IMPORTANT — READ FIRST — IMPORTANT

THESE  APPLIANCES  MUST  BE  INSTALLED BY A COMPETENT PERSON IN CONFORMITY WITH THE
INSTALLATION AND SERVICING INSTRUCTIONS AND NATIONAL REGULATIONS IN FORCE AT THE TIME.
PARTICULAR ATTENTION MUST BE PAID TO THE FOLLOWING:

I. E. E. REGULATIONS FOR ELECTRICAL INSTALLATIONS

ELECTRICITY AT WORK REGULATIONS

HEALTH AND SAFETY AT WORK ACT

FIRE PRECAUTIONS ACT

LOCAL AND NATIONAL BUILDING REGULATIONS

USERS SHOULD BE CONVERSANT WITH APPROPRIATE PROVISIONS OF THE FIRE PRECAUTIONS ACT.
IN PARTICULAR THEY SHOULD BE AWARE OF THE NEED FOR REGULAR SERVICING BY A COMPETENT
PERSON TO ENSURE CONTINUED SAFE AND EFFICIENT APPLIANCE PERFORMANCE.

WARNING:

TO PREVENT SHOCKS, APPLIANCES WHETHER GAS OR ELECTRIC, MUST BE EARTHED.

UPON COMPLETION OF INSTALLATION, THE OWNERS MANUAL SHOULD BE HANDED TO USERS AND
THE  INSTALLER  SHOULD  INSTRUCT  RESPONSIBLE  PERSON(S)  IN  THE  CORRECT  OPERATION  AND
MAINTENANCE OF THE APPLIANCE.

THIS  EQUIPMENT  IS  ONLY  FOR  PROFESSIONAL  USE,  AND  SHALL  BE  OPERATED BY QUALIFIED
PERSONS. IT IS THE RESPONSIBILITY OF THE SUPERVISOR OR EQUIVALENT TO ENSURE THAT USERS
WEAR  PROTECTIVE  CLOTHING,  AND  TO  DRAW  ATTENTION  TO  THE  FACT THAT, SOME PARTS WILL,
BY NECESSITY, BECOME VERY HOT AND WILL CAUSE BURNS IF TOUCHED ACCIDENTALLY.

UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER ARE
NOT TO BE ADJUSTED BY THE INSTALLER.

BEFORE ATTEMPTING ANY SERVICING, ENSURE THAT THE ELECTRICAL SUPPLY IS DISCONNECTED.

WARNING:

THE  UNIT  MUST  BE INSTALLED BY PERSONNEL QUALIFIED TO WORK WITH
ELECTRICITY.  IMPROPER INSTALLATION CAN RESULT IN INJURY TO PERSONNEL
AND/OR  DAMAGE  TO  EQUIPMENT.  THE UNIT MUST BE INSTALLED IN ACCORDANCE
WITH APPLICABLE CODES.

CAUTION:

SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.

WARNING:

TO  AVOID  DAMAGE  OR  INJURY, FOLLOW THE WIRING DIAGRAM EXACTLY WHEN
CONNECTING A UNIT.

WARNING:

BEFORE  CLEANING  THE  OUTSIDE  OF  THE  KETTLE,  DISCONNECT  ELECTRIC  POWER .
KEEP WATER AND SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS.

NOTICE:

DO NOT USE ANY DE-GREASER THAT CONTAINS POTASSIUM HYDROXIDE OR SODIUM
HYDROXIDE OR THAT IS ALKALINE.

WARNING:

USE  OF  ANY  REPLACEMENT  PARTS  OTHER  THAN  THOSE  SUPPLIED  BY  GROEN  OR
THEIR  AUTHORIZED  DISTRIBUTOR  VOIDS  ALL  WARRANTIES  AND  CAN RESULT IN
BODILY  INJURY  TO  THE OPERATOR AND DAMAGE THE EQUIPMENT.  SERVICE BY
OTHER THAN FACTORY-AUTHORIZED PERSONNEL WILL VOID ALL WARRANTIES.

WARNING:

HIGH VOLTAGE EXISTS INSIDE CONTROL COMPARTMENTS. DISCONNECT FROM
BRANCH BEFORE SERVICING.  FAILURE TO DO SO CAN RESULT IN SERIOUS INJURY OR
DEATH.

CAUTION:

BE

 

SURE

 

ALL

 

OPERATORS

 

READ,

 

UNDERSTAND

 

AND

 

FOLLOW

 

THE

 

OPERATING

INSTRUCTIONS,

 

CAUTIONS,

 

AND

 

SAFETY

 

INSTRUCTIONS

 

CONTAINED

 

IN

 

THIS

 

MANUAL.

WARNING:

THIS  UNIT  IS  INTENDED  FOR  USE  IN  THE COMMERCIAL HEATING, COOKING AND
HOLDING  OF  WATER  AND FOOD PRODUCTS, PER THE INSTRUCTIONS CONTAINED IN
THIS  MANUAL.  ANY  OTHER  USE  COULD  RESULT  IN  SERIOUS PERSONAL INJURY OR
DAMAGE TO THE EQUIPMENT AND WILL VOID WARRANTY.

Содержание TDB/7

Страница 1: ...BE RETAINED FOR FUTURE REFERENCE READ UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS I...

Страница 2: ...INSTALLER BEFORE ATTEMPTING ANY SERVICING ENSURE THAT THE ELECTRICAL SUPPLY IS DISCONNECTED WARNING THE UNIT MUST BE INSTALLED BY PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY IMPROPER INSTALLATION CA...

Страница 3: ...ON STABLE FLAT SURFACE AS CLOSE TO KETTLE AS POSSIBLE 4 STAND TO LEFT OR RIGHT SIDE OF KETTLE WHILE POURING DO NOT STAND DIRECTLY IN POUR PATH OF HOT CONTENTS 5 POUR SLOWLY MAINTAIN CONTROL OF KETTLE...

Страница 4: ...TOR WARNINGS 2 EQUIPMENT DESCRIPTION 5 INSPECTION UNPACKING 7 INSTALLATION 8 INITIAL START UP 9 OPERATION 10 SEQUENCE OF OPERATION 12 MAINTENANCE 13 TROUBLESHOOTING 15 CLEANING 19 PARTS LISTS 21 SCHEM...

Страница 5: ...e kettle capacity and heated by electricity delivers steam into the jacket Airless operation of the steam jacket permits uniform efficient heating at temperatures as low as 150 F and as high as 295 F...

Страница 6: ...7 CE Model Models Optional equipment available with any model 1 Stand that supports the unit and holds a pan in position for filling 2 Lift off cover 3 Basket insert 4 Fill faucet 5 Manual stirrers fa...

Страница 7: ...hipping damage or incorrect shipments to the delivery agent Write down the model number serial number and installation date and retain this information for future reference Space for these entries is...

Страница 8: ...es and all regulations in force at the time of installation 3 The equipment is shipped ready for three phase operation Refer to the wiring diagram for single phase operation 4 Bring the electrical ser...

Страница 9: ...ition 2 Turn on the electrical service to the unit 3 Pour two to four liters of water into the kettle 4 Following To Start Kettle instructions in the Operation section of this manual begin heating the...

Страница 10: ...g The heating indicator light indicates that the kettle is heating and cycling of the light on and off indicates that the kettle is being held at the set temperature Once in each cycle the contactors...

Страница 11: ...ng of water and food products A cover helps retain heat in the cooking vessel and reduces the amount of heat and humidity released into the kitchen Use of a cover can reduce some product cook times an...

Страница 12: ...lift and safely move get help from another person Remove product immediately from basket into another container being sure to avoid contact with hot product and hot basket or g Place basket with food...

Страница 13: ...N c Test the safety valve at least twice each month Test the valve with the kettle operating at 15 psi 105 kPa by pulling up the test chain for at least five seconds Then release the chain and let the...

Страница 14: ...replacing water lost as steam use distilled water If you are replacing treated water that ran out of the jacket prepare more treated water as directed in step 3 Water Treatment Procedure b Remove fill...

Страница 15: ...not heat but heating indicator comes on Auth Service Rep Only a Contactor X b Heater elements with ohmmeter for ground short or open element If element is defective call Groen X Kettle continues heati...

Страница 16: ...if touched accidentally IMPORTANT READ FIRST IMPORTANT The Groen Steam Jacketed Kettle you have just purchased has been handcrafted from the finest materials meticulously inspected and carefully test...

Страница 17: ...acuum 20 to 30 below zero then the jacket will require venting This will require a service call f Switch the On Off switch to the On position The power on neon will illuminate g Turn the thermostat di...

Страница 18: ...open and shut off power to the elements until the kettle cools Setting the operating thermostat dial to OFF shuts down all control and heating circuits 6 To Empty Kettle TDB 7 Kettles with Crank Tilt...

Страница 19: ...EFULLY 3 Procedure a Clean food contact surfaces as soon as possible after use If the unit is in continuous use thoroughly clean and sanitize the interior and exterior at least once every 12 hours WAR...

Страница 20: ...the agent after the unit has been cleaned and drained Rinse off the sanitizer thoroughly NOTICE NEVER LEAVE A CHLORINE SANITIZER IN CONTACT WITH STAINLESS STEEL SURFACES LONGER THAN 30 MINUTES LONGER...

Страница 21: ...CE 21 Parts List Kettle Body Pull Tilt Model To order parts contact your Groen Certified Service Agency Supply the model designation part description part number quantity and where applicable voltage...

Страница 22: ...OM SM TDB 7 CE 22 Replacement Parts List Pull Tilt Models...

Страница 23: ...OM SM TDB 7 CE 23 Replacement Parts List Crank Tilt Models...

Страница 24: ...ear bushing 113055 x 49 Safety Valve 097005 x x 15 Set screw socket 3 8 16 x 1 005593 x 50 Pressure gauge 084208 x x 16 Gear sector 12 DP 009829 x 50a Pressure gauge lens 087635 x x 17 Key 1 4 sq x 1...

Страница 25: ...OM SM TDB 7 CE 25 Wiring Diagram...

Страница 26: ...____________ Date Service Performed Performed By References KLENZADE SALES CENTER ECOLAB Inc 370 Wabasha St Paul Minnesota 55102 800 352 5326 or 612 293 2233 NATIONAL FIRE PROTECTION ASSOCIATION 60 Ba...

Страница 27: ...ponents found to be defective during the warranty period IV This warranty does not cover boiler maintenance calibration or periodic adjustments as specified in operating instructions or manuals and co...

Страница 28: ...1055 Mendell Davis Drive Jackson MS 39272 Telephone 601 373 3903 Fax 601 373 9587 OM SM TDB 7 CE Part Number 128433 Revised 7 99...