background image

Model T10006 50 Kg Digital Crane Scale

-10

-

BATTERY  MUST  BE  RECYCLED  OR  DISPOSED 
OF  PROPERLY.

  Consult  your  local  disposal  com-

pany for recycling options in your area.

SECTION 5: MAINTENANCE

!

Always DISCONNECT POWER before 
servicing,  adjusting,  or  doing  main-
tenance  to  reduce  the  risk  of  acci-
dental injury or electrocution.

Regularly  check  mounting  hardware  for 
cracks,  unsafe  wear,  deformation,  or 
warping.  DO  NOT  attempt  to  fix  these 
items!  Discard  and  replace  all  damaged 
hardware. Regularly check for loose pins, 
rings, screws, and safety latches. Tighten 
or  replace  any  loose  items.  Damaged  or 
loose parts may cause the load to fall and 
may result in serious injury.

Always keep the scale in a hanging posi-
tion to relieve strain on the load cell. Never 
leave a load or weighing equipment on the 
scale  when  not  in  use.  This  may  cause 
excessive strain on the precision weighing 
device and may result in inaccurate read-
ings and shorten the life of your scale.

When re-charging the scale battery, charge 
for  at  least  8  hours.  Excessive  charging 
will not damage the battery. Batteries must 
be recycled or disposed of properly.

If  your  scale  malfunctions  permanently, 
do not attempt to fix it yourself. Contact a 
certified  professional  for  any  electrical  or 
detailed calibration work.

General

If  the  scale  becomes  dirty,  clean  the 
screen with a soft cloth using a mild win-
dow  cleaner  or  detergent.  Avoid  using 
paper  towels.  DO  NOT  use  solvents, 
chemicals  or  other  corrosive  materials  to 
clean the scale.

If the scale will not be used for a prolonged 
amount of time, remove the battery. Hang 
the scale at all times and do not allow it to 
rest on the ground.

Содержание T10006

Страница 1: ...RIZZLY INDUSTRIAL INC WARNING NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL INC JM9992 PRINTED IN CHINA MODEL T10006 50 Kg DIGITAL...

Страница 2: ...member that safety messages by themselves do not eliminate danger and are not a substitute for proper accident prevention measures Indicates a potentially hazardous situation which if not avoided MAY...

Страница 3: ...OR NEAR A PERSON Loads may fall at any given time due to overloading improper load ing procedures or failure of a com ponent 8 ALWAYS DISCONNECT FROM POWER SOURCE BEFORE SERVICING Make sure switch is...

Страница 4: ...midity 85 or Less Remote Control Battery 5 1 5Vx2 Digital Display 5 Digit LCD LED Character Display 30mm High Scale Body Die Cast Aluminum Case Scale Weight 10 35 lbs Machine Data If you have any comm...

Страница 5: ...the maximum loading capacity as well as any possible overloading that may occur Working Clearances Consider existing and anticipated needs dimensions of your weighing platform size of material to be p...

Страница 6: ...time Loading Hardware When attaching your crane scale 1 DO NOT use multiple chains or har nesses Only one point of contact should be used on the hook and shack le to lessen the chance of the load fal...

Страница 7: ...on The tare function will allow you to auto matically deduct the weight of the weigh ing platforms or containers resulting in a final weight of only the items that you want weighed the net weight When...

Страница 8: ...maximum capacity net tare weight OL will be displayed on the screen DO NOT overload the scale Failure to stay below the maximum load rating may result in injury damage the scale and void your warrant...

Страница 9: ...will display SHIFT Press the button on the remote control to display the current zero value Advance Tare Weight To input a known tare weight before weigh ing an item press MR and the screen will disp...

Страница 10: ...ld press HOLD to exit Brightness F1 1 through 5 1 lowest 5 highet setting Note The remote control is a generic remote and may contain buttons that will not be used with this particular model Should yo...

Страница 11: ...rain on the load cell Never leave a load or weighing equipment on the scale when not in use This may cause excessive strain on the precision weighing device and may result in inaccurate read ings and...

Страница 12: ...indicator light will not turn ON 1 Damaged adaptor 2 The adaptor is not fully plugged into the scale or out let 1 Check or replace the adap tor 2 Insert the plug again Scale unable to tare 1 Damaged T...

Страница 13: ...SCR M3 5 X 4 7 PT10006007 BACK PANEL WIRE ASSEMBLY 24 PT10006024 THREE WIRE ASSEMBLY 8 PLW09M LOCK WASHER 3MM 25 PT10006025 GRVD HDLESS CLEVIS PIN 12 X 40 9 PS79M PHLP HD SCR M3 5 X 8 26 PW06M FLAT W...

Страница 14: ...injuries to persons or property or for incidental contingent special or consequential damages arising from the use of our products To take advantage of this warranty contact us by mail or phone and g...

Страница 15: ......

Страница 16: ......

Отзывы: