2 A AC25XXL 2 A AX13XXL A AX23XXL A Appli...

Страница 2: ...cludes but is not limited to Protective eyewear Respirators protective clothing and gloves as recommended by the Lubricant manufacturer PLASTIC PART CLEANING SOLVENT HAZARD Many solvents can damage pl...

Страница 3: ...ty Directive 2006 42 EC Machinery Directive 2011 65 EC Restriction of Certain Hazardous Substances Has been designed and manufactured to the following specifications BS EN 61000 6 2 2005 BS EN 61000 6...

Страница 4: ...ancillary equipment Using the pump mounted adhesive template part number 31867 900 supplied position and drill the bracket holes mounting positions and bracket clearances detailed as per the above ima...

Страница 5: ...ng from the furthest point from the pump feed the lubrication lines through the machine following existing machine services where possible Ensure that the lubrication lines are positioned to fit the b...

Страница 6: ...e images 3 and 4 below A choice of fittings are available to suit all requirements see page 16 Accessories 1 2 3 4 The MSFi systems are suitable for use with most bearing types Brushes are available f...

Страница 7: ...h red or be continuously lit red depending on the current programming setting The red illumination or flashing of the LED indicates that the pump is in the programming mode and is showing the current...

Страница 8: ...is a continuous power supply to the circuit and pump The indicator light will flash green when the motor is in operation and is lit red when in the programming mode Pressing the manual override butto...

Страница 9: ...ake sure to retain the O ring 5 Access PCB D and adjust dip switch as required see PCB 83344 426 image at the bottom of this page for the location of the dip switch 6 Re assemble ensuring the drive ad...

Страница 10: ...switched on and after the allotted dwell time of the already pro grammed pump has elapsed The pump will run for 6 minutes and dwell for the allotted time as programmed 6 minutes dwell if 6 minute pro...

Страница 11: ...e A VDC Pump R1 calibrated with 2 Red P E O1 4 Yellow P E O3 6 Grey P E O5 programmed for a 15 minute cycle time 2x0 01 4x0 025 6x0 06 0 48cc 1250cc 0 48cc 2604 16 Revs 2604 16 x 15 39017 4 minutes un...

Страница 12: ...pumping elements set at the 3 setting All other pumping elements sold separately 12 24 VDC Pump Output Combinations Pump Element Timer Setting Delay Cycle 0 1 8rpm 1 6min 2 9min 3 12min 4 27min 5 42m...

Страница 13: ...ll variants come with externally programmable blink code timer continuous 6 9 12 27 42 and 57min delay options All variants come with 5ft pump wire male AMP Superseal and a matching 30ft wire harness...

Страница 14: ...EMBLY PADDLE ASSEMBLY WITH DRIVE ADAPTER 2L 1 7 32814 624 32814 763 32814 764 CAMSHAFT ASSEMBLY 12 PORT CAMSHAFT ASSEMBLY 24 PORT CAMSHAFT ASSEMBLY 36 PORT 1 8 32478 312 32478 328 32478 336 MANIFOLD R...

Страница 15: ...MSFI F801306 15 Note Wiring connection may differ from that shown 1 3 4 5 6b 7 8 9 10 12 2 11 6a 6c Exploded View...

Страница 16: ...152057 164 4mm Nylon Tubing Un Primed 50m 164ft A411 Oil Brush L2 4 x W1 2 G1 4 MSF T 4N50G 4mm Nylon Tubing Primed Grease 15m 50ft A412 Oil Brush L3 9 x W1 2 G1 4 152823 164 4mm Nylon Tubing Primed...

Страница 17: ...ork a Refer to Problem A b Dwell time is too long or b Reduce the system dwell time c Lubrication quantity is too little c Change the pumping element with an increased output d System is blocked d Ref...

Страница 18: ...Solution A Pump does not work a No input power a Check for power to the pump and controller b Fuse is blown b Check in line fuse replace if necessary c Loose broken wire connection inside the pump c C...

Страница 19: ...____________________ ___________________________________ ___________________________________ ___________________________________ ___________________________________ ___________________________________...

Страница 20: ......

Отзывы: