H8371 Power Feed for Knee Mills

Figure 2.

 Power feed system.

A.  Limit  Switch: 

Stops  powered  table  move-

ment when either limit stop presses a plunger 
on the switch.

B.  Limit Stop: 

Activates the limit switch. Secure 

these devices along the table to set the range 
of movement.

C.

 

Rapid  Movement  Button: 

Moves  the  table 

at the maximum speed in the direction select-
ed.

D.

 

Direction Lever: 

Starts, reverses, and stops 

longitudinal table movement.

E.  Speed Dial: 

Controls the speed that the table 

moves—turn  the  dial  clockwise  to  increase 
the speed.

F.  Reset  Button:

  When  a  current  over  3.5 

amps passes through the unit for more than 
10 seconds, the internal circuit switch will cut 
the power to the unit. Investigate and resolve 
any  problems,  then  use  this  button  to  reset 
the internal circuit switch.

G.  ON/OFF  Switch: 

The  master  power  switch 

for the power feed.

H.  Power Lamp: 

Lights when the power feed is 

turned 

ON

.

Functional Overview

The  Model  H8371  power  feed  is  designed  to 
install on the right side of a knee mill table to pro-
vide powered longitudinal movement of the table. 
Refer  to 

Figure  2

  and  the  descriptions  below  to 

become  familiar  with  the  functional  parts  of  the 
power feed system.

Installation

1.

  DISCONNECT THE MILL FROM POWER!

 

Note: 

During the next step, take care not to 

misplace the leadscrew keys.

2.

  Remove  the  handle  and  graduated  dial 

assemblies from the right side of the longitu-
dinal (X-axis) leadscrew.

3.

  Determine  if  there  is  adequate  support  on 

the mill to mount the power feed unit onto the 
leadscrew.

— If  adequate  mounting  for  the  power  feed 

unit exists at the end of the leadscrew, you 
do  not  need  to  use  the  optional  mounting 
bracket. Continue with 

Step 4

.

— If  there  is  not  adequate  mounting  for  the 

power  feed  unit,  you  will  need  to  use  the 
provided  mounting  bracket.  Proceed  to 

Using the Mounting Bracket

 on 

Page 4

.

4.

  Make  sure  the  leadscrew  is  clean  of  debris 

and  oil,  then  slide  the  power  feed  unit  onto 
the  leadscrew  and  up  against  the  mill,  as 
shown in 

Figure 3

.

Figure 3.

 Power feed unit mounted on the 

leadscrew.

Spacers

Leadscrew

Keys

Cap Screws

 

Note: 

Use the spacers provided where nec-

essary  to  ensure  that  the  parts  installed  on 
the  leadscrew  stay  snug  up  against  one 
another.

Содержание H8371

Страница 1: ...2 20 1 Cap Screws 1 4 20 x 1 2 Roll Pins 5 1 x 14mm 2 Phillips Head Screws 10 24 x 3 8 2 Flat Washers 5mm 2 Cable Clamps 2 Tie Wraps 2 If any nonproprietary parts are missing e g a washer or a spacer we will gladly replace them or for the sake of expediency replacements can be obtained at your local hardware store If you need help with your new power feed call our Tech Support at 570 546 9663 REF ...

Страница 2: ...e mill table to pro vide powered longitudinal movement of the table Refer to Figure 2 and the descriptions below to become familiar with the functional parts of the power feed system Installation 1 DISCONNECT THE MILL FROM POWER Note During the next step take care not to misplace the leadscrew keys 2 Remove the handle and graduated dial assemblies from the right side of the longitu dinal X axis le...

Страница 3: ...ear installed onto the leadscrew Brass Bevel Gear 8 Re install the graduated dial and handle assemblies Electrocution or fire could result if machine is not grounded and installed in compliance with electrical codes Compliance MUST be verified by a qualified electrician 10 Position and mount the limit switch in the center of the saddle as shown in Figure 5 so that the plungers on the sides of the ...

Страница 4: ...alled on the leadscrew stay snug up against one another 3 Remove the assembly drill and tap the mounting holes re install the power feed assembly onto the leadscrew then secure the mounting bracket to the table see Figure 7 Maintenance Clean and lubricate the power feed gearing every three months of normal use To clean and lubricate the power feed gear ing 1 DISCONNECT THE MILL AND POWER FEED FROM...

Отзывы: