h8243 120V/240V on/oFF paddle switch

disabling & locking switch

figure 3.

 switch disabled by a padlock.

The switch can be disabled and locked by insert-
ing a padlock through the ON/START button, as 
shown.  Locking  the  switch  in  this  manner  can 
prevent  unauthorized  operation  of  the  machine, 
which is especially important if the machine is not 
stored inside an access-restricted building.

IMPORTANT: Locking the switch with a padlock 
only  restricts  its  function.  It  is  not  a  substitute 
for  disconnecting  power  from  the  machine  when 
adjusting or servicing.

Shaft

Padlock

ON

 

/

 

START

Button

OFF

 

/

 

STOP

Paddle

figure 4.

 Minimum lock shaft requirements.

NOTICE

The padlock shaft diameter is important to 

the  disabling  function  of  the  switch.  With 

any  padlock  used  to  lock  the  switch,  test 

the switch after installation to ensure that it 

is properly disabled.  

Children  or  untrained  people  can  be  killed 

or  seriously  injured  by  this  machine.  This 

risk increases with unsupervised operation. 

To  help  prevent  unsupervised  operation, 

disable  and  lock  the  switch  before  leaving 

machine  unattended!  Place  key  in  a  well-

hidden or secure location.

Load

Line

KEDU

HY56

Rear View

of Switch

Hot
Out

Hot

In

Machine

Out

120V Neutral

or 240V Hot

In

120V Neutral

or 240V Hot

Verified

Ground*

Power Source

figure 2.

 h8243 wiring diagram.

installation

When installing the h8243 switch, use the wiring 
diagram  in 

figure  2

  to  ensure  proper  wire  con-

nections.

this switch is intended to be connected to 

stranded wire with insulated crimp-type ring 

wire terminals. 

all crimps must be "pull-checked" to ensure 

that  wires  are  securely  crimped  and  will 

not fall out with moderate tension or when 

exposed to normal machine vibration.

*the  machine  MUst  be  connected  to  a  verified 
ground.  in  the  event  of  certain  malfunctions  or 
breakdowns, grounding reduces the risk of elec-
tric shock by providing a path of least resistance 
for electric current.